IBM 9006-22C Instruction Manual

Power Systems
Installing and conguring the IBM Power
System LC922 (9006-22P)
IBM

Note
Before using this information and the product it supports, read the information in “Safety notices” on
page v, “Notices” on page 123, the IBM Systems Safety Notices manual, G229-9054, and the IBM
Environmental Notices and User Guide, Z125–5823.
This edition applies to IBM® Power Systems servers that contain the POWER9™ processor and to all associated models.
© Copyright International Business Machines Corporation 2017, 2019.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with
IBM Corp.

Contents
Safety notices........................................................................................................v
Installing and conguring the system.....................................................................1
Installing the system....................................................................................................................................1
Prerequisites for installing the rack-mounted system.......................................................................... 1
Completing inventory for your system................................................................................................... 1
Determining and marking the location in the rack for the system........................................................2
Attaching the rails to the rack and to the system.................................................................................. 4
Installing the system into the rack and connecting and routing power cables.................................... 7
Completing server setup........................................................................................................................ 8
Installing drives............................................................................................................................................9
Drive installation options for the 9006-22P system............................................................................. 9
Installing a front drive..........................................................................................................................13
Installing a rear drive........................................................................................................................... 19
Installing a drive on module.................................................................................................................24
Installing memory......................................................................................................................................26
Placement rules for memory in the 9006-12P or 9006-22P system.................................................26
Installing memory in the 9006-22P system........................................................................................28
Installing a PCIe adapter...........................................................................................................................30
PCIe adapter placement rules and slot priorities for the 9006-22P system..................................... 30
PCIe adapters by FC for the 9006-22P............................................................................................... 35
Installing a PCIe adapter in the 9006-22P system.............................................................................89
Common procedures for servicing or installing features in the 5104-22C,
9006-22C, or 9006-22P system........................................................................ 99
Before you begin servicing........................................................................................................................ 99
Identifying the 5104-22C, 9006-12P, 9006-22C, or 9006-22P system that contains the part to
replace................................................................................................................................................ 102
LEDs on the 5104-22C, 9006-22C, or 9006-22P system................................................................ 102
Identifying the 5104-22C, 9006-12P, 9006-22C, or 9006-22P that needs servicing................... 104
Preparing the system to remove and replace internal parts.................................................................. 105
Preparing the system for operation.........................................................................................................107
Starting and stopping the system........................................................................................................... 108
Starting the 5104-22C, 9006-12P, 9006-22C, or 9006-22P system .............................................108
Stopping the 5104-22C, 9006-12P, 9006-22C, or 9006-22P system............................................110
Drive commands for 5104-22C, 9006-12P, 9006-22C, or 9006-22P..................................................111
arcconf commands.............................................................................................................................111
StorCLI commands.............................................................................................................................111
sas3ircu commands...........................................................................................................................113
NVMe commands............................................................................................................................... 113
Sensor readings GUI display................................................................................................................... 114
Removing and replacing covers.............................................................................................................. 115
Removing the service access cover...................................................................................................115
Installing the service access cover....................................................................................................116
Service and operating positions..............................................................................................................117
Placing an 5104-22C, 9006-22C, or 9006-22P system into the service position...........................117
Placing an 5104-22C, 9006-22C, or 9006-22P system into the operating position.......................118
Power cords for the 5104-22C, 9006-22C, or 9006-22P system......................................................... 119
Disconnecting the power cords......................................................................................................... 119
Connecting the power cords..............................................................................................................120
iii

Notices..............................................................................................................123
Accessibility features for IBM Power Systems servers.......................................................................... 124
Privacy policy considerations ................................................................................................................. 125
Trademarks.............................................................................................................................................. 125
Electronic emission notices.....................................................................................................................126
Class A Notices...................................................................................................................................126
Class B Notices...................................................................................................................................129
Terms and conditions.............................................................................................................................. 132
iv

Safety notices
Safety notices may be printed throughout this guide:
•DANGER notices call attention to a situation that is potentially lethal or extremely hazardous to people.
•CAUTION notices call attention to a situation that is potentially hazardous to people because of some
existing condition.
•Attention notices call attention to the possibility of damage to a program, device, system, or data.
World Trade safety information
Several countries require the safety information contained in product publications to be presented in their
national languages. If this requirement applies to your country, safety information documentation is
included in the publications package (such as in printed documentation, on DVD, or as part of the product)
shipped with the product. The documentation contains the safety information in your national language
with references to the U.S. English source. Before using a U.S. English publication to install, operate, or
service this product, you must rst become familiar with the related safety information documentation.
You should also refer to the safety information documentation any time you do not clearly understand any
safety information in the U.S. English publications.
Replacement or additional copies of safety information documentation can be obtained by calling the IBM
Hotline at 1-800-300-8751.
German safety information
Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der
Bildschirmarbeitsverordnung geeignet.
Laser safety information
IBM servers can use I/O cards or features that are ber-optic based and that utilize lasers or LEDs.
Laser compliance
IBM servers may be installed inside or outside of an IT equipment rack.
DANGER: When working on or around the system, observe the following precautions:
Electrical voltage and current from power, telephone, and communication cables are hazardous. To
avoid a shock hazard:
• If IBM supplied the power cord(s), connect power to this unit only with the IBM provided power
cord. Do not use the IBM provided power cord for any other product.
• Do not open or service any power supply assembly.
• Do not connect or disconnect any cables or perform installation, maintenance, or reconguration
of this product during an electrical storm.
• The product might be equipped with multiple power cords. To remove all hazardous voltages,
disconnect all power cords.
– For AC power, disconnect all power cords from their AC power source.
– For racks with a DC power distribution panel (PDP), disconnect the customer’s DC power
source to the PDP.
• When connecting power to the product ensure all power cables are properly connected.
– For racks with AC power, connect all power cords to a properly wired and grounded electrical
outlet. Ensure that the outlet supplies proper voltage and phase rotation according to the
system rating plate.
© Copyright IBM Corp. 2017, 2019 v

– For racks with a DC power distribution panel (PDP), connect the customer’s DC power source
to the PDP. Ensure that the proper polarity is used when attaching the DC power and DC power
return wiring.
• Connect any equipment that will be attached to this product to properly wired outlets.
• When possible, use one hand only to connect or disconnect signal cables.
• Never turn on any equipment when there is evidence of re, water, or structural damage.
• Do not attempt to switch on power to the machine until all possible unsafe conditions are
corrected.
• Assume that an electrical safety hazard is present. Perform all continuity, grounding, and power
checks specied during the subsystem installation procedures to ensure that the machine meets
safety requirements.
• Do not continue with the inspection if any unsafe conditions are present.
• Before you open the device covers, unless instructed otherwise in the installation and
conguration procedures: Disconnect the attached AC power cords, turn off the applicable circuit
breakers located in the rack power distribution panel (PDP), and disconnect any
telecommunications systems, networks, and modems.
DANGER:
• Connect and disconnect cables as described in the following procedures when installing,
moving, or opening covers on this product or attached devices.
To Disconnect:
1. Turn off everything (unless instructed otherwise).
2. For AC power, remove the power cords from the outlets.
3. For racks with a DC power distribution panel (PDP), turn off the circuit breakers located in the
PDP and remove the power from the Customer's DC power source.
4. Remove the signal cables from the connectors.
5. Remove all cables from the devices.
To Connect:
1. Turn off everything (unless instructed otherwise).
2. Attach all cables to the devices.
3. Attach the signal cables to the connectors.
4. For AC power, attach the power cords to the outlets.
5. For racks with a DC power distribution panel (PDP), restore the power from the Customer's
DC power source and turn on the circuit breakers located in the PDP.
6. Turn on the devices.
Sharp edges, corners and joints may be present in and around the system. Use care when
handling equipment to avoid cuts, scrapes and pinching. (D005)
(R001 part 1 of 2):
DANGER: Observe the following precautions when working on or around your IT rack system:
• Heavy equipment–personal injury or equipment damage might result if mishandled.
• Always lower the leveling pads on the rack cabinet.
• Always install stabilizer brackets on the rack cabinet unless the earthquake option is to be
installed.
• To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest
devices in the bottom of the rack cabinet. Always install servers and optional devices starting
from the bottom of the rack cabinet.
vi Power Systems: Installing and conguring the IBM Power System LC922 (9006-22P)

• Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top
of rack-mounted devices. In addition, do not lean on rack mounted devices and do not use them
to stabilize your body position (for example, when working from a ladder).
• Each rack cabinet might have more than one power cord.
– For AC powered racks, be sure to disconnect all power cords in the rack cabinet when directed
to disconnect power during servicing.
– For racks with a DC power distribution panel (PDP), turn off the circuit breaker that controls
the power to the system unit(s), or disconnect the customer’s DC power source, when directed
to disconnect power during servicing.
• Connect all devices installed in a rack cabinet to power devices installed in the same rack
cabinet. Do not plug a power cord from a device installed in one rack cabinet into a power device
installed in a different rack cabinet.
• An electrical outlet that is not correctly wired could place hazardous voltage on the metal parts
of the system or the devices that attach to the system. It is the responsibility of the customer to
ensure that the outlet is correctly wired and grounded to prevent an electrical shock. (R001 part
1 of 2)
(R001 part 2 of 2):
CAUTION:
• Do not install a unit in a rack where the internal rack ambient temperatures will exceed the
manufacturer's recommended ambient temperature for all your rack-mounted devices.
• Do not install a unit in a rack where the air flow is compromised. Ensure that air flow is not
blocked or reduced on any side, front, or back of a unit used for air flow through the unit.
• Consideration should be given to the connection of the equipment to the supply circuit so that
overloading of the circuits does not compromise the supply wiring or overcurrent protection. To
provide the correct power connection to a rack, refer to the rating labels located on the
equipment in the rack to determine the total power requirement of the supply circuit.
•(For sliding drawers.) Do not pull out or install any drawer or feature if the rack stabilizer brackets
are not attached to the rack or if the rack is not bolted to the floor. Do not pull out more than one
drawer at a time. The rack might become unstable if you pull out more than one drawer at a time.
•(For xed drawers.) This drawer is a xed drawer and must not be moved for servicing unless
specied by the manufacturer. Attempting to move the drawer partially or completely out of the
rack might cause the rack to become unstable or cause the drawer to fall out of the rack. (R001
part 2 of 2)
CAUTION: Removing components from the upper positions in the rack cabinet improves rack
stability during relocation. Follow these general guidelines whenever you relocate a populated rack
cabinet within a room or building.
• Reduce the weight of the rack cabinet by removing equipment starting at the top of the rack
cabinet. When possible, restore the rack cabinet to the conguration of the rack cabinet as you
received it. If this conguration is not known, you must observe the following precautions:
Safety notices vii

– Remove all devices in the 32U position (compliance ID RACK-001 or 22U (compliance ID
RR001) and above.
– Ensure that the heaviest devices are installed in the bottom of the rack cabinet.
– Ensure that there are little-to-no empty U-levels between devices installed in the rack cabinet
below the 32U (compliance ID RACK-001 or 22U (compliance ID RR001) level, unless the
received conguration specically allowed it.
• If the rack cabinet you are relocating is part of a suite of rack cabinets, detach the rack cabinet
from the suite.
• If the rack cabinet you are relocating was supplied with removable outriggers they must be
reinstalled before the cabinet is relocated.
• Inspect the route that you plan to take to eliminate potential hazards.
• Verify that the route that you choose can support the weight of the loaded rack cabinet. Refer to
the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet.
• Verify that all door openings are at least 760 x 230 mm (30 x 80 in.).
• Ensure that all devices, shelves, drawers, doors, and cables are secure.
• Ensure that the four leveling pads are raised to their highest position.
• Ensure that there is no stabilizer bracket installed on the rack cabinet during movement.
• Do not use a ramp inclined at more than 10 degrees.
• When the rack cabinet is in the new location, complete the following steps:
– Lower the four leveling pads.
– Install stabilizer brackets on the rack cabinet or in an earthquake environment bolt the rack to
the floor.
– If you removed any devices from the rack cabinet, repopulate the rack cabinet from the lowest
position to the highest position.
• If a long-distance relocation is required, restore the rack cabinet to the conguration of the rack
cabinet as you received it. Pack the rack cabinet in the original packaging material, or equivalent.
Also lower the leveling pads to raise the casters off of the pallet and bolt the rack cabinet to the
pallet.
(R002)
(L001)
DANGER: Hazardous voltage, current, or energy levels are present inside any component that has
this label attached. Do not open any cover or barrier that contains this label. (L001)
(L002)
viii Power Systems: Installing and conguring the IBM Power System LC922 (9006-22P)

DANGER: Rack-mounted devices are not to be used as shelves or work spaces. Do not place
objects on top of rack-mounted devices. In addition, do not lean on rack-mounted devices and do
not use them to stabilize your body position (for example, when working from a ladder). (L002)
(L003)
or
or
or
or
Safety notices ix

DANGER: Multiple power cords. The product might be equipped with multiple AC power cords or
multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and
power cables. (L003)
(L007)
CAUTION: A hot surface nearby. (L007)
(L008)
CAUTION: Hazardous moving parts nearby. (L008)
All lasers are certied in the U.S. to conform to the requirements of DHHS 21 CFR Subchapter J for class 1
laser products. Outside the U.S., they are certied to be in compliance with IEC 60825 as a class 1 laser
product. Consult the label on each part for laser certication numbers and approval information.
CAUTION: This product might contain one or more of the following devices: CD-ROM drive, DVD-
ROM drive, DVD-RAM drive, or laser module, which are Class 1 laser products. Note the following
information:
• Do not remove the covers. Removing the covers of the laser product could result in exposure to
hazardous laser radiation. There are no serviceable parts inside the device.
• Use of the controls or adjustments or performance of procedures other than those specied
herein might result in hazardous radiation exposure.
(C026)
x Power Systems: Installing and conguring the IBM Power System LC922 (9006-22P)
This manual suits for next models
2
Table of contents
Other IBM Power Supply manuals

IBM
IBM 5786 Use and care manual

IBM
IBM Power System AC922 User manual

IBM
IBM Power System IC922 User guide

IBM
IBM 9008-22L User manual

IBM
IBM Power System AC922 User manual

IBM
IBM Power Systems EMX0 PCIe Gen3 Instruction Manual

IBM
IBM 170 Servers User manual

IBM
IBM 9223-22H User manual

IBM
IBM GX7000 Series Guide

IBM
IBM Power System IC922 User manual