IBA ibaFOB-4i-S User manual

3.1
en
Version 3.2

Page 2 Manual ibaFOB-4i-S / -io-S
ibaFOB-4i-S / -io-S -Manual
Issued by
iba AG
Koenigswarterstr. 44
90762 Fuerth, Germany
Tel.: + 49 (0)911 9 72 82-0
Sales -27
Support -14
R&D -13
FAX -33
Email: [email protected]
Web: www.iba-ag.com
Unless explicitly stated to the contrary, it is not permitted to pass on or copy this docu-
ment, nor to make use of its contents or disclose its contents. Any violation is treated as
an act liable for damages.
iba AG 2009 all rights reserved.
ibaFOB-4i-S / -io-S - Manual V 3.2 en / ibaFOB A2 / A8
We have checked that the contents of this manual match the hardware and software de-
scribed here. However, deviations cannot be fully ruled out, so that we cannot assume
any warranty should any deviations actually exist. This manual is regularly updated. Nec-
essary revisions are included in future editions, or can be downloaded from the Internet.
The latest version is always available for downloading at:
http://www.iba-ag.com
We would welcome any suggestions for improvements which you may have.
Version Date Revision Chapter / pages Author Version HW/FW
V 3.2 03/05/12 Chapter Accessories removed st
iba AG 2012

ibaFOB-4i-S / -io-S Manual Page 3
Contents
This manual 4
1Introduction 5
2Scope of Delivery 7
3Safety Information 7
4Installation / Uninstallation 8
4.1 Preparation.................................................................................... 8
4.2 Installing the Card ......................................................................... 9
4.3 Removing the Card ....................................................................... 9
5System Requirements 10
5.1 Hardware..................................................................................... 10
5.2 Software ...................................................................................... 10
6Driver installation 11
6.1 Windows XP .................................................................................11
7System Integration 13
7.1 Topologies ................................................................................... 13
8Device description 15
8.1 Device properties ........................................................................ 15
8.2 Views, Displays and Connectors ................................................. 16
8.2.1. ibaFOB-io-S ...........................................................................................16
8.2.2. ibaFOB-4i-S ...........................................................................................16
8.3 Front Side Elements.................................................................... 17
8.3.1. LEDs ......................................................................................................17
8.3.2. 7-Segment Display.................................................................................17
8.3.3. Fiber Optic Interface of ibaFOB-io-S......................................................17
8.3.4. Fiber Optic Interfaces of ibaFOB-4i-S....................................................17
8.3.5. Fiber Optic Interfaces of ibaFOB-4o (optional) ......................................18
8.3.6. Fiber Optic Interfaces of ibaFOB-OF-Link (optional)..............................18
8.3.7. Synchronisation Output Module ibaFOB-Sync-Out (optional)................19
8.3.8. Synchronisation Input Module ibaFOB-Sync-In (optional) .....................19
9Configuration and Engineering 20
9.1 Configuration and Diagnostics with ibaPDA-V6........................... 20
9.1.1. Configuration of the Card.......................................................................20
9.1.2. Module and Signal Configuration...........................................................21
9.1.3. Diagnosis ...............................................................................................23
10 Synchronization of Several Boards 24
11 Technical Data 25
12 Support 26
iba AG 2012

Page 4 Manual ibaFOB-4i-S / -io-S
This manual
This compact manual provides the information for installation and handling of the devices
ibaFOB-4i-S / -io-S, ibaFOB-io-S, ibaFOB-4o, ibaFOB-OF-Link and ibaFOB-Sync.
For further information concerning the system integration and software configuration
please refer to the corresponding engineering manuals and / or software documentation
of our software products used in conjunction with this device.
You can find the latest issue of this manual always on our website
http://www.iba-g.com in the download area.
This manual uses several symbols which essentially have the following meanings:
Important hint or warning in order to avoid hazard against material or life.
A useful tip or clue to make your work easier.
This draws your attention to special features, such as exceptions to rules, etc.
A reference to additional documentation or more in-depth literature.
iba training courses
Hint for training courses by iba concerning related products or subjects
Copyright notice
Windows is a registered trademark of Microsoft Corporation.
Other product or company names mentioned in this manual may be brand names or regis-
tered trademarks of the corresponding owner.
iba AG 2012

ibaFOB-4i-S / -io-S Manual Page 5
1Introduction
The boards ibaFOB-io-PCI, ibaFOB-io-S, ibaFOB-4i-PCI, ibaFOB-4i-S, ibaFOB-4o and
ibaFOB-OF-Link are fiber optic communication cards which are used to connect a stan-
dard PC to the iba peripheral devices such as ibaPADUs, ibaNet750-BM devices and
ibaLink signal modules (SM).
As far as the following text does not refer to a particular card, the boards are referred to
as ibaFOB boards.
The unique peripheral I/O concept based on the ibaFOB boards, features characteristics
otherwise unknown on standardized field buses such as:
Full deterministic transmission profiles for all fiber optic buses and connected devices
(1ms).
Internal and/or external synchronization on the bus, even for more than one bus with
programmable cycle times between 1.0 and 9.9 ms in steps of 100 μs.
Deviation less than 2 μs between several busses (external synchronization)
The iba fiber optic transmission standard integrates not only A/D converters (ibaPADU)
but a huge variety of PLC interfaces and hence allows the realization of heterogene-
ous measuring and I/O topologies. The following devices can be connected:
ibaFOB x/4 (ISA)
ibaFOB x/4-F (ISA) with ibaFOB-OF-Link
ibaFOB 2/2 I/O (ISA)
ibaLink-SM-64-io (Siemens Simatic S5 115U, 135U 155U; MMC216 all types)
ibaLink-SM-128V-i-2o (VME32 & VME64 rack)
ibaNet750-BM (Wago IO system 750)
ibaBM-FOX-i-3o (FO-splitter and repeater)
ibaPADU-8, ibaPADU-8-ICP, ibaPADU-8-M, ibaPDAU-8-S, ibaPADU-16, ibaPADU-
32-T, ibaPADU-32-R and ibaPADU-8-O (A/D & D/A -converter)
ibaBM-SLM (Simolink Monitor for Siemens Motion Link Bus)
ibaBM-DDCSM (Monitor for ABB DDCS+ Drivebus)
Adjustable bus timing (ring topology in combination with ibaLogic only!)
Easy handling without the termination problems of copper based systems
The integration in hazardous areas is no problem in terms of EMI due to the fiber
optic communication concept.
One source can be accessed by multiple clients at the same time by just multiply-
ing the optical fibers (ibaFOx-3 and ibaFOB-OF-Link splitting devices) – so I/O pe-
ripherals may be used for process control and measuring at the same time. This
also makes redundant structures easy.
100% compatibility to its predecessors based on the ISA bus
iba AG 2012

Page 6 Manual ibaFOB-4i-S / -io-S
iba AG 2012
The ibaFOB-4i-S or ibaFOB-io-S devices represent the new generation of iba's fiber optic
PC boards. These boards replace the ibaFOB x/4, ibaFOB x/4-F and ibaFOB 2/2 IO
boards which were based on the PC ISA bus definition. The new boards are 100% com-
patible on the fiber optical bus side while in the PC the interface and dual port ram layout
differ between the old and new boards.
The new cards features are:
Full Plug&Play functionality.
Enhanced throughput on the PC bus side.
Enhanced card diagnostics and card information (LEDs and 7-segment display).
Two modes of operation: F-mode and M-mode, to be selected for each FO-port in-
dividually
Optional synchronization modules for synchronizing multiple systems in conjunction
with ibaScope

ibaFOB-4i-S / -io-S Manual Page 7
iba AG 2012
2Scope of Delivery
The following components are included with the delivery.
ibaFOB-4i-S or ibaFOB-io- PCI device (6-wire flat ribbon cable with four jacks for
iba card synchronization)
Manual
3Safety Information
Please consider the following safety advises:
W A R N I N G!
To avoid electrical shock during installation or uninstallation of the device
disconnect the power supply from the computer before opening.
C A U T I O N !
This board contains components which can be destroyed by electrostatic discharge.
Prior to touching any electronics board, your body must be electrically discharged. This
can be simply done by touching a conductive, grounded object immediately beforehand
(e.g. bare metal cabinet components, socket protective conductor contact).

Page 8 Manual ibaFOB-4i-S / -io-S
4Installation / Uninstallation
4.1 Preparation
The card fits in every compatible PCI slot.
C A U T I O N !
Use a ground line or discharge any electrostatic charge from yourself before touching
the card.
The standards for handling electrostatic sensitive devices (ESD) must be followed.
Note
Please follow carefully the advises below. Not to do so may void your warranty.
Remove and install cards only in a ESD designated workspace.
Remove all power connections from the PC before opening the PC and/or install-
ing/removing any device.
Never remove or (un-)solder chips or other parts of the device because this may
damage the device and void your warranty.
iba AG 2012

ibaFOB-4i-S / -io-S Manual Page 9
iba AG 2012
4.2 Installing the Card
1
Switch off the PC, disconnect it from power supply and open it, so that you
can see the PCI slots.
2 Unpack the card carefully. Use a ground line or discharge any electrostatic
charge from yourself before touching the card.
3 No settings of jumpers or switches are required.
4 Take hold of the card on the board edges and the front panel.
5 Press the card carefully into the desired PCI connector of the main board
Check that the card is fully
.
plugged into the slot and fix the card with the
Close the computer, connect the power supply and start it.
4.3
computer, disconnect it from the power supply and
3 Pull out the card off the PCI slot carefully and put in a safe place or conduc-
tive plastic bag.
screw on the front panel.
6
Removing the Card
In order to remove the card from the PC please follow these steps:
1 Stop and switch off the
open it.
2 Release the screw in the front panel.

Page 10 Manual ibaFOB-4i-S / -io-S
iba AG 2012
5System Requirements
5.1 Hardware
IBM-compatible PC with the following minimum configuration:
400 MHz Pentium II or better
At least one free PCI slot
128 MB RAM or better
Please see http://www.iba-ag.com for further details on a properly outfitted workstation.
5.2 Software
Microsoft Windows NT 4.0 (Service Pack 5 or higher), 2000, XP or 2003 Server
ibaPDA Version 4.0 with PCI support or higher, > 10 GB disk space
ibaLogic
ibaScope
ibaQDR
Table of contents
Other IBA Computer Hardware manuals

IBA
IBA ibaLink-VME User manual

IBA
IBA ibaFOB-TDCexp User manual

IBA
IBA ibaFOB-D User manual

IBA
IBA Com-L2B-4-8 User manual

IBA
IBA ibaPADU-S-IT-2x16 User manual

IBA
IBA ibaW-750 User manual

IBA
IBA FOB-SDexp User manual

IBA
IBA ibaFOB-PlusControl User manual

IBA
IBA ibaPADU-S-IT-16 User manual

IBA
IBA FOB-SD User manual
Popular Computer Hardware manuals by other brands

EMC2
EMC2 VNX Series Hardware Information Guide

Panasonic
Panasonic DV0PM20105 Operation manual

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 user manual

Gigabyte
Gigabyte B660M DS3H AX DDR4 user manual

Raidon
Raidon iT2300 Quick installation guide

National Instruments
National Instruments PXI-8186 user manual