Integrated Technical Vision DLK640Plus User manual

Stand-alone access control
panel
DLK640Plus
stand-alone access control panel
®

2 Integrated Technical Vision Ltd http://www.itvsystems/com/ua

http://www.itvsystems.com.ua Integrated Technical Vision 3
This manual covers installation, programming and utilization of DLK-640Plus stand-
alone access control unit. Read this manual carefully prior to installing and pro-
gramming the unit.
Design Change Disclaimer
Due to design changes and product improvements, information in this manual is
subject to change without notice. ITV reserves the right to change product design
at any time, which may subsequently affect the contents of this manual.
ITV assumes no responsibility for any errors that may appear in this manual. ITV
will make every reasonable effort to ensure that this Installation/Programming
Manual is up to date and corresponds with the unit you purchase.
Reproduction Disclimer
All rights to this document preserved by Integrated Technical Vision Ltd. Copying,
printing and any other kind of reproduction of the document or its part without
permission of Integrated Technical Vision Ltd is prohibited.
Trademarks
ITV®is a registered trademark of Integrated Technical Vision Ltd.
Training and technical support
Integrated Technical Vision Ltd performs training on the installation, programming
and utilisation of DLK-640Plus stand-alone access control unit. For additional in-
formation about the training and discussing of your particular requirements to the
unit please contact our personnel by the phone numbers below.
For the personnel intended for sales and installation of DLK-640Plus stand-alone
access control unit on permanent basis is recommended to pass the training in
Integrated Technical Vision Ltd.
Technical support for all products of Integrated Technical Vision Ltd can be ob-
tained at working time by the phones:
+380 (0) 44 248 65 88
+380 (0) 44 248 65 89
+380 (0) 44 248 65 90
This support assumes the calls of trained specialists. End users must apply to
their dealers or installers before calling us.
This information is available on our web site www.itvsystems.com.ua

4 Integrated Technical Vision Ltd http://www.itvsystems/com/ua
Contents
Features ....................................................................................6
Operation ...................................................................................7
Mounting ......................................................................................................... 9
Request - to - Exit (RTE) Button ................................................................... 10
Door sensor .................................................................................................. 10
Electric locks and door strikes ...................................................................... 10
Duress Code ................................................................................................ 12
LEDs ............................................................................................................ 12
Control Panel Operation ...........................................................14
Programming ............................................................................14
Factory defaults ............................................................................................ 14
Default times ................................................................................................ 15
Settings displaying ........................................................................................ 15
Hardware reset to factory defaults ................................................................ 15
User code settings’ editing ............................................................................ 20
User code change ........................................................................................ 20
User code review .......................................................................................... 20
[*] button programming mode ....................................................................... 21
APPENDIX 1 ............................................................................ 22
Access Control System ................................................................................ 22
High Degree Security Access Control System .............................................. 24
APPENDIX 2 ............................................................................ 28
Limited Warranty ......................................................................31

http://www.itvsystems.com.ua Integrated Technical Vision 5
Preface
DLK640Plus standalone access control panel is intended for access control sys-
tem creation and/or use in intruder alarm systems. The panel provides one or two
execution units control by means of code entry.
DLK640Plus is characterized by presence of nonvolatile memory, two relays, alarm
output, one engineer code, one chief code and 29 users' codes. Valid code intro-
duction allows you relay control and day/night modes change. The panel supports
such advanced features as request-to-exit, keypad lockout, duress code, two ac-
cess levels. It has three light emitting diodes (LED).
Preface

6 Integrated Technical Vision Ltd http://www.itvsystems/com/ua
Features
–Fully programmable from the built-in keypad
–Three LEDs
–Built-in buzzer
–Utilizes keypad codes from 4 to 10 digits long
–One Master code
–One Engineer code
–29 user codes
– Additional duress code for each user code
–Two access levels
–Two relays
–Alarm output
–Door sensor
–RTE sensor
–Tamper
Specifications
Electrical
–Voltage 10 … 15 V
–Power consumption
–Stand-by 15 mA
–Maximal 70 mA
–Contact Rating
–Relay 5A @ 24 V
–Alarm Output 60 mA @ 24V
–Voltage ripple 500mV@12V
Mechanical
–Weight 200 grams
–Dimensions 156 x 105 x 20 mm
Environmental
–Temperature 0 … +55 C°
–Relative humidity 80% at 25 C° (without condensate)
Features

http://www.itvsystems.com.ua Integrated Technical Vision 7
Operation
General Configuration
The view of DLK-640Plus stand-alone access control panel is shown on Figure 1
1 - LED1,
2 - LED2,
3 - LED3,
4 - built-in keypad,
5 - blank end cover,
6 - control unit PCB,
7 - keypad PCB,
8 - front cover
GN D+12V AL M CM1RTE DC I/O SAB NC1NO1 CM2NC2 NO2
FAC TORY SETTIN G
Keyboard C onnector X2
5
6
7
8
б)
4
a)
123
Operation

8 Integrated Technical Vision Ltd http://www.itvsystems/com/ua
Terminals Layout
Terminals layout on the main board is shown on Figure 2 below
GND+12V ALMCM1RTE DC I/O SAB NC1 NO1CM2 NC2 NO2
FACTORY SETTING
Keyboard Connector X2
Panel baseplate
Keypad PCB
Alarm output
Locking devices
Door sensor
RTE button
+12 V power
Operation

http://www.itvsystems.com.ua Integrated Technical Vision 9
Terminals Assignement
- +12V, GND - +12V power supply connection terminals;
- RTE - request-to-exit button connection terminals;
- DC - door sensor connection terminals;
- I/O - LED 2 external management (red light)
- SAB - tamper connection terminal;
- ALM - transistor alarm output for external unit connection;
- NO2, CM2, NC2 - Relay2 normally open, common and normally closed termi-
nals;
- NO1, CM1, NC1 - Relay1 normally open, common and normally closed termi-
nals.
Mounting
DLK-640Plus stand-alone access control unit is to be mounted indoors at 85%
relative humidity.
DLK640Plus mounting description:
–Release the screw in the bottom of the cover pos a) on Figure 3
–Slightly pull the bottom side of the cover (pos b) on Figure 3) and take it
down
–Disconnect the keypad PCB from the base plate (connector X3)
–Mark the position of the fixing holes on the wall, using back plate as a pat-
tern (pos c) on Figure 3
–Drill fixing holes of the appropriate depth with 6 mm drill
–Pull the wiring through the holes on the back plate and secure the wiring with
supplied screws
–Connect the wires
–Connect the keypad PCB to the baseplate with a screw.
–Fix firmly the front cover
a)
5...10мм
b)
Mounting
holes
Wiring
holes
GND+12V ALMCM1RTE DC I/O SA B NC1 NO1CM2 NC1 NO1
J1
FACTORY
SETTING
Keyboa rd Connec tor X2
c)
Operation

10 Integrated Technical Vision Ltd http://www.itvsystems/com/ua
Request - to - Exit (RTE) Button
Request - to - Exit Button opens a door to exit the premises.
You can also use RTE button for remote door opening - by the guard or secretary.
Direct opening by engaging of the electric lock or door strike will cause the alarm
mode switch.
Depressing of the RTE button is
identical to introducing user code #2.
All settings of the RTE button are to
be programmed for user code #2.
Removal of user code #2 causes
alarm output activation.
If RTE button is pressed more than
8 seconds, alarm output activates.
Door sensor
DLK-640Plus determines door sta-
tus by means of door sensor. If you
do not use door sensor, the unit can-
not detect neither door forcing nor
door left opened for a long time.
The wiring of door sensor and RTE
button is shown on Figure 5. Door
sensor has normally closed con-
tacts, while RTE button must have
normally open contacts.
It is advisable to equip the door with mechanical door closer.
Electric locks and door strikes
The unit has two relays with normally opened and normally closed contacts for
energizing or de-energizing electric locks, door strikes etc.
Relays are activated after valid code introduction. Relays can work in triggering
mode (program the relay time for 0 sec) - in this case relay changes its state on
each valid code entry. Relays
can also be activated for the
programmed time from 1 to
254 sec. You can program
relay activation time for each
code individually.
Relay contact commutation is
5 A @ 24 Volts. Commutation
of the inductive load, electric
lock for instance, causes
high energy electric impulse
induced through relay con-
tacts. If you want to save con-
tacts from damage, protect
them with diode, connected in
reverse to the current supply
voltage of the coil.
RTE
button
Door
sensor
GND ALMCM1RTE DC I/O SAB
Figure 5
Lock 2
Lock 1
ALM CM1
N
DSAB NC1 NO1 CM2 NC2 NO2
+U
пит
Operation
Table of contents
Other Integrated Technical Vision Control Panel manuals