Lang 224ZS User manual

IL2810
ENVIROZONE SELECTRONIC
GAS GRIDDLE
Commercial
224ZS, 236ZS, 248ZS, 260ZS, 272ZS
224ZSD, 236ZSD, 248ZSD, 260ZSD, 272ZSD
Installation and
Operation
Instructions
2M-W2014 Rev. A 5/20/14
236ZS

SAFETY SYMBOL
Model No.:
Serial No.:
Voltage:
1-Phase or 3 Phase:
Purchased From:
Location:
Purchase Date:
Installed Date:
These symbols are intended to alert the user to the presence of important operating
and maintenance instructions in the manual accompanying the appliance.
FOR YOUR SAFTEY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST
EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/CGA-B149.1 NATURAL
GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE
APPLICABLE.
POST IN PROMINENT LOCATION
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS INFORMATION
SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER. AS A MINIMUM, TURN
OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT.
EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATION
& MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
EQUIPMENT.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE.
REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability.
Lang reserves the right to change speci cations and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the
specifications contained in this sheet are subject to change without notice. While Lang
Manufacturing exercises good faith efforts to provide information that is accurate, we are
not responsible for errors or omissions in information provided or conclusions reached as a
result of using the speci cations. By using the information provided, the user assumes all risks in con-
nection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial
number, voltage and purchase & Installation Information in the area below and have it ready when you
call to ensure a faster service.

1
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
TABLE OF CONTENTS
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 3
Equipment Description . . . . . . . . . . . . . . . . . . . . . . . . 4
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation
Ventilation & Clearence . . . . . . . . . . . . . . . . . . . . . . 5
Leg Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Electrical & Gas Connection. . . . . . . . . . . . . . . . . . . . 6
Initial Start-Up
Initial Lighting Procedure . . . . . . . . . . . . . . . . . . . . . 8
Seasoning Cooking Surface. . . . . . . . . . . . . . . . . . . . 8
Operation
Setting the Griddle Temperature . . . . . . . . . . . . . . . . . 9
Suggested Times and Temperatures . . . . . . . . . . . . . . . 9
Loading the Griddle . . . . . . . . . . . . . . . . . . . . . . . . 10
Sequence of Operation
Power On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Maintenance
Griddle Care (Chrome Surfaces) . . . . . . . . . . . . . . . . .11
Daily Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Weekly Cleaning . . . . . . . . . . . . . . . . . . . . . . . . .12
Burner Air Shutter Adjustment. . . . . . . . . . . . . . . . . . . 12
Troubleshooting
Symptoms / Possible Causes . . . . . . . . . . . . . . . . . . . 13
Possible Causes / Test . . . . . . . . . . . . . . . . . . . . . .14
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Exploded View & Parts List . . . . . . . . . . . . . . . . . . . . . 16-27
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at (314) 678-6315
NOTICE ServiceonthisoranyotherLangappliancemustbeperformedbyqualied
personnel only. Consult your Lang Authorized Service Agent Directory.
You can call our tech service number (314) 678-6315 or visit our website
WWW.LANGWORLD.COM for the service agent nearest you.

2
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
16.5”
20.5”
31.4”
TOP
FRONT SIDE
W
4”
IL2811
EQUIPMENT SPECIFICATIONS
Model Height x Width x Depth*
(Not including legs)
Clearance from
combustible surface
Weight Freight
Class
Actual Shipping
224ZS 16.4” x 24.1” x 30.4”
Sides: 5”, Back: 5”
243 lbs. 280 lbs.
65
418mm x 613mm x 773mm 110 kg 127 kg
236ZS 16.4” x 36.1” x 30.4” 368 lbs. 420 lbs.
418mm x 917mm x 773mm 167 kg 191 kg
248ZS 16.4” x 48.1” x 30.4” 448 lbs. 520 lbs.
418mm x 1222mm x 773mm 204 kg 236 kg
260ZS 16.4” x 60.1” x 30.4” 556 lbs. 635 lbs.
418mm x 1527mm x 773mm 253 kg 289 kg
272ZS 16.4” x 72.1” x 30.4” 689 lbs. 800 lbs.
418mm x 1832mm x 773mm 313 kg 364 kg
*= For units with a 30” Deep Griddle surface, add 7” to the overall depth of the unit.

3
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
SPECIFICATIONS
EQUIPMENT SPECIFICATIONS continued
Model NAT.
Gas
LP
Gas
Burner
Input Manifold Gas Connection (3/4” NPT)
Electrical Requirments
Voltage Total
kW Phase Amps /
Line
224ZS-NAT X
27000
BTU/hr
5 WC
1
54,000 BTU/hr
115V/60Hz 0.5 1 2.0
224ZS-LP X10 WC
236ZS-NAT X5 WC 81,000 BTU/hr
236ZS-LP X10 WC
248ZS-NAT X5 WC 108,000 BTU/hr
248ZS-LP X10 WC
260ZS-NAT X5 WC 135,000 BTU/hr
260ZS-LP X10 WC
272ZS-NAT X5 WC 162,000 BTU/hr
272ZS-LP X10 WC
Model NAT.
Gas
LP
Gas
Burner
Input Manifold Gas Connection (3/4” NPT)
Electrical Requirments
Voltage Total
kW Phase Amps /
Line
224ZSD-NAT X
35000
BTU/hr
5 WC
1
70.000 BTU/hr
115V/60Hz 0.5 1 2.0
224ZSD-LP X10 WC
236ZSD-NAT X5 WC 105,000 BTU/hr
236ZSD-LP X10 WC
248ZSD-NAT X5 WC 140,000 BTU/hr
248ZSD-LP X10 WC
260ZSD-NAT X5 WC 175,000 BTU/hr
260ZSD-LP X10 WC
272ZSD-NAT X5 WC 210,000 BTU/hr
272ZSD-LP X10 WC

4
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
EQUIPMENT DESCRIPTION
Exterior Construction
The griddle dimensions are 17” (43.18cm) High, 30” (76.20cm) Deep, and width is dependent on the
actual model number.
The Sides, Bottom, and Rear wall are constructed of double wall stainless steel, which allows closer
installation to combustible surfaces.
The stainless steel drop-down door keeps the controls cool and control area clean.
The griddle surface is made of 1” thick, highly polished steel to reduce hot and cold spots, recovery
problems, warping, and ensure even heat to the edges of the griddle.
Controls
The Selectronic Griddle comes with the solid state controls which include:
• A Main Power Switch & Power Indicator for the entire unit.
• Each twelve-inch section has its own temperature selector switch that snaps into place to lock in
any temperature from 175°F to 450°F (79°C to 232°C) in 25° increments.
• Each twelve-inch section of the griddle is controlled by an area sensitive RTD probe, which can
sense and react to a temperature change of +/- 4°F.
Technical
• Griddle operates on either Natural gas or Propane. This must be specied when ordering. It is
shipped with a Power Cord and Plug attached.
• Floor space required is 30” (76.20cm) Deep, and width is 2 ft, 3ft, 4ft, 5ft, or 6ft depending on actual
model number.
• The griddle weighs 260, 390, 520, 650, 780 lbs. depending on actual model number.
GriddleGasandVoltageSpecications
The Lang Model can be connected to any 120 Volt source. The gas and electrical specications are
listed in the table on the previous page.
NOTICE The data plate is on the right side of the griddle. The oven voltage,
wattage,serialnumber,wiresize,andclearancespecicationsare
on the data plate. This information should be carefully read and
understood before proceeding with the installation.
Main
Power
Switch
Grease
Drawer
Legs
Gutter
Section
Temp. Dial
Section
Power
Switch
1” Griddle Surface

5
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
UNPACKING
Receiving the Griddle
Upon receipt, check for freight damage, both visible and concealed.
Visible damage should be noted on the freight bill at the time of delivery and
signed by the carrier’s agent. Concealed loss or damage means it does not
become apparent until the merchandise has been unpacked. If concealed
loss or damage is discovered upon unpacking, make a written request for
inspection by the carrier’s agent within 15 days of delivery. All packing
material should be kept for inspection. Do not return damaged
merchandise to Star Manufacturing Company. File your claim with the
carrier.
Location
Prior to un-crating, move the oven as near to its intended location as practical. The crating will help
protect the unit from the physical damage normally associated with moving it through hallways and
doorways.
Un-crating
The griddle will arrive completely assembled inside a wood frame and strapped to a skid.
Cut the straps and remove the wood frame.
The oven can now be removed from the skid.
THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER
SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS
HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK)
TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF
INSTALLATION.
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH OVEN WILL BE
LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE GRIDDLE.
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
VENTILATION & CLEARENCE
CLEARANCE
For use on non-combustible countertops only.
Combustible and non-combustible material must be at least 48” (120cm) from the top of the
appliance and 5” (150mm) from the sides and back. Adequate clearance should also be provided
for proper operation and servicing.
AIR SUPPLY
Make certain not to obstruct the ow of combustion and ventilation air. Provisions for adequate air
supply must be furnished. The legs supplied with the unit must be installed. Make certain that air
intake openings in the bottom of the appliance are not obstructed. They are essential for proper
combustion and operation of the appliance.
EXHAUST CANOPY
It is essential that facilities be provided over the griddle to carry off fumes and gases. However,
the unit should not be directly connected to a ue or stack.
CAUTION

6
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
INSTALLATION
Leg Installation
There are four, adjustable legs provided for
Enviro-Zone griddles.
The legs are shipped in the grease drawer(s)
of the griddle. Install them into the threaded
holes on the underside of the griddle body.
Leveling adjustment may be done by screwing
the bottom portion of the leg in and out.
Electrical Connection
The griddle is supplied with a cord and plug.
The receptacle is not provided with the griddle.
Follow the receptacle manufacturer’s
instructions when connecting the receptacle to
the power supply.
Gas Connection
This griddle is manufactured for use with the
type of gas indicted on the nameplate.
Contact the factory if your type of gas does not
match the nameplate data.
All gas connectors must be in accordance with local codes and comply with the National Fuel Federal
Gas Codes ANSI Z223.1 latest edition.
This appliance should be installed with a separate gas valve in the gas line ahead of the unit. Use a
3/4 inch or larger gas supply line.
Remove the 5/16 inch nuts securing the rear of burners. These nuts are for securing the main
burners during transportation only. The rear burner shield must be removed to gain access to the
nuts.
A pressure regulator for the type of gas specied is supplied with each appliance.
This regulator must be installed in the gas supply line. (Note the direction of the gas ow arrow.)
The pressure in the manifold of the appliance should be tested with a manometer and the regulator
adjusted for proper pressure with the appliance operating at full re. A 1/8 inch NPT tap is provided in
the manifold for connecting a manometer.
Correct manifold pressures are:
5 inches water column for natural gas
10 inches water column for propane
When replacing the plug in the manifold, a pipe joint compound or sealant should be used that is
resistant to the action of liquid petroleum gas.
Initial adjustments are the responsibility of the installer and are not chargeable to Lang Manufacturing.
After the griddle is in its nal position, adjust the legs to create 1/8 inch slant from back to front.
This will allow the grease to run into the grease gutter and provide the proper combustion air for the
burners.
IL2804
Above: typical leg installation

7
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
INSTALLATION continued
DANGER: THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION
AND DEATH.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO
WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN
CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT
MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE: The data plate is located inside the control compartment of each griddle.
Thegriddlevoltage,serialnumber,gasspecications,andclearance
specicationsareonthedataplate.Thisinformationshouldbecarefullyread
and understood before proceeding with the installation.
NOTICE: The installation of any components such as a vent hood, grease extractors,
reextinguishersystems,mustconformtotheirapplicableNational,Stateand
locally recognized installation standards.
WARNING

8
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
INITIAL START UP
Initial Lighting Procedure
Clean the preservative coating from the griddle plate and splash guard. Add a mild detergent to hot
water and wash the griddle plate and splash guard. Rinse with a damp sponge and dry with a clean
rag.
WARNING: BEFORE LIGHTING, USE A SOAP AND WATER SOLUTION TO
TEST ALL JOINTS FOR GAS LEAKS.
• Plug the unit into a 115-volt power supply.
• Turn the ON-STANDBY toggle switch to ON.
• Set the temperature dials to the desired temperature.
• Turn the toggle switch to each section to ON.
• To turn the griddle off, simply turn the main toggle switch to STANDBY.
Seasoning the Griddle Plate (non chrome only)
• Set the temperature dials to 300°F (148°C).
• Observe the burners through the opening at the top of the control panel.
• When the burners go OFF, apply a thin coat of high-grade, non-salted vegetable oil to the
griddle surface.
• Rub the oil into the griddle surface with the at side of a spatula or a towel.
• Recoat any dry spots that appear then wait two minutes and wipe off any excess oil.
• Repeat the seasoning process at 350°F (176°C) and at 400°F (204°C).
NOTICE: Duringtherstfewhoursofoperationyoumaynoticeasmall
amount of smoke coming off the griddle, and a faint odor from
the smoke. This is normal for a new griddle and will disappear
aftertherstfewhoursofuse.
This manual suits for next models
9
Table of contents
Other Lang Griddle manuals

Lang
Lang SELECTRONIC Manual

Lang
Lang 148TT Operating instructions

Lang
Lang ACCU-TEMP Service manual

Lang
Lang Cruise CLG-48C-S Operating instructions

Lang
Lang CLG-36-U Operating instructions

Lang
Lang AGC User manual

Lang
Lang 172TBC User manual

Lang
Lang 424T User manual

Lang
Lang 124S User manual

Lang
Lang 236ZC Chrome Manual
Popular Griddle manuals by other brands

Keating Of Chicago
Keating Of Chicago MIRACLEAN PRE-2000 manual

Nexgrill
Nexgrill 720-0786A owner's guide

Outwell
Outwell FH-3047C instruction manual

Rankam
Rankam Member's Mark GR2298901-MM-02 Assembly & operating instructions

Black Stone
Black Stone 1972 owner's manual

Star
Star Ultra Max 760TA Installation and operation instructions