Notice for Safety Operation
The product performs reliably as long as it is used according to the guidance. Artificial
damage or destruction of the device should be avoided. Before using the device, read this
notice carefully for personal and equipment safety. Please keep the manual for further
reference. Kyland is not liable to any personal or equipment damage caused by violation of
this notice.
Do not place the device near water sources or damp areas. Keep the ambient relative
humidity within the range from 5% to 95% (non-condensing).
Do not place the device in an environment with high magnetic field, strong shock, or high
temperature. Keep the working and storage temperatures within the allowed range.
Install and place the device securely and firmly.
Please keep the device clean; if necessary, wipe it with a soft cotton cloth.
Do not place any irrelevant materials on the device or cables. Ensure adequate heat
dissipation and tidy cable layout without knots.
Wear antistatic gloves or take other protective measures when operating the device.
Avoid any exposed metal wires because they may be oxidized or electrified.
Install the device in accordance with related national and local regulations.
Before power-on, make sure the power supply is within the allowed range of the device.
High voltage may damage the device.
Power connectors and other connectors should be firmly interconnected.
Do not plug in or out the power supply with wet hands. When the device is powered on,
do not touch the device or any parts with wet hands.
Before operating a device connected to a power cable, remove all jewelry (such as rings,
bracelets, watches, and necklaces) or any other metal objects, because they may cause
electric shock or burns.
Do not operate the device or connect or disconnect cables during an electrical storm.
Use compatible connectors and cables. If you are not sure, contact our sales or
technical support personnel for confirmation.

Do not disassemble the device by yourself. When an anomaly occurs, contact our sales
or technical support personnel.
If any part is lost, contact our sales or technical support personnel to purchase the
substitute. Do not purchase parts from other channels.
Dispose of the device in accordance with relevant national provisions, preventing
environmental pollution.
In the following cases, please immediately shut down your power supply and contact your
Kyland representative:
Water gets into the equipment.
Equipment damage or shell damage.
Equipment operation or performance has abnormally changed.
The equipment emits odor, smoke or abnormal noise.

I
CONTENTS
1 Product Overview .......................................................................................................... 1
2 Structure and Interface .................................................................................................. 2
2.1 Front Panel ................................................................................................................ 2
2.2 Top Panel ................................................................................................................... 3
3 Mounting ........................................................................................................................ 4
3.1 Dimension Drawing .................................................................................................... 4
3.2 Mounting Modes and Steps ....................................................................................... 4
3.2.1 Mounting ............................................................................................................. 5
3.2.2 Wall Mounting ..................................................................................................... 5
4 Connection .................................................................................................................... 7
4.1 10/100/1000Base-T(X) Ethernet Port ......................................................................... 7
4.2 100/1000Base-X, 10/100/1000Base-T(X) SFP slot .................................................... 8
4.2.1 Gigabit SFP Optical Module ................................................................................ 9
4.2.2 Gigabit SFP Electrical Module .......................................................................... 10
4.3 Console Port ............................................................................................................ 10
4.4 Grounding / Power Terminal Block/ Alarm Terminal Block........................................ 12
4.5 SYSTEM RESET ...................................................................................................... 13
5 LEDs ............................................................................................................................ 14
6 Switch Access ............................................................................................................. 15
6.1 Access through Console Port................................................................................... 15
6.2 Access through Telnet .............................................................................................. 17
6.3 Access through Web ................................................................................................ 18
7 Basic Features and Specifications............................................................................... 19

Product Overview
1
1 Product Overview
Managed video surveillance SICOM3014GV Industrial Ethernet Switch applied in the ITS,
highway, industrial automation, oil&gas and many other industries. The SICOM3014GV are
applicable to harsh and hazardous industrial environments due to its high-performance
switching engine, solid closed housing, fanless but heat dissipation-capable single-rib
shaped chassis, overcurrent, overvoltage, and EMC protection for power input, and EMC
protection of RJ45 ports. The redundant network and power input support guarantees the
reliable operation of the system.
The SICOM3014GV provide powerful network management functions. The device can be
managed through CLI, Telnet, Web.
The device support DIN rail and panel mounting. For details, see the following table.
Table 1 SICOM3014GV Models
Model SICOM3014GV- Ports - PS1- PS2
Code definition Code option
Ports: GX/GE
4GX10GE
Note
:
4GX10GE
:
four 100/1000Base-X
,
10/100/1000Base-T(X) SFP slots
;
ten 10/100/1000Base-T(X) ports.
PS1:power input 1 L15(12-58VDC)
PS2: power input 2 L15(12-58VDC)
Note:
We reserve the right to amend the product information listed in this table without notice. To
obtain the latest information, contact our sales or technical support personnel.

Structure and Interface
2
2 Structure and Interface
Caution:
It is recommended to purchase the port dustproof shield (optional) to keep ports clean
and ensure switch performance.
2.1 Front Panel
Figure 1 Front Panel
Table 2 Description of the Front Panel
No. Identifier Description
(1) 11-14 four 100/1000Base-X,10/100/1000Base-T(X) SFP slots
(2) 1-10 ten 10/100/1000Base-T(X) ports
(3) PWR1 power 1 LED
(4) PWR2 power 2 LED
(5) Alarm Alarm LED

Structure and Interface
3
2.2 Top Panel
Figure 2 Top Panel
Table 3 Description of the Top Panel
No. Identifier Description
(1) PWR1 Power terminal block 1
(2) Console Console port
(3) Reset Reset button for switch
(4) ALM Alarm relay output
(5) Grouding screw
(6) PWR2 Power terminal block 2

Mounting
4
3 Mounting
3.1 Dimension Drawing
Figure 3 Dimensions (unit: mm)
Caution:
As part of the heat dissipation system, the switch housing becomes hot during operation.
Please use caution when coming in contact and avoid covering the switch housing when the
switch is running.
The figures in this manual are only for reference.
3.2 Mounting Modes and Steps
The switch support DIN-rail and panel mounting. Before installation, make sure that the
following requirements are met.
1) Environment: temperature (-40℃ to 75℃), ambient relative humidity (5% to 95%,

Mounting
5
non-condensing)
2) Power requirement: The power input is within the voltage range of the switch.
3) Grounding resistance: <5
4) No direct sunlight, distant from heat source and areas with strong electromagnetic
interference.
3.2.1 Mounting
DIN-Rail Mounting
Step 1: Select the mounting position for the device and guarantee adequate space and heat
dissipation .
Step 2: Insert the connecting seat onto the top of the DIN rail, and push the bottom of the
device inward and upward to ensure the DIN rail fits in the connecting seat. Make
sure the device is firmly installed on the DIN rail, as shown in the following figure.
Figure 4 DIN-Rail Mounting
3.2.2 Wall Mounting
Note:
Purchase the plate (optional) for panel mounting.
Wall Mounting
Screw the wall-mount brackets with screws in the accessory kit.
Table of contents
Other KYLAND Switch manuals

KYLAND
KYLAND SICOM3000A-LITE Assembly instructions

KYLAND
KYLAND Aquam8012A-1U Series Assembly instructions

KYLAND
KYLAND SICOM3024P Assembly instructions

KYLAND
KYLAND KIEN6000T User manual

KYLAND
KYLAND SICOM3000S Assembly instructions

KYLAND
KYLAND Aquam5 Series Assembly instructions

KYLAND
KYLAND Aquam8112 Series Assembly instructions

KYLAND
KYLAND Opal5G Series Assembly instructions

KYLAND
KYLAND KIEN1008BA Series Assembly instructions

KYLAND
KYLAND Aquam5S Series User manual