logitrans WSP 2200 User manual

WSP 2200 Weighing scale pallet truck
Quick guide

S1056
1
Contents
5.5 Operation.........................................................................................................2
6.0 Battery and charger.........................................................................................3
10.2 Actual battery voltage...............................................................................3
5.4 Starting up scale..............................................................................................3
8.2 Display and Keypad........................................................................................4
Choice ”Set point indication” ...........................................................................4
8.3 Keypad ............................................................................................................5
10.1 Backlight of display..................................................................................6
9.0 Program shift / Choice....................................................................................7
8.4 How to use ......................................................................................................8
Tara ...................................................................................................................8
Pretara ...............................................................................................................8
Gross/Net switching..........................................................................................8
9.1 Simple count function.....................................................................................9
9.2 Target weight function..................................................................................10
9.3 Accumulation function..................................................................................11
ACC 1. First lift ..............................................................................................11
ACC 1. Subsequent lifts..................................................................................11
ACC 2. Automatic addition function..............................................................12
ACC 2. First lift ..............................................................................................12
ACC 2. Subsequent lifts..................................................................................12
11 Error messages...............................................................................................13
*The figures refer to the User Guide

S1056
2
5.5 Operation
The weighing scale pallet truck has to be placed on an even surface.
The load centre of the load has to be centred on the forks and, if possible, placed
towards the vertical flat iron (if placed on a EURO pallet).
Do NOT leave the load on the forks for longer periods (e.g. overnight), as this
can influence the effectiveness of the weighing cells.

S1056
3
6.0 Battery and charger
Up to 250 operating hours per charging.
Battery indicator indicates whether the battery voltage is low.
Press for 1-2 seconds, and the actual battery voltage will be visible.
10.2 Actual battery voltage
Press for 2 seconds.
On the display, you see the actual battery voltage
After 3 seconds, normal weighing mode will be shown.
5.4 Starting up scale
Press On/Off (B). The scale is on and the self-
acting display test will begin. This is visible
through counting on the display from 88888 to
00000. When displaying 0(zero), the scale is
ready to use.
If the scale does not show 0without load, reset
the display by pressing (A).
Weighing area from 2 kg to maximum load of 2,200 kg. Do not overload scale.
Scale weighs in kilograms (1,0 kg). E.g. 25,6 to 26,5 kg will be shown as 26 kg.
Charger connected. LED is red
Battery is being charged
Charger connected. LED is green
Battery is minimum 75% charged.
See the User Guide for detailed
information
A
B

S1056
4
8.2 Display and Keypad
Arrow
Display
Explanation
The scale is in the zero position. Reset scale
STABLE
The weight is stable (no change of weight)
Net
Shows net weight (tara activated)
GROSS
Shows gross weight
M+
Contents in memory
Battery voltage is too low
PT
Tara is entered (Pretara)
kg
Showing weight in kilogram
Pcs
Number of pieces
Choice ”Set point indication”
LED
Display
Setting area
Area
Values
HI
Weight higher than high limit
setting
HI
2nd value
OK
Weight between HI and LO
setting
HI & LO
2nd and 1st
value
LO
Weight lower than low limit
setting
LO
1st value

S1056
5
8.3 Keypad
Key
Explanation
Print (this model has no printer)
Sum / Result
Enter
Modus selection / Switching between programs
Switching between net and gross weight
Scroll to the left
Not in use
Switch between weight / number of units
Counting down (9-0)
Tara
Pretara
Scroll to the right
Reset weight
Counting up (0-9)

S1056
6
10.1 Backlight of display
The backlight can be set according to need.
bl.Auto Backlight automatically set, when the scale is used
bl.on Backlight switched on constantly
bl. off Backlight switched off constantly
Press for 2 seconds.
Press again
Actual settings are shown
Scroll in the menu
Exit and save by pressing After this
Enter

S1056
7
9.0 Program shift / Choice
Use this button to shift between the different programs. Each press shifts to next
picture.

S1056
8
8.4 How to use
Tara
If the scale only has to display the weight of e.g. contents of a container, place
an empty container/pallet on the scale and press .Now the scale shows 0 kg.
The display shows the symbol NET. After filling in the contents, only the
contents of the container/pallet are shown.
➢It is possible to carry through Tara several times.
➢Partial Tara removal is possible.
Remove Tara: Remove weight from forks and press
The symbol 0 kg will be shown in the display.
Pretara
Enter the weight by using the cursor function
(0~9) (9~0) To confirm.
Remove Pretara: Remove weight from forks and press
Gross/Net switching
To see total weight of the container and the content, press . Now the symbol
▼GROSS is shown, and total weight is displayed. Press again, and the
weight of the contents and the symbol NET are shown.

S1056
9
9.1 Simple count function
1. Scroll and select reference number.
Use to scroll in menu.
2. Place the reference number on the
scale
E.g. 10 units. Lift / press
3. Scale is ready to count
4. Place units, lift / press
Total weight is shown, then
unit weight and then number.
.
▼1
→0←
.
▼1
→0←
▼1
→0←
N Number
Total weight
Unit weight
(10, 20, 50, 100, 200)
Other manuals for WSP 2200
1
Table of contents
Other logitrans Truck manuals