SAFETY 1 INPUT
Mechanical safety edge (N.C./N.O.)
Resistive safety edge 8.2kΩ / 10kΩMechanical safety edge (N.C./N.O.)
SAFETY 2 INPUT
Mechanical safety edge (N.C./N.O.)
Mechanical safety edge (N.C./N.O.) Resistive safety edge
STEP 1
OPTION 1
Refer to Example 1
Table 1
OPTION 2 OPTION 3 OPTION 4
WARNING: If you use mechanical safety edges, both safety edges must be configured the same with either a normally
open contact, or a normally closed contact.
The iGAZE®RE transceiver system is intended as a safety device for automated gates and rolling doors. The system is
comprised of 1 fixed device (RC00900) with 2 output relays, which is connected to the operator, and up to 8 movable
devices (TC00900) for each relay. The system TCOO900 will accept safety edges with the following outputs: Mechani-
cal edges with a N.O. or N.C. output, 10kΩ or 8.2kΩ Resistive edges. The fixed device also has 2 controls to perform
an “Auto-test” for operators that have this feature. The transmission signal is bi-directional and utilizes the frequencies
902-928MHz. Maximum range between the movable and fixed devices is 60 feet.
TCOO900 is suitable for outdoor use. RCOO900 is suitable for indoor use only (“indoor” means inside the
operator box. ) The installation of the system must be carried out by a qualified installer.
CONNECT THE SAFETY EDGE TO THE SAFETY EDGE MOVABLE DEVICE (TCOO900)
It is possible to connect multiple safety edge technologies into each safety edge movable device within certain
conditions as shown in Table 1.
STEP 2
SET THE DIP SWITCHES OF THE
TCOO900 TO CORRESPOND TO
THE EDGE CONFIGURATION YOU
HAVE CHOSEN ACCORDING TO
THE CONDITIONS OF TABLE 1 AND
PER THE FOLLOWING EXAMPLES:
A
DESCRIPTION
B
CONFIGURATION AND ELECTRICAL CONNECTIONS
Resistive edge 2
EXAMPLE 1 - Both safety edges are 8.2kΩ or 10kΩ resistive (MOST COMMON INSTALLATION)
N° DIP Function
1 Mechanical (OFF) or resistive (ON) edge 1.
2 Mechanical (OFF) or resistive (ON) edge 2.
3 Low Power (see Section E on page 11).
4
5
6 Mechanical edge with N.C. contact (OFF) or
Mechanical edge with N.O. contact (ON)
Frequency channel selection (see page 6)
TCOO900
(All switches in example
above are set to OFF)
DIP
ON
OFF
1 2 3 4 5 6
DIP1 ON:
resistive safety edge 8.2kΩ/10kΩ 1
resistive safety edge 8.2kΩ/10kΩ 2
If you want to connect a resistive edge on
the input Safety1 (8.2kΩ/10kΩ resisitor), you
must set dip switch 1 to «ON».
(8.2kΩ/10kΩ resistor ), you
must set dip switch 2 to «ON».
DIP2 ON:
If you want to connect a resistive edge on
the input Safety2
DIP6: Not Used
Led and
programming /
test key 2
Dip switch
Led and
programming /
test key 1
Resistive edge 1 8.2kΩ(N.C.)
Resistive edge 2 8.2kΩ
/10kΩ
/10kΩ
(N.C.)
F
Frequency
Low Power
Safety2 Type
Safety1 Type
Safety2
Safety1 Resistive edge 1
1 2 3 4 5 6
configuration
Prog/Test2Prog/Test1
DIP
ON
OFF
8.2kΩ / 10kΩ
Resistive safety edge 8.2kΩ/ 10kΩ
Resistive safety edge 8.2kΩ/ 10kΩ