KEYTRONIX I-SAD 19"-S User manual

Introduction
1
I –SAD 19”-S
IP Security Access Device for 19” installation
Operating Instructions Version 1.9/SW 2.2

Introduction
2
Impressum:
KEYTRONIX
Gesellschaft für industrielle Elektronik und
Informationstechnologie mbH
Ungargasse 64-66/1/109
A - 1030 Vienna
Tel.: + 43 (1) 718 06 60 - 0
Fax: + 43 (1) 718 06 60 - 820
e-mail:
www.keytronix.com
HG Wien FN 261131t

Introduction
3
Table of Contents
1
I
NTRODUCTION
...................................................................... 4
2
I
-
SAD
19 "-
S
O
VERVIEW
..................................................... 7
2.1 Common Features....................................................................... 8
3
RS
232
I
NTERFACE
............................................................. 12
4
I
-
SAD
M
ODULES
............................................................... 13
4.1 I-SAD M I/O Modul..................................................................... 13
4.2 ISAD MI/O D-sub Modul............................................................ 18
4.3 I-SAD MCC Modul...................................................................... 23
4.4 AlEx – Alarm Extender.............................................................. 25
5
I
NSTALLATION
..................................................................... 29
6
C
ONFIGURATION
.................................................................. 33
6.1 WEB OPI..................................................................................... 33
6.1.1
LOGIN.............................................................................................34
6.1.2
Main menu.......................................................................................35
6.1.3
I-SAD (basic settings)......................................................................36
6.1.4
Temperature Sensor........................................................................40
6.1.5
Humidity Sensor..............................................................................41
6.1.6
Telnet..............................................................................................42
6.1.7
M I/O Module...................................................................................43
6.1.8
M I/O D-sub Module ........................................................................47
6.1.9
MCC Module ...................................................................................51
6.1.10
VLAN SETTINGS............................................................................54
6.1.11
VLAN TABLE...................................................................................55
6.1.12
ADMIN Bereich................................................................................57
6.2 OPI – Operator Interface........................................................... 60
7
S
AFETY
C
ONSIDERATIONS
.................................................... 71
8
A
BBREVIATIONS
.................................................................. 72

Introduction
4
1 I
NTRODUCTION
The I-SAD 19” is member of the
product family of
The reliable collection and secure transmission of operational data from
telecom network devices becomes more and more important. Operators face
rapid technology changes to their network infrastructure, creating challenges
for their operational support systems (OSS) to keep up. Individual and flexible
data collection solutions guarantee the optimal use of new transmission
technology to link to remote telecom equipment and sites.
Keytronix develops flexible systems that collect and transport device control,
status and alarm data to and from network operation centres.
The Alarm+Telemetry Controller product family offers optimized solutions
for your monitoring and control applications.
Alarm+Telemetry Controller – what is it?
It is a system that gathers alarms/events and control data of remote devices to a
central management system in a network operations center (NOC).
Figure 1: Alarm controller system overview
The alarm/telemetry controller detects alarms and events and transmits them to the NOC support
systems. It also passes telemetry data and operational control inputs from central management systems
to various equipment and devices installed at the remote sites.

Introduction
5
Figure 2: Alarm controller environment
The controller offers a variety of interfaces and connections to suit a wide range of devices. It integrates
easily into various environments through its electrical, Physical and functional connections. This makes
it an ideal choice for remote operation monitoring and remote control of mission critical applications.
Figure 3: Alarm controller functional architecture

Introduction
6
Typical Application:
Remote monitoring and controlling of systems located in an unmanned telecom site
(POP).
Figure 4: Remote site configuration
This includes site security access systems, room surveillance systems, facility
control systems (e.g. climate control, power supply) and telecoms equipment
(e.g. fiber transmission systems, routers, switches, servers and media
gateways). These systems are connected to the alarm + telemetry controller
that transmits events and data bidirectional to the provider NOC.
The controller integrates into existing network management systems and
trouble ticketing systems via the SNMP protocol.

I - SAD 19 "- S Overview
7
2 I
-
SAD
19 "-
S
O
VERVIEW
The IP Security Access Device
I-SAD 19“- S is a highly modular remote control system, with the ability to
transmit Alarm data, Switch/Relays Operations and Telemetry-data of the
customer over a secured TCP/IP connection. The connection is established
over Ethernet-LAN or as an alternative wirelessly over an optional M – GSM
over GPRS mountable module.
Additional features are the control of temperature and humidity sensors.
Access to third party equipment (with implemented asynchronous interface)
can be realized by connecting them to RS-232 interface on the I-SAD 19”
front panel.
The configuration, control and evaluation/reporting of the I-SAD 19“device
can be carried over the Ethernet Interface via
•integrated WEB Operator Interface
•SNMP
or over a local asynchronous Operator Interface (OPI) designed as a
Command Line Interface (CLI).
Application
Connection of external Sensors and/or different peripheral Alarms I/Os for
monitoring and surveillance on a remote IP-Desktop.

I - SAD 19 "- S Overview
8
2.1 Common Features
Management
HTML - based WEB OPI
SNMP V2c for sending of event - messages, administration of the device and
remote control of the input and outputs (I/Os).
DHCP client or static IP address
up to 3 destination addresses for SNMP traps possible
free editing of READ/WRITE communities
Physical
Form factor: 19” 1HU
Dimensions: 483 x 45 x 205 (W x H x L) mm
Front view

I - SAD 19 "- S Overview
9
Ethernet Switch:
The I-SAD 19“-S is equipped with an integrated Ethernet - Switch. It is used
to switch the data between the four Ports.
the 4 Ports:
•NMS is an internal Port, which is connected to the CPU.
•ETH1 10/100BT Interface on the front of the device
•ETH1 10/100BT Interface on the front of the device
•SFP Plugin – slot for SFP plugin modules
Technical specification of the Ethernet –Switch:
•Ethertype: 8100 Hex
•Up to 1024 Mac- addresses
•max. Framesize: 1522bytes
•VLAN according to 802.1 Q/P
- max. 64 different VLANs - entries
- VLAN ID: 0 – 4095
Displays/ LEDs
Alarm red Is on if the device detects an alarm
PWR green “Power” is flashing when the device is
booting and lights up if the device is ready for
use
TEMP green Sensor is connected
yellow temperature interval failure
HUMIDITY green Sensor is connected
yellow relative humidity failure
SFP LNK Is on if the line is synchronised
ACT Is on if data is transmitted
Ethernet /
LAN Interface green Link/Act
yellow on = 100, off = 10MBit/s

I - SAD 19 "- S Overview
10
Interfaces
SFP SLOT for one 100FX SFP (Small Factor Plugin) for LAN access
The warranty is satisfied with the following SFP´s:
APACOE LS38-C3S-TI-N-D3 SM1310/1550 10km
IMC 808 -38103 IE-SFP SM1310 20km
IMC 808-38101 IE-SFP MM850 2KM
ETH 1+2 (LAN, WEB-OPI Operator Interface, Ethernet Connector, auto -
detected)
TEMP RJ 45- Connector for connecting a Keytronix I-SAD TS (0708-
6201) or RITTAL temperature - sensor
HUMITIDY RJ 45- Connector for connecting a Keytronix I-SAD HS (0708-
6101) or RITTAL humidity – sensor