inDESIGN iD-HP Series User manual


iD-HP SERIES SUBWOOFERS: INSTALLATION & OPERATION MANUAL
PAGE 2
Thank you for choosing inDESIGN HP series loudspeaker products
for your application. Please spare a little time to read the
contents of this manual, so that you can obtain the best possible
performance from these products.
The inDESIGN iD-HP loudspeaker series is a compact, high output
design suitable for mobile and permanent sound installations.
Attention to detail during development of these products
provides high SPL output with a smooth neutral sonic character,
multiple installation options at a very competitive price.
INTRODUCTIONCONTENTS
Electrical and Safety Warnings
THESE SERVICE INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY.
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING
OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS
UNLESS YOU ARE QUALIFIED TO DO SO.
CAUTION
The lightening ash with arrowhead
symbol, with an equilateral triangle,
is intended to alert the user to the
presence of un-insulated
“dangerous voltage” within the products
enclosure that may be of sufcient
magnitude to constitute a risk of electric
shock to persons.
WARNING: TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING: TO REDUCE THE RISK OF FIRE OR
ELECTRICAL SHOCK, DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR MOISTURE.
The exclamation point within an
equilateral triangle is intended to
alert the user to the presence of
important operating and maintenance
(servicing) instructions in the literature
accompanying the appliance.
INTRODUCTION 2
IMPORTANT SAFETY
INSTRUCTIONS 3
FEATURES 4
CONNECTIONS 5
SPEAKER MOUNTING 5
TECHNICAL DRAWINGS 6-7
SPECIFICATIONS 8
WARRANTY INFO 11-12

iD-HP SERIES SUBWOOFERS: INSTALLATION & OPERATION MANUAL PAGE 3
IMPORTANT SAFETY INSTRUCTIONS
WARNING: There are no user serviceable parts inside. Refer all servicing to qualied service personnel.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. To prevent injury please refer to these instructions for electrical and safety information before installing
or operating the apparatus.
6. No naked ame sources such as lighted candles should be placed on the apparatus.
7. Operation of this apparatus is recommended for moderate climates only.
8. This apparatus must not be exposed to dripping or splashing liquid.
No object lled with liquid, such as a vase, should be placed on the apparatus.
9. Clean only with a dry cloth.
10. Do not block any of the ventilation openings. Install in accordance with the manufacturer’s instructions.
11. Do not install near any heat sources such as radiators, heaters, stoves, or other apparatuses
(including ampliers) that produce heat.
12. Unplug this apparatus during lightening storms or when not in use for long periods of time.
13. Protective Earthing Terminal:
The apparatus should be connected to a mains socket outlet with a protective earthing connection.
14. The mains plug/appliance coupler is used as a disconnect device, the disconnect device shall remain
readily operable.
15. When not in use and during transportation, please take care of the power cord set, for example, tie up
the power cord set with a cable tie/something similar. It should be kept away from sharp edges and
the like that can cause abrasion of the power cord set. When put into use again, check that the power
cord set is not damaged. If any damage is found, have the unit checked by a qualied service person
to replace the power cord set specied by the manufacturer.
16. The terminals marked with symbol of “ “ may be of sufcient magnitude to constitute a risk of
electric shock. The external wiring connected to the terminals requires installation by a qualied service
person or the use of ready-made leads or cords.
17. Only use attachments/accessories specied by the manufacturer.
18. Check speaker line load prior to connecting to amplier using an impedance meter.
19. Refer all servicing to qualied service personnel. Servicing is required if the apparatus has been
damaged in any way, such as power-supply cord or plug breakage, damage due to liquid or objects
falling onto the apparatus, exposure to rain or moisture, or if the apparatus does not operate normally,
or has been dropped.
20. Correct Disposal of this Product:
This marking indicates that this product should not be disposed of with other household wastes. To
prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle
it responsibly to promote the sustainable reuse of material resources. To return your used device, please
use the return and collection systems or contact the retailer where the product was purchased. They
can take this product for environmental-safe recycling.

iD-HP SERIES SUBWOOFERS: INSTALLATION & OPERATION MANUAL
PAGE 4
FEATURES
• Neutral sonic quality: Carefully designed and matched loudspeaker drive units are used to give you
exceptional performance and many years of reliable, trouble free operation.
• High quality loudspeaker components are used throughout the range. Low frequency drivers are
specied for high sensitivity and durability, while high frequency drivers are selected for consistent and
reliable performance.
• High frequency protection system: Thermal overload circuits operate on all two-way products to
prevent damage to the HF drive units from both transient peaks and long term heating effects.
• Professional appearance: iD-HP series enclosures suitable for live sound and DJ applications as well as
permanent installations.
• Wide dispersion: iD-HP series cabinets are designed to give wide and even dispersion patterns in order
to maximise sound coverage over a given area from a single loudspeaker. Each two-way product
features a rotatable HF horn are allowing horizontal or vertical mounting/operation.
• Monitor Mode: A wedge angle is built into each 2 way product, allowing the loudspeakers to be
placed on their sides to perform monitor duties. Don’t forget to rotate the horn.
• Near or Far? Each two-way iD-HP cabinet features a NEAR/FAR switch, allowing you to decide the best
HF setting for the situation at hand.
• Solid construction: All iD-HP series cabinets are built from high grade, multilayer plywood and are
nished in a durable matt textured paint.
• Pole mount and tripod stand use is facilitated by the provision of integral 35mm pole mount ttings in
both two-way and low extension products.
• NL4MP connectors are tted to all iD-HP series cabinets, enabling simple and easy hook-up as well
providing loop-in/loop-out facilities to additional enclosures.

iD-HP SERIES SUBWOOFERS: INSTALLATION & OPERATION MANUAL PAGE 5
CONNECTIONS
Located on the rear panel of each loudspeaker you’ll nd 2x NL4 speakon connection points. Use either of
the two connection points to connect the loudspeaker to an amplier.
Note: You may use the second NL4 connection to link to another loudspeaker. Take note of your
impedance load as to not overload the connected amplier.
Speakon Wiring
The loudspeaker connectors are wired pin 1+ and pin 1-
2 + Not used
2 - Not used
Speaker Cable
The gauge of speaker cable should be the heaviest gauge where practical to reduce transmission power
loss from the connected amplier.
4.00 mm2 cable is a popular gauge for low extension products. A gauge smaller than 2.5 mm2 should be
avoided when wiring the iD-HP15SUB and iD-HP18SUB products.
SPEAKER MOUNTING
The iD-HP15SUB and iD-HP18SUB are a ground-based
design. They were not designed to be own at height.
Cabinet Stacking
Users may stack multiple sub enclosures together.
Note: Users must ensure the cabinets are strapped
and/or secured correctly to prevent the stack from
toppling over.
Top Hat Mounting
Each sub model comes equipped with a 35mm top
hat mount installed into the top of the cabinet. Use
a sub-satellite mounting pole to couple a mid/hi box
with your sub.

iD-HP SERIES SUBWOOFERS: INSTALLATION & OPERATION MANUAL
PAGE 6
PRODUCT TECHNICAL DRAWINGS
iD-HP15SUB

iD-HP SERIES SUBWOOFERS: INSTALLATION & OPERATION MANUAL PAGE 7
iD-HP18SUB

iD-HP SERIES SUBWOOFERS: INSTALLATION & OPERATION MANUAL
PAGE 8
SPECIFICATIONS
iD-HP15SUB / iD-HP15SUB W iD-HP18SUB / iD-HP18SUB W
Design Front-loaded bass reex
Frequency response -3dB 40Hz - 300Hz 45Hz - 300Hz
LF driver woofer 1x 15” (385mm)
4” voice coil
1x 18” (460mm)
4” voice coil
Rated power watts 600W RMS,
2400W peak
Sensitivity 99dB 1W/1m 100dB 1W/1m
Max SPL 126dB continuous,
132dB peak
128dB continuous,
134dB peak
Impedance 8Ω nominal
Input connectors 2x NL4 Speakon
Cabinet construction Plywood
Top hat Yes (35mm)
Eye bolt mounting No.
Ground stack only.
Black colour Yes
White colour Yes
Shipping dimensions 670 x 550 x 605 mm 880 x 660 x 655 mm
Shipping weight 34kg 38kg
* Disclaimer: Instructions and specications are correct at time of printing.
Information within may be subject to change without notice.

iD-HP SERIES SUBWOOFERS: INSTALLATION & OPERATION MANUAL PAGE 9
NOTES

iD-HP SERIES SUBWOOFERS: INSTALLATION & OPERATION MANUAL
PAGE 10
NOTES
Other manuals for iD-HP Series
1
This manual suits for next models
4
Table of contents