Keysight Technologies N5991 User manual

User Guide
Keysight N5991 HDMI Frame
Generator

Notices
© Keysight Technologies 2020
No part of this manual may be reproduced
in any form or by any means (including
electronic storage and retrieval or transla-
tion into a foreign language) without prior
agreement and written consent from
Keysight Technologies as governed by
United States and international copyright
laws.
Manual Part Number
N5991-91500
Edition
Edition 1.0, March 2020
Keysight Technologies Deutschland GmbH
Herrenberger Strasse 130,
71034 Böblingen, Germany
Technology Licenses
The hardware and/or software described in
this document are furnished under a
license and may be used or copied only in
accordance with the terms of such license.
U.S. Government Rights
The Software is “commercial computer
software,” as defined by Federal Acquisition
Regulation (“FAR”) 2.101. Pursuant to FAR
12.212 and 27.405-3 and Department of
Defense FAR Supplement
(“DFARS”) 227.7202, the U.S. government
acquires commercial computer software
under the same terms by which the soft-
ware is customarily provided to the public.
Accordingly, Keysight provides the Soft-
ware to U.S. government customers under
its standard commercial license, which is
embodied in its End User License Agree-
ment (EULA), a copy of which can be found
at http://www.keysight.com/find/sweula.
The license set forth in the EULA represents
the exclusive authority by which the U.S.
government may use, modify, distribute, or
disclose the Software. The EULA and the
license set forth therein, does not require
or permit, among other things, that Key-
sight: (1) Furnish technical information
related to commercial computer software
or commercial computer software docu-
mentation that is not customarily provided
to the public; or (2) Relinquish to, or other-
wise provide, the government rights in
excess of these rights customarily provided
to the public to use, modify, reproduce,
release, perform, display, or disclose com-
mercial computer software or commercial
computer software documentation. No
additional government requirements
beyond those set forth in the EULA shall
apply, except to the extent that those
terms, rights, or licenses are explicitly
required from all providers of commercial
computer software pursuant to the FAR and
the DFARS and are set forth specifically in
writing elsewhere in the EULA. Keysight
shall be under no obligation to update,
revise or otherwise modify the Software.
With respect to any technical data as
defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS 227.7102,
the U.S. government acquires no greater
than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as appli-
cable in any technical data.
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED "AS IS," AND IS
SUBJECT TO BEING CHANGED, WITHOUT
NOTICE, IN FUTURE EDITIONS. FURTHER,
TO THE MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, KEYSIGHT DISCLAIMS
ALL WARRANTIES, EITHER EXPRESS OR
IMPLIED WITH REGARD TO THIS MANUAL
AND ANY INFORMATION CONTAINED
HEREIN, INCLUDING BUT NOT LIMITED TO
THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. KEYSIGHT SHALL
NOT BE LIABLE FOR ERRORS OR FOR
INCIDENTAL OR CONSEQUENTIAL
DAMAGES IN CONNECTION WITH THE
FURNISHING, USE, OR PERFORMANCE OF
THIS DOCUMENT OR ANY INFORMATION
CONTAINED HEREIN. SHOULD KEYSIGHT
AND THE USER HAVE A SEPARATE
WRITTEN AGREEMENT WITH WARRANTY
TERMS COVERING THE MATERIAL IN THIS
DOCUMENT THAT CONFLICT WITH THESE
TERMS, THE WARRANTY TERMS IN THE
SEPARATE AGREEMENT WILL CONTROL.
Safety Notices
CAUTION
A CAUTION notice denotes a hazard. It
calls attention to an operating proce-
dure, practice, or the like that, if not
correctly performed or adhered to,
could result in damage to the product
or loss of important data. Do not pro-
ceed beyond a CAUTION notice until
the indicated conditions are fully
understood and met.
WARNING
A WARNING notice denotes a hazard. It
calls attention to an operating proce-
dure, practice, or the like that, if not
correctly performed or adhered to,
could result in personal injury or death.
Do not proceed beyond a WARNING
notice until the indicated conditions
are fully understood and met.
2Keysight N5991 HDMI Frame Generator User Guide

Keysight N5991 HDMI Frame Generator User Guide 3
Contents
1 Introduction
Overview of the Guide 6
Document History 7
First Edition (March 2020) 7
HDMI Frame Generator - Overview 8
2 Test Instrument Setup
M8195A Single Module setup 10
M8195A Two Module setup 11
3 Using the Software
Connecting to the Instruments 14
Main window 18
TMDS Mode 19
FLR Mode 28
Video Format 29
Link Training Pattern selection 29
Save / Load Settings dialog 30
Main menu 31
4 Troubleshooting

4Keysight N5991 HDMI Frame Generator User Guide
Contents

6Keysight N5991 HDMI Frame Generator User Guide
1 Introduction
Overview of the Guide
This guide provides a detailed description of the Keysight N5991 HDMI
Frame Generator.

Keysight N5991 HDMI Frame Generator User Guide 7
Introduction 1
Document History
First Edition (March 2020)
The first edition of this user guide describes functionality of software
version 1.0.

8Keysight N5991 HDMI Frame Generator User Guide
1 Introduction
HDMI Frame Generator - Overview
The HDMI (High-Definition Multimedia Interface) Frame Generator
software (also known in short as “Frame Generator” or “software”) is a
stand-alone software utility. It provides semi-automatic control of Keysight
Technologies’ M8195A AWG (Arbitrary Waveform Generator) TMDS and
FRL Signal Generator for physical layer tests.
The Frame Generator is a flexible tool for trouble-shooting and debugging.
it complements the full Test Automation Software (N5991HP1A), which
provides automated physical layer compliance tests and device
characterization. It allows a wide range of HDMI video formats to be
generated and provides control over parameters such as color depth and
color code. It comprises jitter insertion for jitter tolerance tests to set the
skew and other key parameters. The software runs on a standard Windows
PC and controls the hardware test resources through appropriate
interfaces, such as a LAN (Local Area Network).

Keysight N5991 HDMI Frame Generator
User Guide
2Test Instrument Setup
M8195A Single Module setup / 10
M8195A Two Module setup / 11
Prior to using the HDMI Frame Generator software for connecting
instruments, Keysight recommends setting up the test instruments and
establishing the required connections.
1 Connect the instruments (AWG and other instruments, such as, signal
and waveform generators) to the controller PC via USB or LAN.
2 Establish all required cable connections between the instruments and
the DUT (device under test).
3 Switch on the PC and instruments.
4 Start Keysight “IO (Input Output) VISA (Virtual Instrument Software
Architecture) connection Expert” and check the connections for the
instruments.
5 Set the correct IP addresses for the instruments.
The AWG setup can be used in two different configurations:
• based on single M8195A module (TMDS only)
• based on two M8195A modules and an M8197A synchronization
module

10 Keysight N5991 HDMI Frame Generator User Guide
2 Test Instrument Setup
M8195A Single Module setup
This setup consists of a limited HDMI test configuration.
It does not have any instrument intra-pair skewing capability, can only
reach up to around 8Gbit/s and does not support FRL testing.
Figure 1 Connection diagram for an M8195A single module setup
For a full coverage of HDMI PHY testing, the M8195A two module setup
(shown further) is required.
Other manuals for N5991
1
Table of contents
Other Keysight Technologies Inverter manuals

Keysight Technologies
Keysight Technologies E4360A User manual

Keysight Technologies
Keysight Technologies E8257D User manual

Keysight Technologies
Keysight Technologies Y1165A User manual

Keysight Technologies
Keysight Technologies P9336A User guide

Keysight Technologies
Keysight Technologies 81133A User manual

Keysight Technologies
Keysight Technologies 81160A User manual


















