JABSCO 34739 series User manual

Model 34739-Series
(NOTICE: Tighten screws evenly to avoid flange
damage). Use outlet collar No.34856-0000 to connect
ducting to discharge vent. Use a suitable discharge fitting
so that static pressure of blower will not be affected by
change in wind direction. Route inlet ducting with as few
bends as possible to lower 1/3 of bilge compartment
where vapors are likely to accumulate.Be sure ducting is
positioned below top of engine stringers but not so low
as to become submerged in bilge water.Locate pickup to
take advantage of natural air flow direction.Flexible duct-
ing No.34959-0100 is easy to cut and install.
NOTICE: Blower should be mounted away from
extreme heat (more than 130°F) to prevent distortion of
blower wheel or housing.
For an exposed inlet, ventilator intake screen No.34764-0000
provides a safe and attractive protected inlet. NOTE:
This blower may also be mounted with inlet through bulk-
head, using intake collar No. 34943-0000.
Jabsco blowers are primarily intended for intermittent
duty cycles such as evacuating fuel vapors from bilge
areas. If desired, they also may be used for other general
air circulation applications with longer duty cycles.
However, when doing so, it should be noted that the
maximum motor life is approximately 1000 hours.
Therefore, the blower should only be used for
applications if this length of service is acceptable.
OPERATION: See following warning placard statement:
The “WARNING” placard supplied with blower must
be mounted adjacent to engine ignition switches (all
Locations) to comply with Title 33, Part 1834;
Subpart K, USCG Ventilation Regulations.*
*Additional warning placards are available from factory by requesting
form 43003-0418.
FLANGEMOUNT 3"BLOWER
FEATURES
●Tough Reinforced Plastic Housing
●Mount to Any Flat Surface
●Slip-On Inlet Ducting Connection
●Efficient High Volume Air Flow
●Low-Current Draw
●Corrosion-Resistant Materials Throughout
●N.M.M.A.Type Accepted
●DC Models Comply with USCG Electrical
Regulations of Title 33, Chapter I, Part 183; Subpart I
and ISO 8846 MARINE for Ignition Protection
●DC Models Comply with ISO 9097 Marine
●DC Models Conform with EN 50081-1 for
Suppression of Electromagnetic Interference
SPECIFICATIONS
Air Fuse Weight
Model Flow Voltage Amps Size lb(kg)
34739-0010 150 CFM 12 Vdc 6.5 10A 5
(4.0 m3/min.) (2.3)
34739-0020 150 CFM 24 Vdc 3.3 5A 5
(4.2 m3/min.) (2.3)
34739-0031 150 CFM 115 Vdc 0.8 1.25A 5
(4.0m3/min.) 125V (2.3)
WIRING FOR DC MODELS: Use stranded copper wire.
For lengths up to 25 feet (7.6m) from power source: Use
12 gauge wire for 12 Volt and 14 gauge wire for 24 Volt.
Use larger wire for longer lengths. Use a 10 amp rated
on-off switch in positive side of circuit (Model 44960-
0003). Circuit must be protected with a fuse.Suggested
fuse sizes are listed in the specifications table.
WIRING FOR AC MODEL: Use 16 gauge stranded
copper wire for lengths up to 100 feet from power
source. Connect the grounded, unswitched conductor
(white) to the white motor lead.Connect the undergrounded,
switched conductor (black) to the black motor lead. This
conductor should include, at the power source, a 1.25
amp 125 Volt fuse. The green motor lead must be
connected to the AC circuit ground.
INSTALLATION
INSTALLATIONS MUST MEET APPLICABLE
SECTIONS OF TITLE 33, PART 183; SUBPART K,
USCG VENTILATION REGULATIONS.
MOUNTING: Mount blower on flat bulkhead surface in
highest part of compartment free from spray or deck
wash. Cut 2-3/4" hole in bulkhead and secure blower
with washers and No. 10 screws.
Model 34739-Series

Bulkhead
Inlet
Ducting
Outlet collar 34856-0000
for 3" ducting
3" Ducting
34959-0100
To Discharge Vent
INSTALLATION DRAWING


U.S.A.
Jabsco
Cape Ann Industrial Park
Gloucester, MA 01930
Tel: 978.281.0440
Fax: 978.283.2619
UNITED KINGDOM
Jabsco
Bingley Road, Hoddesdon
Hertfordsire EN11 OBU
Tel: +44 (0) 1992 450145
Fax: +44 (0) 1992 467132
CANADA
Fluid Products Canada
55 Royal Road
Guelph, Ontario N1H 1T1
Tel: (519) 821.1900
Fax: (519) 821.2569
JAPAN
NHK Jabsco Company Ltd.
3-21-10, Shin-Yokohama
Kohoku-Ku, Yokohama, 222
Tel: 045.475.8906
Fax: 045.475.8908
GERMANY
Jabsco GmbH
Oststrasse 28
22840 Norderstedt
Tel: +49-40-53 43 73 -0
Fax: +49-40-53 53 73 -11
THE PRODUCTS DESCRIBED HEREIN ARE
SUBJECT TO THE JABSCO ONEYEAR LIMITED
WARRANTY, WHICH IS AVAILABLE FORYOUR
INSPECTION UPON REQUEST.
© Copyright 2003, ITT Industries Printed in U.S.A. All Rights Reserved Form: 43000-0399 Rev. 10/2003
MARINE SWITCH PANELS
44960-0002
Lighted Switch with Boot
SPST
44960-0003
Unlighted SPST
MARINE SWITCH PANELS
These rocker switch panels are available in an attractive
black textured finish. Select between two models with or
without illumination.All lighted models are complete with
silicon seal boot.
44960-0002 and 44960-0003 include durable stick-on
labels for all popular screws.
Model # Position Elec. Rating
44960-0002 2 (on, off lighted) 10 amps/12 Vdc
44960-0003 2 (on, off unlighted) 10 amps.6-32 Vdc
10 amps/110 Vdc
3
(76)
6-3/4 (171) A
2-3/4
(70)
7-7/8
(200)
DIMENSIONAL DRAWING
Inches (Millimeters)
Model Dimension A
34739-0010 7-7/8" (200)
34739-0020 7-7/8" (200)
34739-0031 8-3/8" (213)
PARTS LIST
Part
Key Description Qty. Number
1 Motor Kit 1
12 VDC 30200-0000
24 VDC 30200-0010
32 VDC 30200-0020
115 VDC 30200-0050
2Blower Housing 1 35744-0000
3 Blower Wheel 1 34742-0000
4 Blower Housing 1 35775-0000
5 Screw 8 x 5/8 SS Self 5 35508-0000
Tapping Pan Head
2
3
45
1
1
PARTS VIEW
This manual suits for next models
3
Table of contents
Popular Fan manuals by other brands

ELTA FANS
ELTA FANS H03VV-F installation guide

Hunter
Hunter 20714 Owner's guide and installation manual

Emerson
Emerson CARRERA VERANDA CF542ORB00 owner's manual

Hunter
Hunter Caraway Owner's guide and installation manual

Panasonic
Panasonic FV-15NLFS1 Service manual

Kompernass
Kompernass KH 1150 operating instructions