KStar HIP3300E User manual

All rights reserved.
The information in this document is subject to change without notice.
Publish statement
Thank you for purchasing this series UPS.
This series UPS is an intelligent, three phase in Three phase out, high frequency online
UPS designed by our R&D team who is with years of designing experiences on UPS.
With excellent electrical performance, perfect intelligent monitoring and network
functions, smart appearance, complying with EMC and safety standards, The UPS
meets the world’s advanced level.
Read this manual carefully before installation
This manual provides technical support to the operator of the equipment.

1
Contents
1.Safety ....................................................................................................................................... 2
1.1 Safety notes ....................................................................................................................................... 2
1.2 Symbols used in this guide ............................................................................................................ 2
2.Main Features ........................................................................................................................ 3
2.1 Summarization ................................................................................................................................... 3
2.2 Functions and Features .................................................................................................................. 3
3.Installation .............................................................................................................................. 4
3.1 Unpack checking .............................................................................................................................. 4
3.2 The appearance of the product ..................................................................................................... 4
3.3 Installation notes ............................................................................................................................ 15
3.4 External Protective Devices .......................................................................................................... 18
3.5 Power Cables ................................................................................................................................... 19
3.6 Power cable connect...................................................................................................................... 23
3.7 Battery connection ......................................................................................................................... 24
3.8 UPS parallel Installation ................................................................................................................ 25
3.8.1 Cabinet installation ............................................................................................................. 26
3.8.2 Parallel cable installation .................................................................................................. 26
3.9 LBS installation (optional) ............................................................................................................ 27
3.9.1 LCD setting ........................................................................................................................... 27
3.9.2 LBS cable installation ......................................................................................................... 27
3.9.3 UPS installation .................................................................................................................... 28
4.Operation .............................................................................................................................. 28
4.1 Operation Modes ............................................................................................................................. 28
4.2 Turn on/off UPS ............................................................................................................................... 31
4.2.1 Restart procedure ................................................................................................................ 31
4.2.2 Test procedure ..................................................................................................................... 31
4.2.3 Cold start procedure ........................................................................................................... 32
4.2.4 MAINTENANCE BYPASS ................................................................................................... 32
4.2.5 Shut down procedure ......................................................................................................... 33
4.2.6 Startup procedure for parallel system ........................................................................... 33
4.3 The Display ....................................................................................................................................... 34
4.4 Display Messages/Troubleshooting ........................................................................................... 64
4.5 Options .............................................................................................................................................. 66
Appendix 1 Specifications ..................................................................................................... 67
Appendix 2 Problems and Solution ..................................................................................... 72
Appendix 3 CAN communication port definition ............................................................. 74
Appendix 4 RS485 communication port definition ......................................................... 75
Appendix 5 COM communication port definition ............................................................ 75
Appendix 6 LBS port definition ............................................................................................ 76
Appendix 7 REPO instruction ............................................................................................... 76

2
1.Safety
Important safety instructions – Save these instructions
There exists dangerous voltage and high temperature inside the UPS. During the
installation, operation and maintenance, please abide the local safety instructions and relative
laws, otherwise it will result in personnel injury or equipment damage. Safety instructions in this
manual act as a supplementary for the local safety instructions. Our company will not assume the
liability that caused by disobeying safety instructions.
1.1 Safety notes
1. Even no connection with utility power, 220/230/240VAC voltage may still exist at UPS outlet!
2. For the sake of human being safety, please well earth the UPS before starting it.
3.Don’t open or damage battery, for the liquid spilled from the battery is strongly poisonous and
do harmful to body!
4.Please avoid short circuit between anode and cathode of battery, otherwise, it will cause
spark or fire!
5.Don’t disassemble the UPS cover, or there may be an electric shock!
6.Check if there exists high voltage before touching the battery
7.Working environment and storage way will affect the lifetime and reliability of the UPS. Avoid
the UPS from working under following environment for long time
◆ Area where the humidity and temperature is out of the specified range (temperature 0
to 40℃, relative humidity 5%-95%)
◆ Direct sunlight or location nearby heat
◆ Vibration Area with possibility to get the UPS crashed.
◆ Area with erosive gas, flammable gas, excessive dust, etc
8.Keep ventilations in good conditions otherwise the components inside the UPS will be
over-heated which may affect the life of the UPS.
1.2 Symbols used in this guide
WARNING!
Risk of electric shock

3
CAUTION!
Read this information to avoid equipment damage
2.Main Features
2.1 Summarization
This series UPS is a kind of three-in-three-out high frequency online UPS, it provides seven
specifications: The 100~1200kVA. The UPS can solve most of the power supply problems, such
as blackout, over-voltage, under-voltage, voltage sudden drop, oscillating of decreasing extent,
high voltage pulse, voltage fluctuation, surge, inrush current, harmonic distortion (THD), noise
interference, frequency fluctuation, etc..
This UPS can be applied to different applications from computer device, automatic equipment,
communication system to industry equipment.
2.2 Functions and Features
◆3Phase In/3Phase Out UPS
It is 3Phase In/3Phase Out high-density UPS system, of which input current is kept in balance.
No unbalance problem might occur.
◆Digital Control
This series UPS is controlled by Digital Signal Processor (DSP); enhance, it increases
reliability, performance, self-protection, and self-diagnostics and so on.
◆Battery Configurable from 30 blocks to 50 blocks
The battery voltage of this series UPS can be configured at 30 blocks, 32 blocks, 34 blocks, 36
blocks, 38 blocks, 40 blocks, 42 blocks, 44 blocks, 46 blocks, 48 blocks or 50 blocks according
to your convenience.
◆Charging Current is configurable
The user may set the capacity of the batteries as well as reasonable charging current.
Constant voltage mode, constant current mode or floating mode can be switched automatically
and smoothly.
◆Intelligent charging Method
The series UPS adopts advanced three-stage charging method—
1st stage: high current constant current charging
To guarantee to charge back to 90%;
2nd-stage: Constant Voltage
In order to vitalize battery and make sure batteries are fully charged
3rd stage: floating mode.
With this 3-stage charging method, it extends the life of the batteries and guarantees fast
charging.
◆Intelligent Monitoring Function
Via optional SNMP Card, you may remotely control and monitor the UPS.
◆Touch-screen Super-large LCD display

4
◆Equip with Maintenance Bypass Switch for easy maintenance purpose.
◆Superior MTTR (Meantime to repair) & Short shutdown time in maintenance
◆Centralized monitoring module is also available
◆EPO and REPO function
3.Installation
3.1 Unpack checking
1. Don’t lean the UPS when moving it out from the packaging
2. Check the appearance to see if the UPS is damaged or not during the transportation, do
not switch on the UPS if any damage found. Please contact the dealer right away.
3. Check the accessories according to the packing list and contact the dealer in case of
missing parts.
3.2 The appearance of the product
* Standard configuration : cabinet only with maintenance bypass switch
* Full configuration : cabinet with mains, bypass, maintenance and output switch
100kVA&120kVA&150K&160kVA(Full configuration), bottom entry
Front View Side View Rear View

5
Front View (internal) Front View (Copper bar)
200kVA & 250kVA & 300kVA (Full configuration) , bottom entry
Front View Side View Rear View

6
Front View (internal) Front View (Copper bar)
400kVA (Standard and Full configuration) , top or bottom entry
Front View Side View Rear View

7
400kVA(Standard and Full configuration) , top entry
Standard configuration Full configuration
Connect copper bar

8
400kVA(Standard and Full configuration) , bottom entry
Standard configuration Full configuration
Connect copper bar

9
400/500/600kVA(Standard and Full configuration), top and bottom entry
Front View Side View Rear View
400kVA(Standard and Full configuration) , top and bottom entry
Standard configuration Full configuration
Table of contents
Other KStar UPS manuals

KStar
KStar UDC9101S One User manual

KStar
KStar MEMO PLUS RT II (MP9100RTII-0.9) 1-3K User manual

KStar
KStar 6kVA User manual

KStar
KStar HPM3340 200k User manual

KStar
KStar UDC9100 Series User manual

KStar
KStar 1K User manual

KStar
KStar YMK3300-200k User manual

KStar
KStar 600 User manual

KStar
KStar YMK3300 Series User manual

KStar
KStar YDC9300-B User manual