LMI Excel XR Series User manual

Excel™XR Series
Electronic Metering Pump
Installation & Operation Manual (Enhanced Control)
Manual No.:
54772
Revision : 01
Rev. Date: 07/2016
Note: This manual is a supplement to 54630


Table of Contents
1.0 Precautions........................................................................................1
2.0 Introduction........................................................................................4
3.0 Icons ...................................................................................................4
4.0 Enhanced Control Operation............................................................6
4.1 Analog Mode...................................................................................................6
4.2 Pulse Mode.....................................................................................................7
4.3 Batch Mode.....................................................................................................9
4.4 Cycle Timer...................................................................................................10
4.5 Timed Event Mode........................................................................................12
4.6 Enhanced Control Inputs and Outputs..........................................................13
4.6.1 Inputs....................................................................................................14
4.6.1.1 Remote Internal/External Mode..................................................14
4.6.1.2 Analog Tank Level Input............................................................. 15
4.6.1.3 Configuring Enhanced Control Inputs......................................... 15
4.6.2 Outputs .................................................................................................16
4.6.2.1 Stroke Pulse...............................................................................17
4.6.2.2 Pump Running............................................................................ 17
4.6.2.3 Pump Standby............................................................................ 17
4.6.2.4 Alarm Out................................................................................... 17
4.6.2.5 Internal/External Mode ...............................................................17
4.6.2.6 User Alarm Out........................................................................... 18
4.6.2.7 Pump Stopped............................................................................ 19
4.6.2.8 Timed Event............................................................................... 19
4.6.2.9 Flow............................................................................................ 19
4.6.2.10Mirror Input AI1........................................................................... 19
4.6.2.11Configuring Enhanced Control Outputs......................................19
5.0 Cable Wiring.....................................................................................20
6.0 Troubleshooting ..............................................................................23

Table of Figures
Figure 1: Analog Mode Home Screen.............................................................................6
Figure 2: Analog Adjust...................................................................................................6
Figure 3: Pulse Mode Home Screen ...............................................................................8
Figure 4: Pulse Adjust.....................................................................................................8
Figure 5: Batch Mode Home Screen...............................................................................9
Figure 6: Batch Adjust...................................................................................................10
Figure 7: Cycle Timer Home Screen.............................................................................11
Figure 8: Cycle Timer Adjust.........................................................................................11
Figure 9: Timed Event Home Screen............................................................................12
Figure 10: Timed Event Adjust......................................................................................13
Figure 11: Int/Ext Select................................................................................................15
Figure 12: Configure Input.............................................................................................16
Figure 13: Alarm Set .....................................................................................................18
Figure 14: Configure Output..........................................................................................19
Figure 15: Cable Wiring Diagram..................................................................................20
Figure 16: Input Diagram for Digital Inputs DI1 - DI4 ....................................................21
Figure 17: Output Diagram for Digital Outputs DO1 – DO2...........................................21
Figure 18: Input Diagram for Analog 0-20mA Inputs AI1 - AI2......................................22
Figure 19: Output Diagram for Analog 4-20mA Output AO1.........................................22

PRECAUTIONS
1
1.0 Precautions
The following precautions should be taken when working with LMI metering pumps.
Please read this section carefully prior to installation.
Protective Clothing
ALWAYS wear protective clothing, face shield, safety glasses and gloves when working on or
near your metering pump. Additional precautions should be taken depending on the solution
being pumped. Refer to Safety Data Sheets (SDS) precautions from your solution supplier.
Water Pre-Prime
All LMI pumps are pre-primed with water when shipped from the factory. If your solution is not
compatible with water, disassemble the Pump Head Assembly. Thoroughly dry the pump head,
valves, O-rings, balls and diaphragm. Reassemble head assembly tightening screws in a
crisscross pattern. Refill the pump head with the solution to be pumped before priming the
pump. (This will aid in priming.)
Liquid Compatibility
CAUTION: The evaluation performed by ETL was tested with water only. The pumps are
certified to NSF 61 with: sodium hypochlorite (12.5%), sulfuric acid (98.5%), sodium hydroxide
(50%), and hydrochloric acid (30%). Determine if the materials of construction included in the
liquid handling portion of your pump are adequate for the solution (chemical) to be pumped.
Always refer to the solution supplier and the Milton Roy Chemical Resistance Chart for
compatibility of your specific Milton Roy metering pump. Contact your local Milton Roy distributor
for further information.
Tubing Connections
Inlet and outlet tubing or pipe sizes must not be reduced. Outlet tubing size must not be
increased. Make certain that all tubing is SECURELY ATTACHED to fittings prior to start-up (see
section 3.3 Tubing Connections). ALWAYS use LMI supplied tubing with your pump, as the
tubing is specifically designed for use with the pump fittings. It is recommended that all tubing be
shielded and secure to prevent possible injury in case of rupture or accidental damage. If tubing
is exposed to sunlight, black UV resistant tubing should be installed. Check tubing frequently for
cracks and replace as necessary.
Fittings and Machine Threads
All fittings should be hand-tightened. An additional 1/8 - 1/4 turn after the fitting is snug may be
necessary to provide a leak-proof seal. Excessive overtightening or use of a pipe wrench can
cause damage to the fittings, seals, or pump head.
Most LMI pumps have straight screw machine threads on the head and fittings and are sealed
by the O-rings. DO NOT use Teflon® tape or pipe dope to seal these threads. Teflon® Tape
may only be used on NPT threads.
Plumbing
Always adhere to your local plumbing codes and requirements. Be sure installation does not
constitute a cross connection. Check local plumbing codes for guidelines. LMI is not responsible
for improper installations.

PRECAUTIONS
2
Back Pressure/Anti-Syphon Valve
If you are pumping downhill or into low or no system pressure, a back pressure /anti-syphon
device should be installed to prevent over pumping or syphoning. Contact your LMI distributor
for further information.
Electrical Connections
WARNING: To reduce the risk of electrical shock, the metering pump must be plugged into a
properly grounded grounding-type receptacle with ratings conforming to the data on the pump
control panel. The pump must be connected to a good ground. Do not use adapters! All wiring
must conform to local electrical codes. If the supply cord is damaged, it must be replaced by the
manufacturer, stocking distributor, or authorized repair center in order to avoid a hazard.
Fuse (all models) and Battery
CAUTION: Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire.
The battery and fuse are internal, factory serviceable parts, and must be replaced by the factory
or a qualified distributor with parts of the same type and rating.
Flooding
WARNING: Install this pump in a location where flooding cannot occur.
Ground Fault Circuit Interrupter
WARNING: To reduce the risk of electric shock, install only on a circuit protected by a Ground
Fault Circuit Interrupter (GFCI).
Line Depressurization
To reduce the risk of chemical splash during disassembly or maintenance, all installations
should be equipped with line depressurization capability.
Over Pressure Protection
To ensure safe operation of the pump it is recommended that some type of safety / pressure-
relief valve be installed to protect the piping and other system components from failing due to
excessive pressure.
Chemical Concentration
There is a potential for elevated chemical concentration during periods of no flow, for example,
during backwash in the system. Steps, such as turning the pump off, should be taken during
operation or installation to prevent this.
See your distributor about other external control options to help mitigate this risk.
Retightening Components
Plastic materials will typically exhibit creep characteristics when under pressure over a period of
time and to insure a proper fit it may be necessary to retighten the head bolts periodically. To
insure proper operation, we recommend tightening the bolts to 25 inch-pounds after the first
week of operation and on a monthly basis thereafter.

PRECAUTIONS
3
Flow Display
The accuracy of the flow value as shown on the pump display is highly dependent on the
specific application. Calibration is necessary in order to display an accurate measure of the flow.
Spills
CAUTION: Spills of Dangerous chemicals should be cleaned up immediately.

OPERATION
4
2.0 Introduction
LMI's metering pumps deliver the highest level of repetitive accuracy and reliability
with the capability to pump a wide range of chemicals. Our comprehensive selection
of pumps means you get the right pump for the right application. Every one of our
pumps is engineered to exceed expectations and is backed by a global network of
highly trained field engineers and aftersales support.
This manual serves as a supplement to the Excel™XR Series Electronic Metering
Pump Installation & Operation Manual, part number 54630. It covers information
specific to the use, configuration and wiring of the additional modes of operation
available in the enhanced control model pumps.
Please review this manual carefully. Pay particular attention to warnings and
precautions. Always follow good safety procedures, including the use of
proper clothing, eye and face protection.
3.0 Icons
Table 1 explains the function of display screen icons not covered in the 54630 manual.
Table 1: Enhanced Pump Icons
Mode select
Manual mode
Analog mode
Batch mode
Pulse mode
Cycle timer mode
Timed event mode
Dosing is in progress

OPERATION
5
Analogue pacing signal (loss of signal alarm)
Analogue pacing signal (signal over range)
Pulse input not synched
Max pump volume exceeded (in pulse mode)
Max flow exceed in batch mode

OPERATION
6
4.0 Enhanced Control Operation
This manual covers features supported in the enhanced control model Excel™XR
Series pumps. Enhanced control features are driven by a variety of external inputs and
outputs. Please see section 5.0 Cable Wiring for information on connections, signal
types, and requirements.
4.1 Analog Mode
Analog mode allows control of the pump using an external 0 - 20 mA signal. The analog
mode home screen is shown in Figure 1.
Figure 1: Analog Mode Home Screen
To configure the analog mode input parameters, press the Up or Down buttons to
access the analog adjust screen (Figure 2).
Figure 2: Analog Adjust
Point 1
Point 2
Flow Rate
Input Current
Other manuals for Excel XR Series
3
Table of contents
Other LMI Water Pump manuals

LMI
LMI G Series User manual

LMI
LMI Milton Roy E7 Series User manual

LMI
LMI ROYTRONIC EXCEL AD2 User manual

LMI
LMI ROYTRONIC EXCEL AD9 series User manual

LMI
LMI Excel XR Series User manual

LMI
LMI KBL Series User manual

LMI
LMI Excel XR Series User manual

LMI
LMI Excel XR Series User manual

LMI
LMI PW5 User manual

LMI
LMI G Series User manual
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual