Lacanche LAG 010 CKG User manual

LAG 010 CKG
GAS LAVA ROCK
CHARGRILL
HOB TOP OPTION
INTEGRATED HOB ELEMENT
LAG 010 CKG - Ft 126a - GB - Rév 02 - Modifié le : 08/10/2013 1/17

TECHNICAL DATA SHEETS, MEASUREMENTS AND DIMENSIONS
———————————————————————————————————————————3
INSTALLER’S MANUAL 5
SITTING
——————————————————————————————————————————7
GAS CONNECTION
——————————————————————————————————————————8
CHANGE OF GAS
——————————————————————————————————————————9
ELECTRIC CONNECTION
—————————————————————————————————————————11
REPARATIES
——————————————————————————————————————————11
GAS LINE
——————————————————————————————————————————12
USER’S MANUAL 13
USE LAVA ROCK GRILL
——————————————————————————————————————————15
CLEANING AND MAINTENANCE
—————————————————————————————————————————17
CONTENTS
GAS LAVA ROCK CHARGRILL
LAG 010 CKG - Ft 126a - GB - Rév 02 - Modifié le : 08/10/2013 2/17

INSTALLER’S MANUAL
► A 4-kW gas burner, controlled by a thermocouple safety valve.
► A 260 x 460 mm grill resting on pillars is located above the re tray.
► Electric push button ignition.
Charcoal : Hop top, gas lava rock chargrill left or right of central hob (depending on model)
Pressures and hourly consumption :
The gas lava rock chargrill can oprate from a supply of either mains gas or LPG but it must be congured
for either, please refer to power plate and marking at the rear of the range (CKG : table.3, appendix 0).
Accessories :
► Cooking grill.
► Grease trap.
►Ash-drawer.
Directives :
Gas appliances : 2009/142/CEE.
Low Voltage : 2006/95/CEE.
CEM : 2004/108/CEE.
TECHNICAL DATA
LAG 010 CKG - Ft 126a - GB - Rév 02 - Modifié le : 08/10/2013 3/17


HOB TOP OPTION
GAS LAVAROCK CHARGRILL
LAG 010 CKG
INSTALLER’S MANUAL
Appliances must be installed in a workmanlike manner in accordance with the instructions in this manual
and locally applicable regulations.
This manual should be handed over to the user after installation.
LAG 010 CKG - Ft 126a - GB - Rév 02 - Modifié le : 08/10/2013 5/17


INSTALLER’S MANUAL
INSTALLATION / POSITIONING
A shut-off valve must be install and accessible close to the appliance in order to isolate it from the gas
applicable or to facilitate cutting the gas supply : Please ensure that installation complies with local
applicable regulations and standards
- Natural gas supply :
Mandatory to install an Automatic Shut-off Valve (since 1st July 1997 in France)
- LPG supply (butane, propane) :
Propane : Class 1 Safety Expansion Valve.
Butane : Butane safety expansion valve tted to the cylinder (connected to the range by a LPG approved
hose, maximum length 2 metres).
LAG 010 CKG - Ft 126a - GB - Rév 02 - Modifié le : 08/10/2013 7/17

INSTALLER’S MANUAL
Recommendations :
Ensure that the oven is set to the type of gas used (see label on the gas connector).
If the gas supply is not compatible with the gas setting of your range the setting must be modied. Refer
to the “Changing gas type” section of the present instructions.
Butane-fuelled units : Connect unit to 2.6 kg/h pressure reducer. Use two cylinders connected to a 3-way
valve ahead of the pressure regulator in case of prolonged, continuous duty.
Propane-fuelled units : Connect unit to a 3.0 kg/h pressure reducer. Use two cylinders and a 3-way
valve ahead of the pressure regulator in case of prolonged, continuous duty. The use of 37 kg or external
cryogenic tanks is both possible and recommended.
Before connection :
Check :
◊ That the gas supply pressure matches the gas pressure for which the range is set.
◊ Pipework is perfectly clean in order to prevent the injectors becoming blocked and malfunctioning of
the magnetic heads.
◊ The gas for which the appliance was set up : rating plate and markings.
◊ Cross-sectional area of gas supply pipework is compatible with the appliance’s thermal output.
◊ Correct fresh air flowrate (air supply sufcient to enable correct combustion to occur (see appendix 1).
Gas connection :
Male coupling Ø 15/21, 1/2” gas thread on (see A, figure 1).
After connection :
Check the mains pressure at (see B, figure 2).
Check your connection is gastight.
B
A
12
GAS CONNECTION
LAG 010 CKG - Ft 126a - GB - Rév 02 - Modifié le : 08/10/2013 8/17

INSTALLER’S MANUAL
Changing Jet :
Remove the jet (see A, figure 1) and replace with the appropriate sized jet (see table 6, appendix 0
(Ø in 1/100 mm).
Adjusting the primary air :
Loosen the screw that secures the air ring B/ figure 2.
Adjust the airflow by moving the adjusting air ring (Charcoal : tabel 7 in appendix 0).
Commissioning (ne tuning) gas burners :
After connection or changing gas type, it is imperative to adjust for a ne tuning :
► Ignite the burner in MAX. Wait for 10 minutes to reach temperature and then reduce to minimum setting,
and remove the control knob.
► Using a flathead screwdriver adjust the simmer flame accordingly (see C, figure 3).
Note : Flame is reduced to ¼ of you turn maximum to minimum. Looking for a crisp ame without any
yellow wich does not go out when turned from maximum to minimum.
CHANGING GAS TYPE
(LAVAROCK LAG 010 CKG)
Lacanche ranges are supplied with the appropriate gas tting for the gas type specied when the order is
placed. However, the settings must be ne (COMMISIONED) when the cooker is installed.
The cooker is designed to operate with the gases in table 4, appendix 0.
CAUTION : Close the mains gas valve before carrying out any works.
IMPORTANT
In case of use with a gas other than that for which the cooker was initially set up, it is crucial to
replace the injectors and modify the adjustments as dened below.
1
2
3
A
B
C
Adjusting air ring
LAG 010 CKG - Ft 126a - GB - Rév 02 - Modifié le : 08/10/2013 9/17

INSTALLER’S MANUAL
Setting the safety thermocouple :
If the burner goes out, having kept the control knob pushed in for approximately twenty seconds, check
that :
- The magnetic head grips the valve moderately, nger right.
- The tipt of thermocouple (see D, figure 4) should be touched by the flame without coming into
contact with the burner.
- The thermocouples and magnetic heads are absolutely clean.
Looking for crisp blue flame without any yellow wich does not out when turned from maximum to minimum.
D
4
CHANGE OF GAS
LAG 010 CKG - Ft 126a - GB - Rév 02 - Modifié le : 08/10/2013 10/17
Other manuals for LAG 010 CKG
2
Table of contents
Other Lacanche Grill manuals
Popular Grill manuals by other brands

Kenmore
Kenmore 415.16123800 Use and care guide

Camp Chef
Camp Chef PG24CLAU Warning & instruction booklet

Tucker Barbecues
Tucker Barbecues GTR Series Assembly, installation and operating instructions

Monogram
Monogram ZGG540NCP1SS owner's manual

Equipex
Equipex Sodir Savoy Operation manual

Gaggenau
Gaggenau VR 414 610 use and care manual