Leister Welding-Pen A User manual

The LEISTER Welding-Pen A and S are hot air tools that can be installed for continuous
operation. They have an ergonomic shape and are light weight what makes them
suita
ble as hand tools as well as for the installation into machines and vent constructions.
The cooled heater tube as well as the LEISTER screw-on drawing nozzle with
taking tip make the Welding Pen to a very efficient tool for plastic welding.
• Welding of thermoplastic materials and also single-ply flexible plastics in the
form of boards, tubes, profiles, foams, tiles and sheets.
•
The following procedures are possible:
Rod and melt welding by means of LEISTER nozzles
• The hot air tools Welding Pen A and S need an external air-supply
(LEISTER blower or compressed air).
LEISTER Welding-Pen A
LEISTER Welding-Pen S
Hot air tools
Please read operating instructions carefully
before use and keep for further reference.
GB
OPERATING INSTRUCTIONS
1
APPLICATION
®
LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland
Tel. +41 41 662 74 74 Fax +41 41 662 74 16
www.leister.com [email protected]
LEISTER Welding-Pen A
• Heating element protected
against overheating
• Adaptor tube with heat protection
• Temperature steplessly adjustable
by regulation of air flow
LEISTER Welding-Pen S
• Heating element protected
against overheating
•
Adaptor tube with heat protection
• Temperature steplessly adjustable
with potentiometer

Electrical safety: double insulated
2
TEST SIGNS
TECHNICAL DATA
Danger to life when opening the tool, as live components
and connections ar exposed. Unplug the tool before
opening it.
Incorrect use of hot air blowers can cause fire and
explosion hazard, especially near combustible materials
and explosive gases.
The tool must be operated with supervision. Warmth can
reach combustible materials, which are out of sight.
For personal protection on building sites we strongly
recommend the tool be connected to a GFCI (Ground
Fault Circuit Interrupter) or a RCCB (Residual Current
Cir
cuit Breaker) .
The voltage rating stated on the tool must correspond to
the line/mains voltage.
Do not touch the element housing and nozzle when they
are hot as they can cause burns. Let the tool cool down.
Do not point hot air flow in the direction of people or
animals.
Protect tool from damp and wet.
FI
120
230
WARNING
CAUTION
Welding-Pen A Welding-Pen S
Voltage V~ 120 230 100 120 230
Frequency Hz 50/60 50/60 50/60 50/60 50/60
Capacity W 600 1000 450 600 1000
Temperature °C 20 – 600 20 – 600 20 – 600 20 – 600 20 – 600
Air flow l/min. >70 >120 >40 >50 >60
Air pressure Pa max. 105 (dynamic)
Weight g 1000 with 3m cable, air hose and Y-connection
Size mm ø 32/43 × 270
Mains voltage cannot be switched over
This tool is CCA certificated (CENELEC Certification Agreement).

Description of tool
1. Heat protection tube
2. Potentiometer for temperature
adjustment
3. Handle
4. Hose clamp
5. Air hose
6. Y-connection
7. Hose connection for
air-supply G1/4”
8. Cable screw fitting for mains
supply M16 ×1.5
9. Power-supply cord
10. Cover
11. Screwed nozzle joint
1
234 5
1
11
11
54
68
9
7
10 34 5
3
USAGE Welding-Pen
Welding-Pen S
Welding-Pen A

Blower
• Use an air filter, if air is dusty.
• Air flow can be adjusted by the LEISTER air flow adjuster.
Compressed air
• When using compressed air, an oil and water filter must be connected.
• Air flow can be adjusted by air flow adjuster.
Operating conditions LEISTER Welding-Pen A
Fit appropriate nozzle as required.
Connect air supply with corresponding hose connection (7).
Adjust air flow by means of air flow adjuster or pressure reducing valve.
ATTENTION: Keep minimum required air flow according to data on page 2
Connect tool to the mains.
Set hot-air temperature by adjusting of air flow.
(Temperature must not exceed 600°C)
Heat up tool for about 5 minutes.
Let the tool cool down after use!
Operating conditions LEISTER Welding-Pen S
Fit appropriate nozzle as required.
Connect air supply with corresponding hose connection (7).
Adjust air flow by means of air flow adjuster or pressure reducing valve.
ATTENTION: Keep minimum required air flow according to data on page 2
Connect tool to the mains.
Adjust hot-air temperature by use of the potentiometer.
Heat up too for about 5 minutes.
Let the tool cool down after use!
Change of nozzle
• Let the tool cool down before changing the nozzle.
• Do not touch hot nozzle and only lay it on heat resistant surface because of fire
hazard.
• Nozzles can easily be screwed (M14) onto the heat protection tube.
• Use only LEISTER nozzles.
OPERATION
AIR SUPPLY
4
USAGE Welding-Pen
S
S
S
S
S
S
S
A
A
A
A
A
A
A

5
USAGE Welding-Pen
Function of heat protection Welding-Pen A
• Heating element switches off automatically if there is no or not sufficient air flow
(temperature >600°C)
Function of heat protection Welding-Pen S
• Heating element switches off automatically if there is no air flow.
• If there is not sufficient air flow, power will be electronically reduced and the
temperature keeps steady at about 600°C. If the air flow falls below a certain
value, the heating switches off automatically.
• Disconnect tool from the mains. There is an automatic reset of the circuit board
after 5 seconds.
• Check air flow
• Check hose connections
• Increase air flow
• Connect tool to the mains
• Only use LEISTER accessories
• LEISTER air flow adjuster
• PVC air hose
• Hose clamp for air hose
• Tubular nozzle ø 5 mm
• Draw nozzles with tacking tip for: rod ø 3 mm
rod ø 4 mm
profiled rod 90 – 5.7 mm
Accessories
Measurements when protection of heating element has been activated
ATTENTION! Do not operate tool without air supply!

6
BA Welding-Pen/ 11.2001_a/GB
LEISTER Process Technologies and their authorised Service Centres offer free
welding courses and training. (see page 1).
• Clean welding nozzles with a wire brush
• Check mains cable and plug
• Repairs have to be carried out by authorised LEISTER Service Centres only. They
guarantee a specialized and reliable repair service within 24 hours using original
LEISTER spare parts according to connection diagramms and spare parts lists.
• Guarantee and liability are in accordance with the guarantee certificate as well
as with the currently valid general business and sales conditions.
• LEISTER Process Technologies rejects any guarantee claims for tools which are not
in their original condition. The tools must never be altered or changed.
Technical data and specifications are subject to change without prior notice.
Your authorized Service Centre is:
GUARANTEE AND LIABILITY
SERVICE AND REPAIR
MAINTENANCE
TRAINING
®
LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland
Tel. +41 41 662 74 74 Fax +41 41 662 74 16
www.leister.com [email protected]

LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland
Tel. +41 41 662 74 74 Fax +41 41 662 74 16
www.leister.com [email protected]
®

LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland
Tel. +41 41 662 74 74 Fax +41 41 662 74 16
www.leister.com [email protected]
®
This manual suits for next models
1
Table of contents
Other Leister Welding Accessories manuals