inohom Nova Panel V7 User manual

Nova Panel V7
(PAN19V7)
V1.0
TECHNICAL MANUAL
Smart Life Solutions
EN

Content
1: Important Safety Informaton
2: Descrpton and Propertes
3: Techncal Propertes
3.1: Techncal Detals
3.2: Techncal Drawng
4 Installaton
4.1: Before Installaton
4.2: Mechancal and Electrcal Assembly
4.2.1: Return to Factory Settngs
4.2.2: Electrcal Assembly
4.2.3: Mechancal Assembly
5: Communcaton Propertes
6: Multple Nova Panel and Harmony Technology
7: Topology
7.1: Correct Communcaton Topology
7.2: Incorrect Communcaton Topology
8: Screen Layout
9: Commssonng
10: Regulatons
3
4
4
4
5
5
5
6
6
6
9
10
11
12
12
12
13
14
15

3
1: Important Safety Informaton
ELECTRIC SHOCK DANGER!
Do not open the product!
Please read ths manual before usng the devce!
Not followng the recommendatons n ths manual mght lead to danger.
The manufacturer GST ELEKTRONİK LTD ŞTİ cannot be hold responsble
for any loss or damagesarsng from not followng the nstructons n ths user manual.
Devce s no longer under warrant after faults arsng n these cases.
The devce s desgned to control other electronc devces and operates n houses.
Incorrect connecton or usage mght cause fire or electrc shocks.
There mght be voltage on the connecton tps even f the devce s turned off.
The fuse or power source must always be dsabled f the connectons wll be changed.
Do not operate the devce wth wet or most hands to avod electrc shock rsk.
Do not make any changes on ths devce that are not specfied n the user manual.
Do not leave the devce drectly exposed to sunlght or other heat sources. Do
not place the devce near open fire or ntense heat sources such as electrc
Other devces
The manufacturer GST ELEKTRONİK LTD. ŞTİ. cannot be held responsble for
any damages or out-of-warranty f any unsutable connectons other than the
connectons expressed n the connecton manual are made wth other devces.
Ths product s desgned only for ndoors use n a dry envronment.
Do not use the product n wet or damp envronment such as bathtub, snk,
bath and pool.
Devce Cleanng
Heat Sources and Fre
Do not clean the product wth solvent (thnner, gasolne, acd etc.) or
abrasve cleanng products. Avod cleanng wth vapour cleanng tools.
heater.

4
2: Descrpton and Propertes
3: Techncal Propertes
3.1: Techncal Detals
İnohom Nova Panel PAN19V7 has the propertes to manage your house on ts own. The
devce manages all fundamental functons such as ar-condtonng, llumnaton,
curtan-blnds, waterng, securty and energy management. Ths module can control bult-n
thermostat and nput/output. Wth wreless communcaton property, ths module enables
other nohom products to be managed and montored. Bult-n server enables you to
manage your home remotely on moble devces. Wth ntercom property, users can
communcate wth exteror panel, between apartments, and wth securty pont.
Power Consumpton
Supply Voltage
30W (Max)
12VDC
Bult-n 3, External 3+4 Relay (250VAC 5A, 10A)
8 DC Input
W-F, Ethernet, RF 433 Mhz
Lnux OS
2.5mm² screwed electrc termnal
IP 20
0 - 50°C
Max 50°C %65 Ambent Humdty
Max 2000m
Flush Mounted
157mm x 250mm x 40mm
EN55032:2015, EN55024:2011, EN62368-1
Inputs
8 GB
1 GB
1.5 GHz 4 Core
1024 x 600 pxel
7" IPS Capactve
Temperature Sensor (0.5°C Senstvty)
3 Watt
Memory
Sensor
Screen
Resoluton
Processor
Ram
Speaker
Outputs
Communcaton
Operatng System
Connectons
Protecton Class
Operatng Temperature
Heght
Relatve Humdty
Dmenson
Installaton
EMC Standards

157mm
40mm
95mm
191mm
250mm 6mm
5
mm
0 10 20 30 40 50
Scale 1/2
inohom
Dfferent tasks can be assgned to nohom Nova Panel nput and outputs. Functons
assgned to nput and output are provded by nohom authorsed dealers. Ths operaton
s completed by traned techncal personnel n commssonng program.
3.2: Techncal Drawng
4: Installaton
4.1: Before Installaton
Unsutable connectons aganst the manual mght cause health, lfe or materal
damage rsk.
- Do not power on the devce before all the connectons are completed.
- Check the devce user manual to create a secure connecton.
- Do not make any connectons other than the connectons specfied n the scheme.
- Do not connect wth devces that do not comply wth securty standards.
Mount the devce away from metal surfaces or objects to avod any negatve
mpact on the wreless communcaton performance.

6
Z
X
Q
Y
J
4.2: Mechancal and Electrcal Assembly
4.2.1: Return to Factory Settngs
4.2.2: Electrcal Assembly
Wth relay group that can be mounted at the back of the devce, you can make
varous on-off controls over Nova Panel V7.
When energzed:
- pressed and released shorter than 3 seconds = rng tone
- longer than 3 seconds and shorter than 10 seconds = embedded software reset
- longer than 10 seconds and shorter than 30 seconds = nterface software reset
- longer than 30 seconds = database reset
When not energzed:
- longer than 10 seconds = embedded software factory settng reset
X : Motherboard Connector Zone
J : RF Communcaton Module
Y : Reset Button, Temperature Sensor, Mcrophone
Q : Motherboard Protecton Metal Sheet
Z : Speaker

7
C
NC NO
COM
C
C
D
D
E
E
F
F
G
G
H
H
12V
+ -
12V
+ -
V
M
K
L
L
N
N
A
B
CD
E
F
G
H
I
J
SENSOR
RING
SIREN
Sample Connecton 1
Sample Connecton 2
Do not connect llumnaton products to relay outputs wthout nrush property or
external relay accessory outputs of the devce.

8
I
U
I
P
Please make the "P" connecton wth CAT6 cable.
The CAT6 cable should be maxmum 6 metres.
T-BELL:
nohom rng swtch wth camera
P
A
B
J
COM
COM
NO
Q6 Q5 Q4 Q3
COM
NO
COM
NO
NO
NC
B
COM
NO
Q9 Q8 Q7
COM
NO
COM
NO
A
V
LL
N
N
M
Optonal Relay Optons
(A) Product Code PAN19-RL30
Product Name: NOVA Panel 3 Channel Relay Module (5A 250VAC)
(B) Product Code PAN19-RL40
Product Name: NOVA Panel 4 Channel Standard Relay Module (10A 250VAC)
(B) Product Code PAN19-RL42
Product Name: NOVA Panel 4 Channel Inrush Relay Module (10A 250VAC Inrush 40A)
L : Phase
N : Neutral
V : Motor-operated valve
K : Comb boler connecton
M : Curtan, Blnder Shutter
Q : Dgtal Output Connecton
COM : Common Contact Pont
+,- : Postve, Negatve Poles
U

Flush mounted body measurement : 150mm x 240mm x 73mm
Screw sze : Ø2.8 x 25mm
J
9
communcaton wth RF communcaton module.
Ths s used for data transmsson n
automaton projects that need wreless
The flush mounted box should be placed 150 cm above the ground. Make sure that the
apparatus s parallelly mounted to the ground. For mountng, please use mountng
screws n the product box. Please use the correspondng holes to mount panel body wth
mountng screws. Then, complete the mountng by usng the metal magnet laths.
4.2.3: Mechancal Assembly

SMART TOUCH
SWITCH 2
SMART TOUCH
SWITCH 4
WEB
RF 433 Mhz
inohom
CCM176X
16A
COM1
COM2
COM3
COM4
COM5
COM7
COM6
Q1
Q0
Q6
Q7
I 0
I 1
I 2
I 3
I 4
I 5
I 6
I 7
I 15
I 14
I 13
I 12
I 11
I 10
I 9
I 8
Q15
Q14
Q13
Q12
Q11
Q10
Q9
Q8
12V
+ -
Q5
Q4
Q3
Q2
COM0
10A
inohom
RL 1720
NOVA PANEL
MOBIL
CCM 176X
inohom inohom
SWITCH
10
inohom
Other devces
ntegrated va IP
Camera, Intercom, EIO
5: Communcaton Propertes
The product can be optonally used wth or wthout relay.
İnohom IP Gateway devces (Nova Panel/Home Manager) enable managng
other devces ntegrated to the automaton va the nternet by enablng the system
to communcate on IP layer.
The devces use nohom communcaton protocol. İnohom Nova Panel can wrelessly
communcate wth other nohom products and can learn and swtch output state
values of other products.
This manual suits for next models
1
Table of contents
Other inohom Home Automation manuals