Kospel HPM.Z User manual

Heat pump
HPM.Z
Assembly and operating instructions

This appliance can be used by children aged from 3 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Heat pump HPM.Z is a device hermetically
sealed and contains uorinated greenhouse
gases.

3
EN-102B_f.1296
Description
Heat pump HPM is a device used to heat/cool the building and heat the domestic hot
water.
Device is equipped with two units:
- outdoor unit HPMO, compressor heat pump.
Operation of the device is based on taking heat from the environment and forwarding
it to the heating circuit in the building. Low temperature air heat is transferred through
the evaporator into the heat pump system lled a refrigerant, which evaporated turns
to gas. The gas from the evaporator is sucked in by compressor, which raises its
temperature and transfers it when it is compressed to the condenser. In the condenser,
heat is transferred to the medium lling the central heating system, cooled liquid
ows through the expansion valve and goes back to the evaporator, whereupon the
whole process starts again. In the case of cooling, this cycle is reversed and heat is
extracted from the building and discharged outdoor.
- indoor HPMI unit with a built-in heating system controller.
The principle of operation of the device is based on the need-based regulation of
the capacity of the heat pump compressor with the switching of the electric heater
via the internal module controller. The indoor module control unit regulates the
rated power according to the set heating curve. If the heat pump is unable to cover
the building's heat demand on its own, the controller will automatically start the
additional electric heater which, together with the heat pump, produces the required
temperature of the heating medium.

4
Conditions for use and reliable operation of the device
1. Reading the contents of this instruction manual will enable proper installation and
operation of the device, ensuring its long-term and reliable operation.
2. The heat pump must be installed in accordance with the guidelines contained in
this user manual.
3. The HPM.P heat pump heating system consists of a set of optimally selected ele-
ments:
- HPMI indoor unit
- HPMO outdoor unit
- DHW cylinder SWPC
- SVK buffer tank
which guarantee the ecient and reliable operation of the HPM heat pump.
4. The manufacturer guarantees the correct operation and effective parameters of
the HPM heat pump only in cooperation with devices of the HPM.P.
5. The manufacturer is not responsible for the installation of the HPM heat pump with
other devices which may result in incorrect operation, lack of effective operating
parameters and increased operating costs of the heating system or a breakdown
of the HPM heat pump.
6. The manufacturer is not responsible for an incorrectly selected device to the heating
needs of the installation.

5
EN-102B_f.1296
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
12
12
14
14
15
15
16
16
17
17
18
18
11
11
13
13
[1] - ventilator
[2] - reversing valve
[3] - pressure switch
[4] - electromagnetic valve
[5] - compressor
[6] - liquid tank
[7] - service valve
[8] - heating medium inlet G1"
[9] - expansion valve
[10] - economizer
[11] - pressure transducer
[12] - heating medium outlet G1"
[13] - connection strip (PNL, modbus)
[14] - air vent socket (cork G1/2")
[15] - condenser
[16] - manometer
[17] - compressor controller
[18] - evaporator
Fig.1 Module HPMO

6
Fig. 2 Module HPMI
4
4
1
1
3
3
6
6
7
7
9
9
10
10
11
11
12
12
13
13
8
8
2
2
5
5
[1] - electrical connection
[2] - thermal cut-off
[3] - expansion vessel
[4] - automatic air vent
[5] - rated power
[6] - heating element
[7] - cooling circuit valve
[8] - safety valve
[9] - circulation pump
[10] - CH valve
[11] - DHW valve
[12] - control panel
[13] - device driver

7
EN-102B_f.1296
Heating and DHW mode with the heat pump switched off
When the outdoor temperature drops below the set shut-down temperature value,
the heat pump is automatically turned off and cannot produce heating water. In this
case, the heating and DHW mode is automatically performed by the additional electric
heater of the indoor unit.
Automatic defrost
Defrosting of the evaporator surface is done by reversing the refrigerant's circulation.
During the defrosting process the compressed gas is discharged from the compressor
to the evaporator, which melts the existing frost. The heating system cools down
slightly during this time. Duration the defrosting process depends on the degree of
frosting and the current external temperature. Active defrosting process is signaled
on the control panel by the icon .
Transport and storage
The HPMO heat pump should be transported and stored in a horizontal position.
Assembly
The heat pump is designed for outdoor installation and connection to indoor hydraulic
module with integrated additional electric heater. The device must be placed on a solid,
level base or foundation concrete. For fastening, use the attached vibration isolators.
To protect the device against snow and excessive moisture, base or the foundation
should protrude around 300mm above the ground level.
Prepare the ground under the foundation for free drainage of the condensate from
the drip tray. Drainage should be below the freezing zone. The layer thickness and
level must comply with local requirements and principles of construction technique.
The hole diameter should not be less than 100mm.
Condensate drain pipe should be thermally insulated. Thorough leveling the HPMO
outdoor unit will allow for free drainage of the condensate from the drip tray.
The heat pump should not be placed against the wall of rooms where noise could
interfere; e.g. by the bedroom wall. In order to maintain the high eciency of device it
is necessary to keep minimum distance against building's walls and other obstacles.
Restriction of the air ow can lead to the intake of cooled (heated in cooling mode)
air and lead to an increase in energy consumption of the compressor.
Connect the heating medium pipes to the heat pump and hydraulic module.

8
Noise
Sound pressure level for different distances from the device.
Power level
acoustic
Lw [dB (A)]
Directivity
factor
Q
Distance from the noise source r [m]
1 2 3 4 5 6 8 10 12 15
Sound pressure level Lp [dB (A)]
64
2 56 50 46 44 42 40 38 36 34 32
4 59 53 49 47 45 43 41 39 37 36
8 62 56 52 50 48 46 44 42 40 39
Q=2
Q=4
Q=8
Q = 2: freestanding heat pump on
the outside of the building.
Q = 4: heat pump on the building's wall.
Q = 8: heat pump on the building's wall
situated in the corner

9
EN-102B_f.1296
[1] - concrete foundation
[2] - gravel
[3] - the pipe for the condensate
[4] - gravel ground
[5] - base
[6] - vibration isolator
3
3
1
1
2
2
4
4
5
5
6
6
Fig.3 The assembly of outdoor unit HPMO
≥50cm
air inlet
air outlet
Proposed distance from right, left, top and behind wall - 50cm, front - 3m

10
Fig.4 The assembly of indoor unit HPMI
500 min.
300min.
300min.
47
47
34039
320
97
Ø50
49
418
751
617
7575 317
Ø35
Ø35
Ø35
4x dowel holes
expansion bolts
with a head
hexagonal
cable entry on
the left side
cover
cable entry
on the back
cover
480
50
location of the condensate drain socket
mounting screw spacing
649
330
12
354
874
36
1003
refrigerant manometer
heating medium
outlet G1"
air vent connection
electrical connection point
heating medium inlet G1"
109
603
65
709
Fig.4a The assembly of outdoor unit HPMO
Table of contents
Other Kospel Heat Pump manuals
Popular Heat Pump manuals by other brands

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Service manual

Dimplex
Dimplex LI 16I-TUR Installation and operating instruction

Carrier
Carrier WSHP Open v3 Integration guide

TGM
TGM CTV14CN018A Technical manual

Carrier
Carrier 38MGQ Series installation instructions

Kokido
Kokido K2O K880BX/EU Owner's manual & installation guide

Viessmann
Viessmann VITOCAL 300-G PRO Type BW 2150 Installation and service instructions

Carrier
Carrier 48EZN installation instructions

Viessmann
Viessmann KWT Vitocal 350-G Pro Series Installation and service instructions for contractors

Ariston
Ariston NIMBUS user manual

Weishaupt
Weishaupt WWP L 7 Installation and operating instruction

GE
GE Zoneline AZ85H09EAC datasheet