Lufft 8160.UANA User manual

Operating Manual UMB Analogue/Digital Converter ANACON
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1
Operating Manual
UMB Analogue/Digital Converter ANACON
Order Number: 8160.UANA
Status: V6; 1425.03.2010

UMB Analogue/Digital Converter ANACON Operating Manual
2 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
TABLE OF CONTENTS
PLEASE READ BEFORE USE..............................................................................................3
DESCRIPTION..................................................................................................................5
ANACON UMB ANALOGUE/DIGITAL CONVERTER............................................................6
CONFIGURATION ...........................................................................................................10
INSTALLATION AND COMMISSIONING...............................................................................11
SENSOR CHANNEL LIST.................................................................................................13
TECHNICAL DATA ..........................................................................................................16
MAINTENANCE AND CARE..............................................................................................20
DISPOSAL.....................................................................................................................20
MANUFACTURER...........................................................................................................20
EC CERTIFICATE OF CONFORMITY.................................................................................21
Version history:
Version
Date
Compiled by
Comments
V1
15.09.2006
EES/SH
First edition
V2
11.01.2007
EES
Sensor connection scheme for wind sensor changed; additional channels for wind speed in knots supplemented
V3
27.03.2007
EES
EC Certificate of Conformity and channels for abs. air pressure / humidity supplemented; grounded DIN rail
V4
09.10.2007
EES
Channel list for precipitation and pulses changed
V5
13.07.2009
EES
Channel list for 2nd Temperature channel added
V6
25.03.2010
FS
New Housing

Operating Manual UMB Analogue/Digital Converter ANACON
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 3
Please read before use
Before using the equipment, please read the operating manual carefully and follow the instructions in every
detail.
Safety instructions
Installation and commissioning must only be carried out by suitably qualified specialist personnel.
Never take measurements on or touch live electrical parts.
Only mount the module on the DIN rail when the power is switched off.
Protect the device from direct sunlight
The equipment requires an adjustment period of several minutes on being moved to a
location with different climate conditions.
Pay attention to the technical data and storage and operating conditions.
Designated use
The equipment must only be operated within the range of the specified technical data.
The equipment must only be used under the conditions and for the purposes for which it was designed.
The safety and operation of the equipment can no longer be guaranteed if it is modified or adapted.
Guarantee
The guarantee period is 24 months from the date of delivery. The guarantee is forfeited if the designated use is
violated.

UMB Analogue/Digital Converter ANACON Operating Manual
4 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Symbols used
Important indication concerning possible hazards to the user
Important indication for the correct functioning of the device

Operating Manual UMB Analogue/Digital Converter ANACON
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 5
Description
The UMB Analogue/Digital Converter (ANACON) is an intelligent analogue/digital converter with electrical
isolation, suitable for integration into UMB networks. The devices are easily installed on standard EN mounting
rails and networked together by means of mounting rail bus connectors. The 24V feed for the power supply
takes place via the bus connector. Windows software is available for the configuration of the ANACON via
RS232 port and an additional ISOCON (8160.UISO).
Features
2 analogue inputs with 24 bit resolution and signal conditioning for resistance, PT100/PT1000, voltage,
current, frequency and pulses as well as pre-defined settings for a large number of Lufft environmental
sensors. A half-duplex RS485 interface for networking the converters together.
Easy mounting on standard EN mounting rails
Easy networking of up to 32 subscribers via mounting rail bus connectors
24V DC power supply suitable for switchgear cabinets
ESD protection for all interfaces
Configuration via Windows software provided
Functions displayed via LED’s
Low space requirement; width approx. 23mm/module
Low energy consumption / dissipation

UMB Analogue/Digital Converter ANACON Operating Manual
6 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
ANACON UMB Analogue/Digital Converter
Summary
Status LED’s
Input Channel B
Input Channel A
Power supply & RS485 bus
interface

Operating Manual UMB Analogue/Digital Converter ANACON
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 7
Analogue Inputs Channel A and Channel B
ANACON-UMB
Connection
Channel B
Channel A
PIN
Name
1
Power, Sensor Power Supply
2
ANA_+, Sense High Input
3
ANA_I, Force Low Input
4
ANA_-, Force High Input

UMB Analogue/Digital Converter ANACON Operating Manual
8 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Mounting Rail Bus Connector
NOTE: The assembly must take place on a grounded DIN rail !
Earth 24V Power Supply, Feed
Earth 24V Power Supply, Feed
+24V Power Supply, Feed
B1, Internal Bus
A1, Internal Bus

Operating Manual UMB Analogue/Digital Converter ANACON
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 9
Status LED’s
There are 2 LED’s on the front side of the device in order to display the correct configuration and functioning of
the ANACON. Their meanings are as follows:
Red LED: - If this LED lights up permanently after switch-on there is a configuration fault.
- If this LED lights up during operation an unforeseen fault has occurred; the device must be
reset.
Green LED: - This LED flashes briefly (20ms) every 10 seconds to display the function of the device.
- This LED lights up for a longer period (>500ms) during measurement.

UMB Analogue/Digital Converter ANACON Operating Manual
10 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Configuration
The ANACON modules are all supplied from the factory with ID 1. If several modules are installed in a UMB
network, it must be ensured that all modules on the network have a different ID. The following steps should be
taken in order to configure the device:
1. Clip a mounting rail bus connector onto the Din rail and connect the 24V supply with the aid of the
connector provided. Please ensure that the polarity and pin assignment are correct on connection.
Incorrect connection can cause the destruction of the ANACON module!
2. Next mount the ANACON module which you wish to configure.
3. For the connection to the RS232 port of your PC a additional ISOCON (8160.UISO) is necessary. Clip
the ISOCON also on the mounting rail and connect the module to your PC via the RS232 interface.
4. Set the desired ID and channel configuration using the UMB-Config-Tool software. You can enter the
configured ID in the inscription field on the front side of the module.
5. The ANACON is now ready for operation and can be detached from the DIN rail. Please repeat steps 2
to 5 for all additional ANACON modules.