Hunter Type 5 Models Instruction manual

Type 5 ModelsType 5 ModelsType 5 Models
Form# 42858-01
20090910
©2009 Hunter Fan Co.
For Your Records and
Warranty Assistance
For reference, also attach your receipt or a copy
of your receipt to the manual.
__________________________________________
Model Name
__________________________________________
Model No.
__________________________________________
Date Purchased
__________________________________________
Where Purchased
English Español
Owner’s Guide and Installation Manual

2
42858-01 • 09/10/09 • Hunter Fan Company
© 2009 Hunter Fan Company
Your new Hunter® ceiling fan is an addition to your home or oce that
will provide comfort and performance for many years. is installation
and operation manual gives you complete instructions for installing
and operating your fan.
We are proud of our work. We appreciate the opportunity to supply
you with the best ceiling fan available anywhere in the world.
Before installing your fan, for your records and warranty assistance,
record information from the carton and Hunter nameplate label
(located on the top of the fan motor housing).
Cautions and Warnings
•READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING
INSTALLATION. SAVE THESE INSTRUCTIONS.
• Use only Hunter replacement parts.
• To reduce the risk of personal injury, attach the fan directly to the
support structure of the building according to these instructions,
and use only the hardware supplied.
• To avoid possible electrical shock, before installing your fan,
disconnect the power by turning o the circuit breakers to the
outlet box and associated wall switch location. If you cannot lock
the circuit breakers in the o position, securely fasten a prominent
warning device, such as a tag, to the service panel.
• All wiring must be in accordance with national and local electrical
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualied electrician.
• To reduce the risk of personal injury, do not bend the blade
attachment system when installing, balancing, or cleaning the fan.
Never insert foreign objects between rotating fan blades.
• To reduce the risk of re, electrical shock, or motor damage, do not
use a solid-state speed control with this fan. Use only Hunter speed
controls.
Welcome
Table Of Contents
1 • Getting Ready......................... 4
2 • Installing the Ceiling Plate . . . . . . . . . . . . . 5
3 • Assembling Pipe / Ball Assembly . . . . . . . 6
4 • Assembling and Hanging the Fan . . . . . . 7
5 • Wiring the Fan ........................ 8
6 • Installing the Canopy . . . . . . . . . . . . . . . . . . 9
7 • Assembling the Blades. . . . . . . . . . . . . . . . 10
8 • Completing Your Installation With a
Bowl Light Fixture . . . . . . . . . . . . . . . . . 11
9 • Replacing e Light Bulb . . . . . . . . . . . . . 14
10 • Operating and Cleaning Your Ceiling
Fan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
11 • Troubleshooting . . . . . . . . . . . . . . . . . . . . 16

3
42858-01 • 09/10/09 • Hunter Fan Company
Installer’s Choice and Optional Accessories
Understanding Mounting and Installer’s Choice®
Hunter’s patented 2-position mounting system provides you maximum
installation exibility and ease. You can install your Hunter fan in
one of two ways, depending on ceiling height and your preference:
Standard, or Angle mounting. e steps in this manual include
instructions for only one Installer’s Choice mounting method.
Considering Optional Accessories
Consider using Hunter’s optional accessories, including a wall-mounted
or remote speed control. To install and use the accessories, follow
the instructions included with each product. For quiet and optimum
performance of your Hunter fan, use only Hunter speed controls.
For ceilings higher than 8 feet, you can purchase
Hunter extension downrods. All Hunter fans use
sturdy 3/4” diameter pipe to assure stability and
wobble-free performance.
Standard Mounting hangs from the
ceiling by a downrod (included).
Support Brace
Standard
Mounting
Style
Ceiling
Outlet Box
CAUTION: To reduce the risk of personal
injury, attach the fan directly to the support
structure of the building according to these
instructions, and use only the hardware
supplied.
Angle Mounting recommended for a
vaulted or angled ceiling
Support Brace
Ceiling
Outlet Box
Angle
Mounting
Style
8
12

4
42858-01 • 09/10/09 • Hunter Fan Company
To install a ceiling fan, be sure you can do the following:
• Locate the ceiling joist or other suitable support in ceiling.
• Drill holes for and install wood screws.
• Identify and connect electrical wires.
• Lift 40 pounds.
If you need help installing the fan, your Hunter fan dealer can direct
you to a licensed installer or electrician.
Gathering the Tools
You will need the following tools for installing the fan:
• Electric drill with 9/64” bit
• Standard screwdriver (magnetic tip recommended)
• Phillips-head screwdriver (magnetic tip recommended)
• Wrench or pliers
• Ladder (height dependent upon installation site)
Checking Your Fan Parts
Carefully unpack your fan to avoid damage to the fan parts. Refer to
the included Parts Guide. Check for any shipping damage to the motor
or fan blades. If any parts are missing or damaged, contact your Hunter
dealer or call Hunter Technical Support Department at 888-830-1326
(In Canada, call 1-866-268-1936).
Preparing the Fan Site
Before you begin installing the fan, follow all the instructions in
the pullout sheet called “Preparing the Fan Site.” Proper ceiling fan
location and attachment to the building structure are essential for
safety, reliable operation, maximum eciency, and energy savings.
Installing Multiple Fans?
If you are installing more than
one fan, keep the fan blades and
blade irons (if applicable) in sets,
as they were shipped.
1 • Getting Ready

5
42858-01 • 09/10/09 • Hunter Fan Company
CAUTION: To avoid possible electrical shock, before installing your fan,
disconnect the power by turning o the circuit breakers to the outlet box
and associated wall switch location. If you cannot lock the circuit breakers
in the o position, securely fasten a prominent warning device, such as a
tag, to the service panel.
2-1. Drill two pilot holes into the wood support structure through the
outermost holes in the outlet box. e pilot holes should be 9/64”
in diameter.
2-2. Align the slotted holes in the ceiling plate with the pilot holes you
drilled in the wood support structure. For proper alignment use
slotted holes directly across from each other.
2-3. Place the ceiling gasket over the ceiling plate so that the slots and
the raised surfaces on the ceiling gasket align with the slots and
holes on the ceiling plate.
2-4. Use a 3” wood screw to pierce two holes in the ceiling gasket that
match the pilot holes you drilled in step 2-1.
2-5. read the lead wires from the outlet box down through the hole
in the middle of the ceiling gasket and ceiling plate.
Note: e ceiling gasket should be ush against the ceiling.
Tighten the screws into the 9/64” pilot holes; do not use lubricants
on the screws. Do not over tighten.
Flat Washer
3” Wood Screw
Step 2-2
For Angled Ceilings: Be sure to
orient the ceiling plate so that the
arrows printed on the ceiling plate are
pointing toward the ceiling peak.
2 • Installing the Ceiling Plate

6
42858-01 • 09/10/09 • Hunter Fan Company
3 • Assembling Pipe / Ball Assembly
6
Figure 3b
Figure 3a 2 1/2”
Pipe
4 1/2” Pipe / Ball
Assembly
Positioning
Screw
Pin
Your Hunter fan comes with an optional downrod extension pipe. If
you would like to use the enclosed optional downrod, complete the
steps below.
If you are going to install the fan using the standard downrod, go to
“Step 4 - Assembling the Fan.”
Removing Ball Assembly
For the following steps refer to Figures 3b and 3c.
3-1. Locate the 4 1/2" pipe/ball assembly.
3-2. Remove the positioning screw from the top of the ball.
Note: e ball will become loose and should slide down the pipe.
3-3. Remove the ball from the pipe.
3-4. Remove the pin from the pipe.
3-5. Carefully loosen and remove the ground screw/leadwire assembly
from the pipe.
3-6. Locate the 2 1/2" pipe.
3-7. Insert and tighten the ground screw/leadwire assembly into the
small screw hole on one end of the 2 1/2" pipe.
3-8. Insert the pin into the two holes in the 2 1/2" pipe so that the pin
is placed evenly in the hole.
3-9. Insert the threaded end of the pipe into the at side of the ball.
3-10. Align the cutouts in the ball with the pin and the ground screw
assembly.
3-11. Slide the ball up the pipe until it hits the pin.
3-12. Insert and tighten the positioning screw into the ball so that the
head of the screw is placed on the end of the pipe.
Note: Make sure that the ball is positioned so that it is level or
straight.
Figure 3c
Ball
Ground
Screw
Leadwire
Assembly
CAUTION
• Make sure that the leadwire asembly is
pointing straight up and away from the pipe
• To avoid possible electrical shock, the
ground screw must be tightened securely.
• Failure to complete the steps above
properly could result in the fan falling.
• Do not overtighten the postioning screw
as it may cause the ball to seat improperly,
resulting in fan wobble andthe fan haing
crokedly

7
42858-01 • 09/10/09 • Hunter Fan Company
Steps 4-2 – 4-3
Downrod
Canopy
Set Screw
WARNING: Fan may fall if not assembled as directed in these
installation instructions.
4-1. Unbundle the wires from the fan.
For Standard or Angle mounting:
4-2. To assemble fan to hang down from a at or angled ceiling, insert
the downrod through the canopy. Feed the wires from the fan
through the downrod.
4-3. Loosen the square head set screw on the adapter to install the
pipe and ball assembly. Note: When the pipe and ball assembly
is fully installed, 2-3 threads on the pipe will still be visible; this is
normal. Securely retighten the set screw with a wrench or pliers.
CAUTION: e adapter has a special coating on the threads. Do
not remove this coating; the coating prevents the downrod from
unscrewing. Once assembled, do not remove the downrod.
4-4. Raise the fan and place the hook on the ceiling plate through the
U-shaped hole in the rim.
Step 4-4
U-shaped
Hole
4 • Assembling and Hanging the Fan

8
42858-01 • 09/10/09 • Hunter Fan Company
fsdfsdf
All wiring must be in accordance with national and local electrical
codes and ANSI/NFPA 70-1999. If you are unfamiliar with wiring,
use a qualified electrician.
Wall switches are not included. Select an acceptable general-use switch
in accordance with national and local electrical codes.
5-1. Before attempting installation, make sure the power is still o.
5-2. To connect the wires, hold the bare metal leads together and place
a wire nut over them, then twist clockwise until tight. For all these
connections use the wire connectors provided.
5-3. Connect the bare or green ground wire (grounding) from the
ceiling to the green ground wire (grounding) from the ceiling plate
and the green ground wire from the fan.
5-4. Connect the white wire (grounded) from the ceiling to the white
wire (grounded) from the fan.
5-5. Connect the remaining wires as follows:
Dual Switch Wiring:
• e black wire (ungrounded) from the ceiling to the black wire
(ungrounded) from the fan
• e black/white wire (ungrounded) from the fan to the wire
(ungrounded) for the wall switch
Single Switch Wiring:
• e black wire (ungrounded) from the ceiling to the black
(ungrounded) and the black/white wire (ungrounded) from
the fan
CAUTION: Be sure no bare wire or wire strands are visible after
making connections.
5-6. Turn the splices upward and push them carefully back through the
ceiling plate into the outlet box.
5-7. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the
outlet box.
Single Switch Wiring
Dual Switch Wiring
Wire
Connector
5 • Wiring the Fan

9
42858-01 • 09/10/09 • Hunter Fan Company
Step 6-2
Step 6-3
Canopy
Screw
6-1. Partially install two canopy screws into the ceiling plate and rotate
one time.
6-2. Holding the canopy, raise the fan o the hook.
6-3. Align the slots in the canopy with the already partially installed
canopy screws on the ceiling plate.
6-4. Raise the canopy over the ceiling plate. Rotate the canopy
clockwise until the canopy screws on the ceiling plate totally
engage with the slots in the canopy.
6-5. Install the third canopy screw into the canopy. Once all three
screws are in, tighten them.
Note: If the tabs are already engaged, do not rotate.
Canopy
Ceiling Plate
Step 6-4 Ceiling Plate
Hanger
Ball
Canopy
Screw
6 • Installing the Canopy

10
42858-01 • 09/10/09 • Hunter Fan Company
Steps 7-1 – 7-3
Hunter fans use several styles of fan blade irons (brackets that hold the
blade to the fan).
7-1. Install the grommets into the blades by hand.
7-2. Place each blade between a blade iron and medallion. Install three
blade screws to attach the medallion to the blade iron. Repeat for
all blades.
7-3. For each blade, insert one blade mounting screw through the
blade iron, and attach lightly to the fan. Insert the second blade
mounting screw, then securely tighten both mounting screws.
Blade Assembly
Screws
Use with grommet
Use without grommet
Blade
Mounting
Screw
7 • Assembling the Blades
Grommet
Step 7-1 (Detail)
Other manuals for Type 5 Models
3
Table of contents
Other Hunter Fan manuals

Hunter
Hunter 42747-01 User manual

Hunter
Hunter Lantern Bay 59581 User manual

Hunter
Hunter Alexander 51939 User manual

Hunter
Hunter Hunter Ceiling fans User manual

Hunter
Hunter 28537 User manual

Hunter
Hunter 2nd Century Original User manual

Hunter
Hunter 59629 User manual

Hunter
Hunter 23710 Manual

Hunter
Hunter Type A User manual

Hunter
Hunter SPA SELECT 90051 User manual

Hunter
Hunter 52271 User manual

Hunter
Hunter Highbury Instruction manual

Hunter
Hunter Orleans 82006 User manual

Hunter
Hunter 23783 Manual

Hunter
Hunter 28078 Manual

Hunter
Hunter Protos User manual

Hunter
Hunter 90220 User manual

Hunter
Hunter 22390 User manual

Hunter
Hunter 20422 Manual

Hunter
Hunter 45043-01 Instruction manual





















