LSIS Starvert iG5A Series User manual

0.4~1.5kW 1phase 200~230Volts
0.4~22kW 3Phase 200~230Volts
0.4~22kW 3Phase 380~480Volts
iG5A
www.lsis.com
Compact & Powerful Drive

LS Starvert iG5A is very competitive in its price and shows an upgraded functional strength.
User-friendly interface, extended drive ranges up to 22kW,
superb torque competence and small size of iG5A provides an optimum use environment.
Drive
STARVERT iG5A
Standard
compliance
High
performance
Compactness
User-
friendliness
& Easy
maintenance
iG5A
2

Overview
Model & Type
Standard Specifications
Wiring
Terminal Configurations
Keypad Features
Parameter Setting
Trial Run
Dimensions
Braking Resistors and Peripheral Devices
Function List
Protective Functions
Fault Remedy
4
8
9
11
13
15
16
18
20
23
25
42
43
Compact & Powerful Drive iG5A
Drive Starvert iG5A Series
Contents
3

Condition:
Speed vs Torque Characteristics
Speed (Hz)
Torque (%)
Sensorless Vector Control Mode: Auto tuning Measure maximum
torque (%) at each speed (1/5/10/20/30/40/50/60Hz)
+10
-10
Speed
Time
With braking resistor
Reducing
deceleration time
Normal state
iG5A
Powerful & Upgraded Performance
Sensorless vector control
Ground-fault protection
during running
Analog control from -10V to 10V
Forward
PID controlPID control
Pl controlPI control
Reverse
Built-in PID control
Built-in dynamic braking circuit
Built-in 485 communication
Wide product range
The built-in sensorless vector control provides
the superb speed control and powerful high
torque.
The ground-fault protection of output terminal
is possible during running.
Inputting analog signals from -10V to 10V
provides user-friendly operation.
The built-in PID function enables to control
flow-rate, oil-pressure, temperature, etc
without any extra controller.
The built-in dynamic braking circuit minimizes
deceleration time via braking resistors.
The built-in RS-485 communication supports
remote control and monitoring between iG5A
and other equipment.
iG5A consists of the product range from 0.4 to 22KW.
iG5A provides sensorless vector control, PID control,
and ground-fault protection through powerful built-in functions.
4

Checking operation status
(Voltage, Current, Frequency, etc)
Checking modified parameters
Windows support
Monitoring
Connected to PC
Connected to XGT panel
Checking operation time
Automatic list-up of trip record
Language support (Korean, English, Chinese)
Monitoring
Convenient remote control to modify operation status
(Forward/Reverse operation, Frequency, etc)
Easy parameter setting
Available to control up to 31 Drives
RS-485, Modbus communication
Remote Control
Convenient remote control to modify operation status
(Forward/Reverse operation, Frequency, etc)
Easy parameter setting
Available to control up to 31 Drives
RS-485, Modbus communication
Remote Control
RS-485
-
232C converter
RS-485 communication
5
Compact & Powerful Drive iG5A
Drive Starvert iG5A Series

iG5A
User-friendly Interface & Easy Maintenance
The parameter setting becomes easier by adopting the 4 directions key. And iG5A supports
easy maintenance via diagnosis and fan changeable structure.
Diagnosis of output module
Easy change of fan
Cooling fan control
User-friendly interface
External loader (Optional)
Through easy parameter setting, iG5A can diagnose the
status of output module.
iG5A is designed to be the fan changeable structure in
preparation for a fan breakdown.
By controlling the cooling fan, iG5A provides a virtually
quiet environment according to the status of operation.
The 4 directions key provides easy handling and
monitoring.
Loader type + External type (Optional)
The external loader away from a panel enables to control
and monitor conveniently. And the parameters made by
external loader can be copied and applicable to other
Drives.
Model name
INV, REMOTE KPD 2M (SV-iG5A)
INV, REMOTE KPD 3M (SV-iG5A)
INV, REMOTE KPD 5M (SV-iG5A)
Remarks
2m
3m
5m
6

Compact Size
The compact size achieves cost-efficiency and various applications.
Same height from 0.4 to 4.0kW (128mm)
Global standard
PNP/NPN input
iG5A series complies with CE and UL standards.
Both PNP and NPN inputs become possible and these enable to
use the outer power.
To do so, users will be given wider choices of selecting the
controller.
Global standard compliance
CE UL
7
Compact & Powerful Drive iG5A
Drive Starvert iG5A Series

iG5A
Model & Type
Applicable motor ranges
1 Phase 200V 3 Phase 200V 3 Phase 400V
0.4kW (0.5HP)
0.75kW (1HP)
1.5kW (2HP)
2.2kW (3HP)
3.7kW (5HP)
4.0kW (5.4HP)
5.5kW (7.5HP)
7.5kW (10HP)
11.0kW (15HP)
15.0kW (20HP)
18.5kW (25HP)
22.0kW (30HP)
SV004iG5A-1
SV008iG5A-1
SV015iG5A-1
SV004iG5A-2
SV008iG5A-2
SV015iG5A-2
SV022iG5A-2
SV037iG5A-2
SV040iG5A-2
SV055iG5A-2
SV075iG5A-2
SV110iG5A-2
SV150iG5A-2
SV185iG5A-2
SV220iG5A-2
SV004iG5A-4
SV008iG5A-4
SV015iG5A-4
SV022iG5A-4
SV037iG5A-4
SV040iG5A-4
SV055iG5A-4
SV075iG5A-4
SV110iG5A-4
SV150iG5A-4
SV185iG5A-4
SV220iG5A-4
SV
STARVERT
iG5A series
Motor rating (kW)
(004: 0.4kW~220: 22kW)
Input voltage
(1: 1 phase 200~230[V], 2: 3 phase 200~230[V], 4: 3 phase 380~480[V])
015 iG5A 2
8

SV iG5A-1
5)
4)
Max.
capacity
1)
(HP)
(kW)
Output
rating
Capacity (kVA)
FLA (A)
Max frequency
Max voltage
Rated voltage
Rated frequency
Cooling method
Weight (kg)
Input
rating
1) Indicate the maximum applicable motor capacity when using 4 pole LS standard motor.
2) Rated capacity is based on 220V for 200V series and 440V for 400V series.
3) Refer to 15-3 of userʼs manual when carrier frequency setting (39) is above 3kHz.
4) Max. frequency setting range is extended to 300Hz when H40 (Control mode select) is set to 3 (Sensorless vector control).
5) Max. output voltage cannot be higher than the input voltage. It can be programmable below input voltage.
6) Self-Cooling
2)
3)
015008004
2
1.5
3.0
8
1.84
1
0.75
1.9
5
1.12
0.5
0.4
0.95
2.5
0.76
400 [Hz]
3 phase 200~230V
1phase 200~230 VAC (+10%, -15%)
50~60 [Hz] (±5%)
Forced air cooling
SV iG5A-2
5)
4)
Max.
capacity
1)
(HP)
(kW)
Output
rating
Capacity (kVA)
FLA (A)
Max frequency
Max voltage
Rated voltage
Rated frequency
Cooling method
Weight (kg)
Input
rating
2)
3)
004 008 015 022 037 040 055 075 110 150 185 220
0.5
0.4
0.95
2.5
0.76
1
0.75
1.9
5
0.77
2
1.5
3.0
8
1.12
3
2.2
4.5
12
1.84
5
3.7
6.1
16
1.89
5.4
4.0
6.5
17
1.89
7.5
5.5
9.1
24
3.66
10
7.5
12.2
32
3.66
15
11
17.5
46
9.0
20
15
22.9
60
9.0
25
18.5
28.2
74
13.3
30
22
33.5
88
13.3
400 [Hz]
3 phase 200~230V
3 phase 200~230 (+10%, -15%)
50~60 [Hz] (±5%)
Forced air coolingN/C
6)
SV iG5A-4
5)
4)
Max.
capacity
1)
(HP)
(kW)
Output
rating
Capacity (kVA)
FLA (A)
Max frequency
Max voltage
Rated voltage
Rated frequency
Cooling method
Weight (kg)
Input
rating
2)
3)
004 008 015 022 037 040 055 075 110 150 185 220
0.5
0.4
0.95
1.25
0.76
1
0.75
1.9
2.5
0.77
2
1.5
3.0
4
1.12
3
2.2
4.5
6
1.84
5
3.7
6.1
8
1.89
5.4
4.0
6.5
9
1.89
7.5
5.5
9.1
12
3.66
10
7.5
12.2
16
3.66
15
11
18.3
24
9.0
20
15
22.9
30
9.0
25
18.5
29.7
39
13.3
30
22
34.3
45
13.3
400 [Hz]
3 phase 380~480V
3 phase 380~480 VAC (+10%, -15%)
50~60 [Hz] (±5%)
Forced air coolingN/C
6)
Standard Specifications
1 Phase 200V
3 Phase 200V
3 Phase 400V
9
Compact & Powerful Drive iG5A
Drive Starvert iG5A Series

1) Means average braking torque during Decel to stop of a motor.
2) Refer to Chapter 16 of userʼs manual for DB resistor specification.
Over voltage, Under voltage, Over current, Ground fault current detection, Drive overheat,
Motor overheat, Output phase open, Overload protection, Communication error,
Loss of speed command, Hardware fault, Fan trip
V/F, Sensorless vector control
Linear, Squared, User V/F
150% per 1 min.
Manual/Auto torque boost
20%
150% when using optional DB resistor
Digital command: 0.01Hz
Analog command: 0.06Hz (Max. freq.: 60Hz)
Digital command: 0.01% of Max. output frequency
Analog command: 0.1% of Max. output frequency
Trip
Alarm
Momentary power loss
Operation mode
Frequency setting
Operation features
Dynamic
braking
Input
Output
Max. braking
torque
Max. Duty
Open collector
terminal
Multi-function relay
Analog output (AM)
IP 20, NEMA1 (Optional)
-10℃~50℃
-20℃~65℃
Below 90% RH (No condensation)
Below 1,000m, 5.9m/sec2(0.6G)
70~106 kPa
Protected from corrosive gas, Combustible gas, Oil mist or dust
1)
2)
Keypad/ Terminal/ Communication option/ Remote keypad selectable
PID, Up-down, 3-wire
NPN/PNP selectable
0~10Vdc (less than 10mA): Output freq, Output current, Output voltage, DC link selectable
FWD/REV RUN, Emergency stop, Fault reset, Jog operation, Multi-step Frequency-High, Mid, Low,
Multi-step Accel/Decel-High, Mid, Low, DC braking at stop, 2nd motor select, Frequency UP/Down,
3-wire operation, External trip A, B, PID-Drive (V/F) operation bypass,
Option-drive (V/F) operation bypass, Analog Hold, Accel/Decel stop
Analog: 0~10V, -10~10V, 0~20mA
Digital: Keypad
Fault output and
drive status output
Less than DC 24V, 50mA
(N.O., N.C.) Less than AC 250V, 1A; Less than DC 30V, 1A
Stall prevention, Overload
Below 15 msec.: Continuous operation (Should be within rated input voltage, rated output power.)
Above 15 msec.: Auto restart enable
Protection degree
Ambient temp
Storage temp
Humidity
Altitude/Vibration
Atmospheric pressure
Location
Control method
Frequency setting resolution
Frequency accuracy
V/F pattern
Overload capacity
Torque boost
Multi-function
terminal
P1~P8
Environ
ment
Control
Protective
function
Operation
iG5A
Standard Specifications
10
Other manuals for Starvert iG5A Series
1
This manual suits for next models
27
Table of contents
Other LSIS DC Drive manuals

LSIS
LSIS G100 User guide

LSIS
LSIS SV-iS7 series User manual

LSIS
LSIS SV-iS7 series User manual

LSIS
LSIS SV008iC5-1F User manual

LSIS
LSIS iS7 Series Use and care manual

LSIS
LSIS S100 Series User manual

LSIS
LSIS LSLV-H100 User manual

LSIS
LSIS S100 Series User manual

LSIS
LSIS S100 Series User manual

LSIS
LSIS H100 User manual
Popular DC Drive manuals by other brands

ABB
ABB RSYC-01 user manual

Rockwell Automation
Rockwell Automation PowerFlex 700S Programming manual

WEG
WEG DeviceNet CFW500 user manual

Siemens
Siemens SINAMICS G List manual

Siemens
Siemens SINAMICS SM150 6SL3815-7NP41-0AA1 Operating instructions & installation instructions

SOMFY
SOMFY JR RU 30 instructions