Kubler 573T User manual

Operating Manual
R60726.0002 - Index 4
German is the original version.
Multifunctional Display 573T *)
Process indicator with two 16 bit analog inputs, touch screen and graphic display
Product Features:
•Operating modes for visualization of input 1, input 2 or combinations of inputs (IN1+IN2, IN2-IN2, IN1xIN2, IN1:IN2)
•Two universal 16 bit analog inputs for -10 … +10 V / 0 … 10 V / 0 … 20 mA / 4 … 20 mA
•High accuracy reference output 10 V for potentiometers > 1 kOhm
•Bright and high-contrast display with event-dependent color variations
•Emulation of a 7-segment display inclusively icons and units
•Intuitive and easy parameterization by plain text and touchscreen
•24 V auxiliary output for encoder supply
•Totalization for each input
•Linearization with 24 control points for each input
•Numerous features, e. g. tara, averaging filter, sampling time for each input
•96 x 48 mm (3.78 x 1.89 inch) norm panel housing and IP65 protection
*) IO-Link in preparation / available on request

R60726.0002 – Index 4 EN - page 2
Version
Description
573T_01a /Jan-17
First Version
573T_02a /Feb-17
Second Version
573T_02b /March-17
minor changes and fixes
573T_3a /Oct-17
Index 3, expansion of the scale units
573T_4a /April-18
Extension with IO-Link
in preparation / available on request
573T_5a /June-18
Extension with Modbus
Legal notices:
All contents included in this manual are protected by the terms of use and copyrights of Fritz Kübler GmbH.
Any reproduction, modification, usage or publication in other electronic and printed media as well as in the
internet requires prior written authorization by Fritz Kübler GmbH.
German is the original version.

R60726.0002 – Index 4 EN - page 3
Table of Contents
1.
Safety Instructions and Responsibility..................................................................... 5
1.1 General Safety Instructions................................................................................................ 5
1.2 Use according to the intended purpose .............................................................................. 5
1.3 Installation........................................................................................................................ 6
1.4 Cleaning, Maintenance and Service Notes.......................................................................... 6
2.
Introduction .......................................................................................................... 7
2.1 Operation mode ................................................................................................................ 7
2.2 Function diagram .............................................................................................................. 8
3.
Electrical Connections ........................................................................................... 9
3.1 DC Power Supply ............................................................................................................... 9
3.2 Auxiliary Voltage Output..................................................................................................... 9
3.3 Analog Input.................................................................................................................... 10
3.4 Reference Output ............................................................................................................ 10
3.5 Control Inputs ................................................................................................................. 11
3.6 Analog Output (Option) .................................................................................................... 11
3.7 Serial interface (Option RS232 or RS485)........................................................................ 12
3.8 Control-Output (Option) ................................................................................................... 13
3.9 AC Power supply (Option)................................................................................................. 13
3.10 Relay Output (Option) ...................................................................................................... 14
3.11 IO-Link (Option)............................................................................................................... 15
4.
Display and touch screen ..................................................................................... 16
4.1 Screen structure for parametrization ................................................................................ 16
4.2 Screen structure in operation ........................................................................................... 17
5.
Parameter / Overview-Menu Structure .................................................................. 18
5.1 General Menu.................................................................................................................. 20
5.2 IN 1 Properties ................................................................................................................ 21
5.3 IN 1 Linearization ............................................................................................................ 23
5.4 IN 1 Totalization .............................................................................................................. 24
5.5 IN 2 Properties ................................................................................................................ 25
5.6 IN 2 Linearization ............................................................................................................ 26
5.7 IN 2 Totalization .............................................................................................................. 26
5.8 Linkage Properties........................................................................................................... 27
5.9 IO-Link Properties............................................................................................................ 28
5.10 Preselection Values ......................................................................................................... 29
5.11 Preselection 1 Menu........................................................................................................ 30
5.12 Preselection 2 Menu........................................................................................................ 34
5.13 Preselection 3 Menu........................................................................................................ 35
5.14 Preselection 4 Menu........................................................................................................ 36
5.15 Serial Menu..................................................................................................................... 37
5.16 Analog Out Menu............................................................................................................. 39
5.17 Command Menu.............................................................................................................. 41
5.18 Display Menu .................................................................................................................. 43
6.
Appendix ............................................................................................................ 46
6.1 Data readout via serial interface ...................................................................................... 46
6.2 Appendix: Display of scale units....................................................................................... 47
6.4 Linearization ................................................................................................................... 56
6.5 Dimensions ..................................................................................................................... 58

R60726.0002 – Index 4 EN - page 4
6.6 Technical specifications................................................................................................... 59

R60726.0002 – Index 4 EN - page 5
1.
Safety Instructions and Responsibility
1.1 General Safety Instructions
This operation manual is a significant component of the unit and includes important rules and hints
about the installation, function and usage. Non-observance can result in damage and/or impairment of
the functions to the unit or the machine or even in injury to persons using the equipment!
Please read the following instructions carefully before operating the device and observe all safety and
warning instructions! Keep the manual for later use.
A pertinent qualification of the respective staff is a fundamental requirement in order to use these
manual. The unit must be installed, connected and put into operation by a qualified electrician.
Liability exclusion:
The manufacturer is not liable for personal injury and/or damage to property and for
consequential damage, due to incorrect handling, installation and operation. Further claims, due to
errors in the operation manual as well as misinterpretations are excluded from liability.
In addition the manufacturer reserves the right to modify the hardware, software or operation manual at
any time and without prior notice. Therefore, there might be minor differences between the unit and the
descriptions in operation manual.
The raiser respectively positioner is exclusively responsible for the safety of the system and equipment
where the unit will be integrated.
During installation or maintenance all general and also all country- and application-specific safety
rules and standards must be observed.
If the device is used in processes, where a failure or faulty operation could damage the system or injure
persons, appropriate precautions to avoid such consequences must be taken.
1.2 Use according to the intended purpose
The unit is intended exclusively for use in industrial machines, constructions and systems. Non-
conforming usage does not correspond to the provisions and lies within the sole responsibility of the
user. The manufacturer is not liable for damages which have arisen through unsuitable and improper
use.
Please note that device may only be installed in proper form and used in a technically perfect condition
(in accordance to the Technical Specifications). The device is not suitable for operation in explosion-
proof areas or areas which are excluded by the EN 61010-1 standard.

R60726.0002 – Index 4 EN - page 6
1.3 Installation
The device is only allowed to be installed and operated within the permissible temperature range.
Please ensure an adequate ventilation and avoid all direct contact between the device and hot or
aggressive gases and liquids.
Before installation or maintenance, the unit must be disconnected from all voltage-sources. Further it
must be ensured that no danger can arise by touching the disconnected voltage-sources.
Devices which are supplied by AC-voltages must be connected exclusively by switches, respectively
circuit-breakers with the low voltage network. The switch or circuit-breaker must be placed as near as
possible to the device and further indicated as separator.
Incoming as well as outgoing wires and wires for extra low voltages (ELV) must be separated from
dangerous electrical cables (SELV circuits) by using a double resp. increased isolation.
All selected wires and isolations must be conform to the provided voltage- and temperature-ranges.
Further all country- and application-specific standards, which are relevant for structure, form and
quality of the wires, must be ensured. Indications about the permissible wire cross-sections for wiring
are described in the Technical Specifications.
Before first start-up it must be ensured that all connections and wires are firmly seated and secured in
the screw terminals. All (inclusively unused) terminals must be fastened by turning the relevant screws
clockwise up to the stop.
Overvoltages at the connections must be limited to values in accordance to the overvoltage category II.
For placement, wiring, environmental conditions as well as shielding and earthing/grounding of the
supply lines the general standards of industrial automation industry and the specific shielding
instructions of the manufacturer are valid.
Please find all respective hints and rules on
www.kuebler.com/download.html --> “[General EMC Rules for Wiring, Screening and Earthing]”.
1.4 Cleaning, Maintenance and Service Notes
To clean the front of the unit please use only a slightly damp (not wet!), soft cloth. For the rear no
cleaning is necessary. For an unscheduled, individual cleaning of the rear the maintenance staff or
assembler is self-responsible.
During normal operation no maintenance is necessary. In case of unexpected problems, failures or
malfunctions the device must be shipped for back to the manufacturer for checking, adjustment and
reparation (if necessary). Unauthorized opening and repairing can have negative effects or failures to
the protection-measures of the unit.

R60726.0002 – Index 4 EN - page 7
2.
Introduction
This series of display unit is suitable for analog signals (-10 … 10V or 0/4 … 20 mA). It is very versatile
in use, due to the intuitive handling and the extensive range of functions and options.
2.1
Operation mode
All functions are can be configured in the parameter menu.
The device can be set to one of the following operation modes:
•SINGLE:
single-channel operation of input 1
•DUAL:
two-channel operation of input 1 and 2
•IN 1 + IN 2:
two-channel operation of input 1 and 2 in combination with sum
•IN1 – IN 2:
two-channel operation of input 1 and 2 in combination with difference
•IN 1 x IN 2:
two-channel operation of input 1 and 2 in combination with multiplication
•IN 1 / IN 2:
two-channel operation of input 1 and 2 in combination with division

R60726.0002 – Index 4 EN - page 8
2.2
Function diagram

R60726.0002 – Index 4 EN - page 9
3.
Electrical Connections
The terminal screws should be tightened with a slotted screwdriver (blade width 2 mm).
3.1
DC Power Supply
The unit accepts DC supply from 18 to 30 V at the terminals 1 and 2. The power consumption depends
on the level of the supply voltage with approx. 100 mA and the additional current required at the
auxiliary voltage output.
All GND terminals are internally interconnected.
3.2
Auxiliary Voltage Output
Terminal 3 and 4 provide an auxiliary output for supply of sensors and encoders.
The output voltage depends on the power supply.
DC version
AC version
The encoder voltage is approx. 1 V lower than
the power supply voltage at terminal 1 and 2
and should be loaded with max. 250 mA.
The encoder voltage is 24 VDC (± 15%) and
should be loaded with max. 150 mA up to 45
degrees Celsius. At higher temperature the
maximum output current is reduced to 80 mA.

R60726.0002 – Index 4 EN - page 10
3.3
Analog Input
The reference potential (AGND) for the analog inputs is connected at terminal 5.
The unit provides two 16 bit analog inputs at terminal 6 and 7. The characteristics of the analog inputs
(voltage input or current input) can be set in the Menu IN 1/IN 2 PROPERTIES.
Important:
Before connecting the sensor the configuration (voltage or current input) must be set!
Wiring of the incremental inputs:
Voltage input
Current input
3.4
Reference Output
The unit provides a 10 V reference-output at terminal 8. This output should be loaded with 10 mA
maximum. This reference-output can be used for connecting a potentiometer.
Reference output with potentiometer