InWin IW-RS104-02M User manual

IN WIN DEVELOPMENT
Passive SAS/SATA Backplane User Manual
Supported Devices
Part Number
Description
3RAMVI005500
3RAMVI005600
IW-RS104-02M / IW-RS104-02SN PASSIVE BACKPLANE MODULE
3RAMVI006000
2RAKVI001000
IW-RS110-02M PASSIVE BACKPLANE MODULE
3RAMVI006200
2RAKVI001200
IW-RS208-02M PASSIVE BACKPLANE MODULE
3RAMVI006300
2RAKVI001300
IW-RS212-02M PASSIVE BACKPLANE MODULE
3RAMVI006100
2RAKVI001100
IW-SK34 PASSIVE BACKPLANE MODULE
(IW-MS04/IW-MS08/IW-MS08-A/IW-PLV Tower/IW-PLG Tower)
3RAMVI005900
IW-SK35 PASSIVE BACKPLANE MODULE
(IW-R400-03N)
Draft Version: 0.2

History
Version
Changes
Date
0.1
First draft
2017/4/17
0.2
SGPIO setting behavior change
2017/5/9

Table Of Contents
1Overview............................................................................................................................ 4
2Jumper Settings................................................................................................................. 5
3Connectors ........................................................................................................................ 8
3.1 29-pin SAS HDD connector........................................................................................... 8
3.2 SFF-8643 Mini-SAS connector: ..................................................................................... 9
3.3 4-Pin power receptacle .............................................................................................. 10
4LED and Buzzer Behavior................................................................................................. 11
4.1 Disk Bay LED........................................................................................................... 11
4.2 System Alarm LED .................................................................................................. 12
5. Smart Fan Control............................................................................................................ 14
6. Firmware Upgrade........................................................................................................... 17

1Overview
IN WIN backplanes (without Expander) are high performance economical 8 solution
for users who has adequate SAS connection ports on motherboard or RAID/HBA card
to accommodate the disks in the system.
The passive backplanes support state-of-the art SAS3 12Gbps HDD/SSD and also
backward compatible with SAS 6Gbps, SATA 6Gps and SATA 3Gps HDD/SSD.
Basically, one single SFF-8643 miniSAS connector can support up to 4 disk bays. There
are several miniSAS connectors and 29-pin high profile disk connectors on the
backplanes depends on the product model.
The backplane is implemented with smart fan control feature to support wide variety
of fan modules by auto-calibrating the installed fan modules at system boot. This
feature provides an efficient way to control the thermal heat exhaustion by sensing
the temperature in the enclosure. The fan module speeds up and down upon the
temperature rises and falls in the enclosure.
Along with the smart fan control feature, a system alarming feature is also
implemented to alert users in case Fan module failure and/or system overheat occurs
by illuminating the LED indicator and sounding the buzzer at the same time. Users
can then detect issue and take corresponding actions to resolve the issue according
to the failure type. As soon the issue disappears the alarm stops.

2 Jumper Settings
System indicators and buttons are designed for chassis by connecting 2-wire
cable from front panel (if existed) to the jumpers on the backplane to facilitate
the alarm system accordingly.
The definitions of the Jumpers on the backplane are as below.
Jumper
Name
Function
Details
Model
CN1
Setting Function
1FAN FAIL LED +
2FAN FAIL LED –
3TEMP FAIL LED +
4TEMP FAIL LED -
FAN FAIL LED illuminates
when the fan module
speed is going down below
75% of its expected RPM
TEMP FAIL LED illuminates
when enclosure
temperature is going
higher than the setting of
TEMP ALERT of CN2
IW-RS110-02M
IW-RS208-02M
IW-RS212-02M
CN2
Setting Function
1-2 Short MAX FAN RPM=60%
3-4 Short MAX FAN RPM=80%
1-2 & 3-4 Short MAX FAN RPM=100%
5-6 Open TEMP ALERT 45C
5-6 Short TEMP ALERT 55C
RPM=60% limited the
highest FAN RPM to 60% of
full speed
RPM=80% limited the
highest FAN RPM to 80% of
full speed
RPM=100% allows fan
module to its full speed
TEMP ALERT 45C set alert
triggered at 45 degree in
Celsius.
IW-RS110-02M
IW-RS208-02M
IW-RS212-02M

TEMP ALERT 55C set alert
triggered at 55 degree in
Celsius.
When the temp alert
triggered, the TEMP FAIL
LED of CN1 illuminates and
buzzer sounds in 2
consecutive beeps,
BB—BB—BB--.
JM1
Setting Function
1-3 Short SGPIO_0 Enable
3-5 short SGPIO_0 Disable
2-4 Short SGPIO_1 Enable
4-6 Short SGPIO_1_Disable
To enable/disable SGPIO
function. When SGPIO is
enabled, the Green and
RED LED for disk bay is
controlled by MCU by
sensing the SGPIO signals
sent by RAID/HBA car.
SGPIO_0 is for disk 0 ~ 3
SGPIO_1 is for disk 4 ~ 7
IW-RS110-02M
IW-RS208-02M
IW-RS212-02M
IW-SK35
IW-R400-03N
JM2
Fail_LED_0~3
Fail_LED_0~3 pins are for
use when SGPIO is set to
disabled for disk bay 0 ~ 3
IW-RS110-02M
IW-RS208-02M
IW-RS21202M
JM3
Fail_LED_4~7
Fail_LED_4~7 pins are for
use when SGPIO is set to
disabled for disk bay 4 ~ 7
IW-RS110-02M
IW-RS208-02M
IW-RS212-02M
JM4
Fail_LED_8~11
Fail_LED_8~11 pins are for
use when SGPIO is set to
disabled for disk bay 8 ~ 11
IW-RS110-02M
IW-RS212-02M
JM5
Setting Function
2-4 Short SGPIO_2_Enable
4-6 Short SGPIO_2_Disable
SGPIO_2 is for disk 8 ~ 11
IW-RS110-02M
IW-RS212-02M
JM5
Setting Function
1-2 Short SGPIO_0_Enable
2-3 Short SGPIO_0_Disable
To enable/disable SGPIO
function. When SGPIO is
enabled, the GREEN and
RED LED for disk bays are
controlled by MCU by
IW-SK34
IW-MS04
IW-MS08
IW-MS08-A
IW-PLV Tower
IW-PLG Tower

sensing the SGPIO signals
sent by RAID/HBA card.
SGPIO_0 is for disk 0 ~ 3
SGPIO_1 is for disk 4 ~ 7
IW-SK35
IW-R400-03N
JS1
Setting Function
1Fail_LED_1
2Fail_LED_2
3Fail_LED_3
4Fail_LED_4
Fail_LED pins are for use
for disk bay 1 ~ 4 fail LED
when SGPIO is set to
disabled
IW-SK34
IW-MS04
IW-MS08
IW-MS08-A
IW-PLV Tower
IW-PLG Tower
JS1, JS2
SGPIO Header
The SGPIO header for
connecting to
Motherboard or RAID/HBA
card which equipped with
SGPIO function.
IW-SK35
IW-R400-03N
JS3
Setting Function
1 Fail_LED_1
2 Fail_LED_2
3 Fail_LED_3
4 Fail_LED_4
5 Fail_LED_5
Fail_LED pins are for use
for disk bay 1 ~ 5 fail LED
when SGPIO is set to
disabled
IW-SK35
IW-R400-03N

3Connectors
3.1 29-pin SAS HDD connector
The Backplane has number of 29-pin disk connectors supporting SATA 3G, 6G,
SAS 6G and 12G disk.
Different model has different type and different of 29-pin disk connector
according to design and application.
Model
Number of 29-pin
disk connector
Type
Supported Disk
IW-RS104-02M
4
Horizontal Type
SATA, SAS
IW-RS110-02M
10
Low Profile
SATA, SAS
IW-RS208-02M
8
High Profile
SATA, SAS
IW-RS212-02M
12
High Profile
SATA, SAS
IW-SK34
IW-MS04
IW-MS08
IW-MS08-A
IW-PLV Tower
IW-PLG Tower
4
High Profile
SATA, SAS
IW-SK35
IW-R400-03N
5
High Profile
SATA

3.2 SFF-8643 Mini-SAS connector:
Different model of backplane has different number of miniSAS connector.
Most of backplanes are supporting 12G SAS connection while SK35/ IW-
R400-03N is supporting 6G SATA only.
Since these backplanes has no expander. All the miniSAS connectors or
SATA connectors are directly wired to the 29-pin disk connectors.
Model
Number of miniSAS connector
Note
IW-RS104-02M
1
IW-RS110-02M
3
IW-RS208-02M
2
IW-RS212-02M
3
IW-SK34
IW-MS04
IW-MS08
IW-MS08-A
IW-PLV Tower
IW-PLG Tower
1
IW-SK35
IW-R400-03N
5
SATA connector

3.3 4-Pin power receptacle
Different model of backplane has different number of 4-pin power
connector according to the disk number the backplane supports.
Model
Number of 4-pin Power connector
Note
IW-RS104-02M
2
IW-RS110-02M
4
IW-RS208-02M
4
IW-RS212-02M
6
IW-SK34
IW-MS04
IW-MS08
IW-MS08-A
IW-PLV Tower
IW-PLG Tower
2
IW-SK35
IW-R400-03N
2
This manual suits for next models
17
Table of contents
Other InWin Network Storage Server manuals
Popular Network Storage Server manuals by other brands

HP
HP NetStorage 6000 user guide

Seagate
Seagate U10 ST320423A installation guide

Synology
Synology RackStation RS816 Hardware installation guide

D-Link
D-Link ShareCenter Pro DNS-1200-05 user manual

Avid Technology
Avid Technology VideoRAID ST Setup and user guide

Western Digital
Western Digital My Cloud Home Duo user manual