ITW Simco-Ion Aerostat XC User manual

IONIZATION SOLUTIONS
Ionizing Air Blower
Aerostat®XC
User’s Manual

Aerostat XC Heater 5100550-M Rev 7
About Simco-Ion
Simco-Ion develops, manufactures, and markets system solutions
to manage electrostatic charge. As the world's largest provider of
electrostatics management products and services, Simco-Ion
improves its customers' business results by providing a total
solution to their electrostatic discharge and electromagnetic
interference challenges. Simco-Ion Technology Group is a division
of Illinois Tool Works (ITW), located in Alameda, California. For
more information about Simco-Ion visit www.simco-ion.com
(Technology Group) or call +1 800-367-2452. Simco-Ion is
ISO 9001-2008 Certified.
Ion Systems’ logo is a registered trademark of
Simco-Ion, An ITW Company.
© 2019 Ion Systems. Printed in the USA.
© 2019 Simco-Ion

Aerostat XC Heater 5100550-M Rev 7
Important Safety Information
This unit is supplied with a 3-prong grounding plug, which must
be inserted in an appropriate, properly wired, and grounded
receptacle. Do not defeat the electrical ground. Grounding and
proper wiring are required for safe and efficient operation.
Keep the unit dry. Do not operate the ionizer in flammable, or
explosive atmospheres.
Do not insert objects through the unit's intake or outlet grilles.
Damage to the ionizer and/or personal injury may result.
Do not ground or make electrical connections of any kind to the
unit's metal fan guards located on the intake and output.
A factory-qualified service technician must perform component
service and repairs. Please contact Simco-Ion Customer
Service for information.
Carefully read the following safety information before
installing or operating the equipment. Failure to follow
these safety warnings could result in damage to your
ionization system and/or voiding the product warranty.

Aerostat XC Heater 5100550-M Rev 7
Informations de Sécurité Importantes
Cette unité est fournie avec un 3-broches fiche de mise à la
terre, qui doit être insérée dans un approprié, correctement
câblé et boîtier raccordé à la terre. Ne pas défaire la mise à la
terre électrique. La mise à la terre et le câblage correct sont
requises pour un fonctionnement sûr et efficace.
Garder l'unité sec. Ne pas faire fonctionner le ioniseur, inflam-
mables ou atmosphères explosives.
N'insérez pas d'objets dans l'unité de grilles d'entrée ou de
sortie. Dommage pour l'ioniseur et/ou peut entraîner des bless-
ures graves.
Ne porter pas à la masse ou des connexions électriques de
toute nature à l'unité en métal de protections du ventilateur situé
sur l'admission et la sortie.
Usine d'un technicien qualifié doit effectuer composant service
et réparations. Veuillez contacter Simco-Ion Service client pour
plus d'informations.
Lisez attentivement les consignes de sécurité
suivantes avant d'installer ou d'utiliser l'équipement. Le
non-respect de ces avertissements peut entraîner des
dommages à votre système d'ionisation et/ou d'annuler
la garantie du produit.

Aerostat XC Heater 5100550-M Rev 7
Contents
1 Description .......................................................................... 1
1.1 Aerostat® XC Ionizing Air Blower ............................................................ 2
1.2 Aerostat XC Identification ........................................................................ 4
2 Installation ........................................................................... 5
2.1 Unpacking ................................................................................................ 6
2.2 Location ................................................................................................... 7
2.3 Electrical ................................................................................................. 8
3 Operation ............................................................................. 9
3.1 Controls & Indicators.............................................................................. 10
4 Maintenance ...................................................................... 12
4.1 Cleaning & Adjustments......................................................................... 13
4.2 Emitter Cleaning .................................................................................... 14
4.3 Air Inlet & Outlet Cleaning...................................................................... 15
4.4 Optional Air Filter Cleaning....................................................................16
4.5 Ion Output Check...................................................................................17
4.6 Ion Balance Check................................................................................. 18
4.7 Calibration.............................................................................................. 19
5 Specifications.................................................................... 20
6 Warranty & Service .......................................................... 25

Aerostat XC Heater 5100550-M Rev 7 2
1.1 Aerostat®XC Ionizing Air Blower
Simco-Ion's Aerostat XC was designed for use with sensitive
electronic components where electrostatic discharge (ESD) is a
problem. It can be applied in inspection, testing, and assembly
environments. The Aerostat XC can also be used where static
electricity causes problems such as attraction of dirt to product,
misalignment of small parts due to electrostatic "jumping", and
undesirable adhesion of plastic films due to electrostatic charge.
The Aerostat XC ionized air blower produces an air flow that is rich
in positive and negative ions. Directing the air flow on an object that
has a static charge will neutralize the charge. If the object has a
positive static charge, it will draw negative ions from the air flow. If
the object has a negative static charge, it will draw positive ions from
the air flow. The ions are attracted to the oppositely charged object
and neutralize the electrostatic charge on the object.
Figure 1. Aerostat XC Ionizing Air Blower
The Aerostat XC uses a three-speed tangential blower to produce a
uniform air flow. This air flow is directed into a duct, which shapes
the airflow. The duct also contains a heater and ionizer. The low-
wattage heater can be turned on at any time for user comfort. The
ionizer uses a transformer which produces high voltage AC. The
transformer output contains a current limiting resistor which
provides redundant safety and enhances the ionization stability.

Aerostat XC Heater 5100550-M Rev 7 3
The high voltage AC is applied to a row of stainless steel emitter
pins, which results in an intense alternating electric field at the tip of
the emitters. It is this intense electric field that introduces alternating
polarity ions into the air flow. The shaped air flow exiting the
Aerostat XC carries these ions over a broad area for control of
electrostatic charge. To ensure that the unit is working properly, the
output is monitored by an ionization indicator lamp.
The ionizer of the Aerostat XC features an exclusive balancing
circuit. This results in the equal production of positive and negative
ions. The Aerostat XC also features a built-in emitter cleaner.
Taking a few seconds to clean the emitters on a weekly basis
prevents the build-up of debris on the emitter pins, keeping your
AeroStat, keeping your Aerostat XC working in top form for the life
of the unit.
Features
• Rapidly neutralizes static charges
• Covers an extended area with ionized air
• Three-speed fan with wide range of air flow
• Low-wattage heater for operator comfort
• Tilt Bench stand, or optional pedestal mount.
• Inherently balanced ion output
• Built-in ion emitter cleaner
• Ionization indicator lamp
• Durable, electrically grounded steel enclosure

Aerostat XC Heater 5100550-M Rev 7 4
1.2 Aerostat XC Identification
Figure 2. Aerostat XC Identification
Table of contents
Other ITW Blower manuals

ITW
ITW SIMCO ION 5802i User manual

ITW
ITW SIMCO ION AEROSTAT XC User manual

ITW
ITW Ion Systems 6422e User manual

ITW
ITW ION SYSTEMS 6432e User manual

ITW
ITW Simco Ion IQ Power Fantom HL User manual

ITW
ITW SIMCO ION Aerostat Guardian User manual

ITW
ITW SIMCO ION Aerostat PC2 User manual

ITW
ITW SIMCO-ION Phoenix User manual