Ledj LEDJ163 User manual

Order codes:
LEDJ163 - CW Black Housing
LEDJ163A - CW White Housing
LEDJ164 - WW Black Housing
LEDJ164A - WW White Housing
PF 35 Prole Spot
User Manual

www.prolight.co.uk PF 35 Prole Spot User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Oneyearfromdateofpurchase.

www.prolight.co.uk PF 35 Prole Spot User Manual
3
Product overview & technical specications
ThePF35Prolespotisaminiprolepoweredbyahighoutput35W
LEDandusesahighqualityopticalsystemforsharpandprecise
projection.Thebeamanglecanbemanuallyfocusedandalsoadjusted
viathe4framingshutters.Customgoboscanbettedintotheunitvia
theeasyaccessslot.Aglasstexturedgoboand4metaleffectgobos
arealsoincluded.Aremovableframeallowsuserstoeasilyinsert
colouredlters.0-100%outputanddimmercurvescanbeselectedvia
theon-board4buttonLEDmenuorDMX.
PF 35 Prole Spot
160mm 430mm
340mm
•1x35WcoolwhiteLED(7500K)/1x35WwarmwhiteLED(3200K)
•Adjustablebeamangle:15°-30°
•1kHzrefreshrate
•Adjustablefocus
•Highqualityopticalsystem
•DMXchannels:1/2or3selectable
•0-100%dimming
•4dimmingcurvesinbothLEDandhalogenproles:
Linear,squarelaw,inversesquarelawandS-curve
•4framingshutters
•Removablecolourframeforlters
•Easyaccessgoboslot
•Includesatexturedglassand4metalgobos
•Bracketallowsformultipleriggingoroorstandingapplications
•PowerCONinput/output
•3-PinXLRinput/output
•Fancooled
•SuppliedwithIRremote
Specications PF 35 Prole Spot
Powerconsumption 43W
Powersupply 100~240V,50/60Hz
Fuse T2A250V
Dimensions 340x160x430mm
Weight 3.2kg
Ordercode LEDJ163-CWVersion,BlackHousing
LEDJ163A-CWVersion,WhiteHousing
LEDJ164-WWVersion,BlackHousing
LEDJ164A-WWVersion,WhiteHousing
CWversion
0m 2m 3m 4m 5m
15° - Lux
30° - Lux
4000
1369
1m
16000
5480
1780
609
30°
1000
343
640
219
15°
WWversion
0m 2m 3m 4m 5m
15° - Lux
30° - Lux
3519
869
1m
14100
3480
1560
386
30°
880
217
563
139
15°

www.prolight.co.uk PF 35 Prole Spot User Manual
4
Technical specications
01-Earthpoint
02-LCDdisplay
03-Functionbuttons
04-IRremotesensor
05-Colourframereleasemechanism
06-Framingshutters
07-Goboslot
08-Zoomadjustment
09-Focusadjustment
10-3-PinDMXinput
11-3-PinDMXoutput
12-PowerCONinput
13-PowerCONoutput
14-Fuse:T2A250V
15-Hangingbracket
16-Hangingbracketadjustableknob
Inthebox:1 x xture,
4 x metal gobos,
1 x textured glass,
1 x IR remote,
1 x power cable
& 1 x user manual
MENU
ZOOM
FOCUS
UPENTER DOWN
PF 35 Prole Spot
www.prolight.co.uk
DMX INPUT DMX OUTPUT
FUSE: T2A 250V
POWER INPUT:
100-240V~50/60Hz
POWER OUTPUT:
100-240V~50/60Hz
02
04
03 12
01
10
16
06
09
07
08
05
11
06
13
14
15

www.prolight.co.uk PF 35 Prole Spot User Manual
5
Operating instructions
MENU
SLAVE MODE Slave mode
DMX MODE
ADDR:001
DMX
address
setting
DMX MODE
ADDR:001
DMX MODE
CHAN: 01
DMX MODE
DELAY:01
DMX MODE
ADDR:512
DMX MODE
CHAN: 02
DMX MODE
CHAN: 03
DMX MODE
DELAY:04
Fade in/out mode
FADE RUN
SPEED:09
FADE RUN
SPEED:01
FADE RUN
SPEED:16
Manual dimming mode
MANUAL
WHIE:255
MANUAL
WHIE:000
MANUAL
WHIE:255
MANUAL
STROB:00
MANUAL
STROB:15
OPTION:
BLGT: ON
Backlight setting
IR setting
Reset factory settings
OPTION
BLGT: ON
OPTION
BLGT:OFF
OPTION
IR : ON
OPTION
IR : OFF
OPTION
SYSRESET

www.prolight.co.uk PF 35 Prole Spot User Manual
6
DMX mode:
OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestexibilitywhenitcomes
tocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthe
xtureandeachxtureindependently.
ToaccesstheDMXaddressmode,pressthe“MENU”buttononthetopoftheunittoshow
“DMX MODE ADDR” ontheLCDdisplay.Nowusethe“UP”and“DOWN”buttonstosettherequired
DMXaddress.Pressthe“ENTER”buttontoshow“DMX MODE CHAN” ontheLCDdisplayandusethe
“UP”and“DOWN”buttonstoselecttherequiredtheDMXchannel(1/2or3selectable).Pressthe
“ENTER”buttontoconrmthesetting.Thedimmingcurvesettingswillnowbedisplayed,usethe“UP”
and“DOWN”buttonsontherearoftheunittoselectbetween“DMX MODE DELAY:01” ~
“DMX MODE DELAY:04”.Pressthe“ENTER” buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Master/slave mode:
Tosetthemasterunit,pressthe“MENU”buttononthetopofthemasterunittoselecteitherthemanu-
almodeofthefadein/outmode.
Tosettheotherunitsinslavemode,pressthe“MENU”buttononthetopoftheunittoshow“SLAVE
MODE”ontheLCDdisplay.Pressthe“ENTER”buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.
Operating instructions
Channel Value Function
1 000-255 Dimmer(0-100%)
2000-015 Nofunction
016-255 Strobe(slow-fast)
2 channel mode:
Channel Value Function
1 000-255 Dimmer(0-100%)
1 channel mode:
DELAY:01-Linear DELAY:02-SquareLaw DELAY:03-InverseSquareLaw DELAY:04-S-Curve
Channel Value Function
1 000-255 Dimmer(0-100%)
2000-031 LEDoff
032-063 LEDon
064-095 Strobe(slow-fast)
096-127 LEDon
128-159 Strobepulse(slow-fast)
160-191 LEDon
192-223 Stroberandom(slow-fast)
224-255 LEDon
3000-020 Linear(dimmingcurve)
021-040 SquareLaw(dimmingcurve)
041-060 InverseSquareLaw(dimmingcurve)
061-080 S-Curve(dimmingcurve)
081-255 Defaultdimmingcurve(setviamenu)
3 channel mode:

www.prolight.co.uk PF 35 Prole Spot User Manual
7
Operating instructions
Manual dimming mode:
Toaccessthemanualdimmingmodepressthe“MENU”buttonuntilthedisplayshows“MANUAL WHIE”
ontheLCDdisplay.Usethe“UP”and“DOWN”buttonstoselecttherequiredbrightnessfrom“000” ~
“255”.Pressthe“ENTER” buttonandthenusethe“UP”and“DOWN”buttonstoselecttheashspeed
fromfrom“00” ~“15”.Pressthe“ENTER” buttontoconrmthesetting.
Value: 000 - 255 (000 = low brightness, 255 = high brightness)
Value: 00 - 15 (00 = no ash, 15 = fast ash speed)
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Fade in/out mode:
Toaccessthefadein/outmode,press“MENU”untilthedisplayshows“FADE RUN”ontheLCD
display.Usethe“UP”and“DOWN”buttonstoselecttherequiredfadespeedfrom“01” ~“16”.
Pressthe“ENTER” buttontoconrmthesetting.
Value: 01 - 16 (01 = slow speed, 16 = fast speed)
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Backlight setting:
Toaccesstheunitsbacklightsetting,press“MENU”untilthedisplayshows“OPTION BLGT”ontheLCD
display.Usethe“UP”and“DOWN”buttonstoselectthebetween“ON” (backlighton)and“OFF”
(backlightgoesoffafter20seconds).Pressthe“ENTER” buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
IR setting:
ToaccesstheunitsIRsetting,press“MENU”untilthedisplayshows“OPTION BLGT”ontheLCDdisplay.
Pressthe“ENTER” buttontoshow“OPTION IR”ontheLCDdisplayandusethe“UP”and“DOWN”
buttonstoselectthebetween“ON” (IRreceiveron)and“OFF” (IRreceiveroff).
Pressthe“ENTER” buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Reset factory settings:
Toresettheunitbacktoitsfactorysettings,press“MENU”untilthedisplayshows“OPTION BLGT”on
theLCDdisplay.Pressthe“ENTER” buttontwicetoshow“SYSRESET”ontheLCDdisplay.Pressboththe
“UP”and“DOWN”buttonstogetherandtheunitwillresettofactorysettings.
Pressthe“ENTER” buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

www.prolight.co.uk PF 35 Prole Spot User Manual
8
Operating instructions
+–
0
SL S
F D
A
CW
21 3
54 6
87 9
DIMMING
FLASH DMX MODE
AUTO RUNBLACKOUT
SLAVE SET ADDR
01
04
08
05
09
07
02
08
03
06
IR remote functions:
01-Setstheunitintoblackoutoff/on(LEDon/off).
02-Runsthefadein/outmode,usethe‘+’and‘–’buttons
toadjusttheprogramspeed.
03-Runsthemanualdimmingmode.Pressthisbuttonfollowed
bythe‘+’and‘–’buttonstoadjustbrightness(000-255).
PresstheFlashbuttonfollowedbythe‘+’and‘–’buttons
toadjusttheashspeed.
04-Setstheashspeedinmanualdimmingmode.Pressthis
buttonfollowedbythe‘+’and‘–’buttonstoadjusttheash
speed.
05-Setstheunitinslavemode.
06-SetstheDMXaddress.Pressthisbuttonfollowedbythe
‘+’and‘–’/numberbuttonstoadjusttheDMXaddress.
07-SetstheDMXaddress,channelanddimmingcurve.
WheninDMXaddressmodepressthisbuttonfollowedbythe‘+’
and‘–’/numberbuttonstoadjusttheDMXaddress.
WheninDMXchannelmodepressthisbuttonfollowedbythe‘+’
and‘–’buttonstoselecttherequiredDMXchannelmode.
Whenindimmingcurvemodepressthisbuttonfollowedbythe
‘+’and‘–’buttonstoselectthedimmingcurverequired(see
page6fordimmingcurves).
08-Adjuststhefadein/outspeed,ashspeed,manualdimming
brightness,DMXaddress,DMXchannelanddimmercurves.
09-NumberbuttonstobeusedwhensettingtheDMXaddress.

www.prolight.co.uk PF 35 Prole Spot User Manual
9
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk PF 35 Prole Spot User Manual
10
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
This manual suits for next models
3
Table of contents
Other Ledj Dj Equipment manuals

Ledj
Ledj Spectra Flood Q40 User manual

Ledj
Ledj Colour Blast 80 User manual

Ledj
Ledj LEDJ187 User manual

Ledj
Ledj Display Floor User manual

Ledj
Ledj LEDJ58 User manual

Ledj
Ledj Rubix RGB 3D Panel User manual

Ledj
Ledj PRO LED Starcloths CW Series User manual

Ledj
Ledj LEDJ178 User manual

Ledj
Ledj STAR01 User manual

Ledj
Ledj Slimline 1T36 User manual

Ledj
Ledj LEDJ96 User manual

Ledj
Ledj LEDJ110 User manual

Ledj
Ledj Rapid QB1 User manual

Ledj
Ledj LEDJ195 User manual

Ledj
Ledj Event Spot DL MKII User manual

Ledj
Ledj Mood Bar User manual
Ledj
Ledj Pixel Storm 12 User manual

Ledj
Ledj LEDJ232 User manual

Ledj
Ledj LEDJ452 User manual

Ledj
Ledj Performer 200 Quad User manual