INSTALLATION
Manufactured By:
Integrated Design Ltd, Feltham Point, Browells Lane,
Feltham, Middlesex, TW13 7EQ, United Kingdom
Tel: (+44) (0)208 890 5550
Fax: (+44) (0)208 890 2444
E-mail: info@idl.co.uk
Web: www.fastlane-turnstiles.com

Fastlane® Visitor Card Retrieval System
Confidential
Page 2 of 4 Issue A1 March 2010 © Integrated Design Ltd
Confidential
PRODUCT DESCRIPTION
Production Overview
In order to collect access cards from visitors leaving a building, IDL have created the Visitor Card
Return System. Staff can use a card reader mounted behind the frosted acrylic window. Visitors
however are invited to place their access card in the return slot. The card is drawn in and slowly
passes a secondary card reader which authorises their exit. The cards are then dropped in to a
locked tray where they can be collected by a guard at a later stage
Technical Description
The Card Retrieval System consists of a Motor Card, a drive system and frame. The purpose of
the frame is to guide the cards over the card reader and into the card bin.
Power (12Vdc) is applied to the Motor Card, which in turn powers the Motor/Drive Belt. The
speed of the Motor and the length of time the Motor Drives can both be set on the Motor Card.
Figure 1 - Visitor Card Retrieval Assembly
As cards are pushed into the card slot, they will break an infra-red beam. This is the trigger that
starts the drive belt. The beam is produced by a transmit LED fitted to the frame, and a receive
diode fitted to the Motor Card.
Card Return Motor Card
(see fig.2)
Drive Motor & Pulley
Assembly
Drive Belt
Transmit LED fitted to Frame
(not visible)

Fastlane® Visitor Card Retrieval System
Confidential
Page 3 of 4 Issue A1 March 2010 © Integrated Design Ltd
Confidential
Cards can be collected from the Card Bin at the bottom, via an external, key-locked doorway.
The system is delivered fitted to the Fastlane®Pedestal, and should not need any
adjustment/connections. The Power input will already be connected to the 12Vdc output from the
CAT5 Interface Card.
Figure 2 - Card Return Motor Card
The connections/settings on the Motor Card are as follows:
•+L- will be connected to the Transmit LED. The polarity must always be observed.
•+M- will be connected to the Motor, via a terminal block. The polarity must always be
observed.
•+DC- will be connected to the CAT5 Interface Card. The polarity must always be
observed.
•VR1 adjusts the Motor Speed.
•VR2 adjusts the Motor Time Period.
•D1 is the receive diode, fitted over a hole in the Motor Card. This must always have direct
line-of-sight to the Transmit LED.
•LED1 is a power indicator. If this is not on, then check the power.
VR1 Speed Adjustment VR2 Time Adjustment
D1 Receive Diode LED1 Power Indicator
+L- Transmit LED
Connection
+M- Motor
Connection
+DC- Power Input
(
12Vdc)

Fastlane® Visitor Card Retrieval System
Confidential
Page 4 of 4 Issue A1 March 2010 © Integrated Design Ltd
Confidential
Warranty
Integrated Design Ltd. (The Company) warrants that products manufactured by it are of
merchantable quality, free of any rightful claim of infringement or the like. When used in the
manner intended, will be free of defects in materials or workmanship for a period of twelve (12)
months from the date of sale as shown by a sales invoice or warranty registration card on file with
the Company. The terms of warranty are as per Integrated Design Ltd. Conditions of Sale and will
not apply to any product, which has been modified, or improperly used or repaired after leaving
the Company's control. Any implied warranty of fitness for particular purposes, whether express
or implied, is hereby expressly excluded. These warranty terms may not be modified except in
writing approved and issued by an authorised officer of the Company.
Technical Support
We welcome inquiries and comments regarding all of our products. We trust you will find them
easy to install and reliable in operation. Should you experience any application-related difficulties
however, in the first instance please contact your supplier.
Our direct contact details are:
Fax: UK 0208 890 2444
International +44 208 890 2444
Web: www.fastlane-turnstiles.com
Email: support@idl.co.uk
A technical support form may be downloaded from the IDL web site, please use this form to
provide a description of the reported fault and the corrective action diagnostics information
already attempted.
If a sub-assembly is to be returned for warranty or non-warranty test and repair, please use the
Return to Manufacturer Authorisation system (RMA). Information about this is available on the
web site.
Important Notice
Although every effort has been made to make this manual as accurate as possible, IDL does
NOT accept any liability for errors or omissions. The data contained in this manual supersedes
any other information published on the Product. We further reserve the right to amend or improve
the equipment and/or manual without notice.
Table of contents