Kensence FMX Series User manual

1
FMX Flexible Matrix Switcher
Operation manual
Kensence (Shenzhen) Technology Development CO.,LTD
Version:V1.01.01
2016-4

2
Content
1.Introduction........................................................................................ - 1 -
2.Features............................................................................................. - 1 -
3.System connection........................................................................... - 1 -
4.Standard configuration.................................................................... - 2 -
5.Specification...................................................................................... - 3 -
6.Device panel description................................................................. - 4 -
7.Card introduction.............................................................................. - 6 -
8.Matrix control operation introduction...........................................- 13 -
8.1Panel control........................................................................... - 13 -
8.2 RS232 Control.......................................................................- 14 -
8.3 TCP/IP communication port control...................................- 22 -
9.USB firmware upgrade.................................................................. - 31 -
10.Common faults and maintenance............................................. - 32 -
11.After-sales service........................................................................- 34 -

3
To protect the device and operating personnel from electrostatic discharge, you need to
check and ensure that the device is grounding good before the device is powered on.
Please observe the following when you install, use, maintain this equipment.
Make sure the device ground connection.
Please use single-phase three wire system AC 220V power supply, and ensure all
transmission system is grounding good.
To protect operating personnel and the device ,please turn off all power supplies and
pull the plug before moving the device or doing some specific works witch need to be
done when the electricity is turned off . Please turn off the main power switch on rainy
days or when not in use for a long time.
Please do not put anything upon the cables, or tread the cables .
To avoid damaging the device , please turn off power supply before plugging cable into
the device or pulling cable from device. The damage caused by plugging/ pulling cables
without turning off power supply is outside the scope of the warranty.
The power of the device gives out heat when it works, so it’s necessary to keep the
work environment ventilated to protect the device from the damage caused by
Safety Reminder

4
overtemperature.
Do not place the device in very cold or very hot places. Do not sprinkle any corrosive
chemicals or liquid on or around the device.
To avoid accident or any further damage ,non-professionals please do not dismantle or
maintain the device without permission.
Do not sprinkle any corrosive chemicals or liquid on or around the device.

1.Introduction
FMX16/FMX32 is a new type of HD seamless modular matrix of one card one
single , which supports a total of 16/32 HD video. The 12 / 24 channels can be customized
input / output mode, of which 4/8 channel is fixed output. It can automatically detect of
card type and support different input and output channel number.The system support
HDMI, DVI, VGA, SDI, YPBPR, CVBS, HDBaseT, HDCI and other signals, can customize
the output resolution, the highest is 1920*1200@60Hz. It also adopts seamless switching
technology, making the switching process without black, blue, tearing, jitter and so on.It
can be widely used in government, judicial, military, education, medical, business and
other occasions.
2.Features
Modular design, support HDMI, DVI, SDI, HDBT, HDCI signal card, VGA & Audio
cards and can be free to match, improves system flexibility;
Compatible with HDCP2.2 and HDCP1.4;
Support PCI-E 32 slots
Available with choice of I/O cards, Free configuration from 1x38 to 24x8 (FMX 32),
from 1x15 to 12x4 (FMX16)
Automatically detected input/output signal card.
Support PoH
Scaling technology
Support seamless switching (4k);
Flexible control mode, with key panel (button) operation, GUI, RS232 control
function, network port control function, infrared control function, etc.;
Using LCD screen displays real-time working status;
Support scene save and call function;
Support EDID learning function;
Automatic detection of input and output cards;

3.System connection
1.Connect signal source such as blu-ray player、game controller、A/V receiver、cables、
satellite receiver etc. to input port,when plug in and out of the card, please be careful to
operate in case of damaging the circuit when the matrix is power on.
2.Connect the output port to HD display such as HDTV or HD projector.
3.Firstly power on the signal source,then the matrix(with power supply),finally devices
connected to the output port .
4.Plug in power to each device in the same order .

4.Standard configuration
Please check the outer package before using this product. Please contact us if the
product is faulted or not intact. We will sincerely serve you according to relevant
provisions.
NO.
Name
Quantity
Unit
1
Matrix Host
1
pcs
2
Dryer 50g
1
pcs
3
AC power adapter
2
pcs
4
Certification
1
pcs
5
Warranty card
1
pcs
6
User manual
1
pcs

5.1 Specification
Model
FMX16
Description
16 card enhanced HD modular matrix
Card slot
16 card of 12 arbitrary combination and 4 fixed output
Input module
Support CVBS, YPbPr, VGA, HDMI, DVI, AUDIO, 3GSDI, HDCI, HDBase T
Output
Module
Support CVBS, YPbPr, VGA, HDMI, DVI, AUDIO, 3GSDI, HDCI, HDBase T
Bandwidth
10.2 Gbps
Serial port
control
Control protocol : RS232(baud rate : 115200 data bits:8 stop bit 1:no parity
Connector : 9 pin D-sub(DE9F) jack2=TX 3=RX 5=GND
Network IP
Control protocol : TCP/IP Connector : RJ45 connector 10/100 Base-T Ethernet
Color space
Supports RGB444, YUV444, YUV422 color space, supports x.v.Color extended
gamut standard
Electrostatic
protection
Human body discharge mode: ±8kV (air gap discharge)
± 4kV (contact discharge)
Input Voltage
100 VAC-260 VAC, 50/60 Hz,international adaptive power supply
23W(max)/0.5w(Standby state)
Operating
Temperature
-10℃---50℃
Storage
Temperature
-20℃---60℃

5.2 Specification
Model
FMX32
Description
32 card enhanced HD modular matrix
Card slot
32 card of 24 arbitrary combination and 8 fixed output
Input module
Support CVBS, YPbPr, VGA, HDMI, DVI, AUDIO, 3GSDI, HDCI, HDBase T
Output
Module
Support CVBS, YPbPr, VGA, HDMI, DVI, AUDIO, 3GSDI, HDCI, HDBase T
Bandwidth
10.2 Gbps
Serial port
Control protocol : RS232(baud rate : 115200 data bits:8 stop bit 1:no parity
Network IP
Control protocol : TCP/IP Connector : RJ45 connector 10/100 Base-T Ethernet
Color space
Supports RGB444, YUV444, YUV422 color space, supports x.v.Color extended
gamut standard
Electrostatic
Human body discharge mode: ±8kV (air gap discharge)
± 4kV (contact discharge)
Input Voltage
100 VAC-260 VAC, 50/60 Hz,international adaptive power supply
23W(max)/0.5w(Standby state)
Operating
Temperature
-10℃---50℃
Storage
Temperature
-20℃---60℃

6.Device panel description
Fig 6.1.1 FMX32 front panel
1.Micro USB interface: through the interface to upgrade the firmware;
2.Power indicator, when switch on it's always bright;
3.LCD screen: display real-time operating status;
4.INPUT and OUTPUT Key area;
5.function key area: including "ALL" select button. " EDID" button." CLEAR"
button,"ENTER" button this four buttons.
Fig 6.1.2 FMX32 rear panel
This manual suits for next models
2
Table of contents
Other Kensence Matrix Switcher manuals