Hunter TRAK User manual

INSTALLATION
MANUAL
TRAK

2
In a world full of impersonators,
be an original. We invented the
modern ceiling fan, and we stand
behind our products.
AUTHENTICITY
CONTENTS
!BEFORE YOU BEGIN
INSTALLATION
REFERENCE
SAFETY & PRECAUTIONS 3
FAN PLACEMENT 6
PRE-INSTALLATION 9
TOOLS NEEDED 10
IN THE BOX 11
STEP 1: PREPARATION 12
STEP 2: CEILING BRACKET 13
STEP 3: DOWNROD 14
STEP 4: MOTOR ASSEMBLY 15
STEP 5: RETENTION SYSTEM 16
STEP 6: WIRING 17
STEP 7: MOUNTING 18
STEP 8: BLADES 19
STEP 9: REMOTE CONTROL 20
MAINTENANCE 21
TROUBLE SHOOTING 22
1886
The Hunter legacy is not only
about quality—it’s about longevity.
We invented the modern ceiling
fan. We build fans that last, fans
that are designed as fans. We
design our fans while considering
each person in the process—from
the installer to the owner.
LEGACY

3
!BEFORE YOU BEGIN SAFETY & PRECAUTIONS
Important Safety Information
To prevent SERIOUS INJURY, DEATH and PROPERTY DAMAGE, you should read, understand and follow the warnings and instructions in this
manual before installing or operating the fan.
FIRE, ELECTRIC SHOCK and CRUSH HAZARDS.
To prevent SERIOUS INJURY or DEATH:
• To reduce the risk of re, electrical shock, or personal injury, mount fan directly from building structure and/or an
outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the
outlet box.
• To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the
circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the
off position, securely fasten a prominent warning device, such as a tag, to the service panel.
• To reduce the risk of electric shock, this fan must be installed with an isolating wall control/switch.
• To reduce the risk of personal injury, do not insert foreign objects in between rotating fan blades.
• Chemical burn hazard. Keep batteries away from children. This remote contains a lithium button cell battery. If a new
or used lithium button/coin cell battery is swallowed or enters the body, it can cause severe internal burns and can
lead to death in as little as 2 hours. Always completely secure the battery compartment. If the battery compartment
does not close securely, stop using the product, remove the batteries, and keep it away from children. If you think
batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
Dispose of cells properly and keep away from children. Even used cells may cause injury.
Installation, Adjustment, Repair or Maintenance Must Be Performed By Qualied Personnel.
Follow all safety practices and instructions during the installation, operation and servicing of the fan. Failure to apply these safety practices
could result in death or serious injury. If you do not understand the instructions, please call our Technical Department at 1-844-593-FANS
(3267) for guidance.
Always Check Federal, State and Local Codes Before Installing Fan.
Code compliance is the responsibility of the installer. Check all relevant codes to make sure that all product certications, product listings
and building regulations are met.
READ AND SAVE THESE INSTRUCTIONS. This manual must always be kept with the fan and should remain with the fan if
it is transferred or sold. Always give manual to fan owner following installation.
5007479

4
!BEFORE YOU BEGIN SAFETY & PRECAUTIONS
To prevent serious injury or death:
• BEFORE installing or servicing your fan, ALWAYS disconnect the power by turning off the circuit breaker or breakers, to the
fan locations and conrm Lockout/Tagout procedures are in place. If you cannot lock the circuit breakers in the off position,
securely fasten a prominent warning device, such as a tag, to the electrical panel.
• All wiring must be in accordance with national and local electrical codes, including ANSI/NFPA 70. If you are unfamiliar with
wiring or are in doubt, consult a qualied electrician.
• Do not use extension cord with fan.
• Do not remove covers while power is on.
• Do not use improper voltage source.
All fan controls and incoming power should be installed only by qualied technicians familiar with the requirements of the National Electrical Code
and local codes. Failure to follow these guidelines will void the manufacturer’s warranty.
All electrical controls are congured at the factory and are ready to use. No user adjustments are available. Follow the included installation
instructions when installing this device to ensure proper operation. Do not make any changes to any part of the fan without rst consulting Hunter
Industrial Fan. Installation is to be in accordance with ANSI/NFPA 70: National Electrical Code and local codes.
The user is responsible for compliance with all international and National Electrical Code requirements with respect to grounding of all equipment.
Many of the parts of this unit operate at line voltage.
Before installing, servicing or cleaning the unit, switch power off at the service panel, lock the service disconnecting means and conrm Lockout/
Tagout procedures are in place to prevent power from being switched on accidentally. When the service disconnect means cannot be locked,
securely fasten a prominent warning sign, such as a tag, to the service panel.
To reduce the risk of electric shock, serious injury and death, only use this unit as intended by the manufacturer. If you have any questions, call
our Technical Department at 1-844-593-FANS (3267).
Electric Shock Hazard

5
!BEFORE YOU BEGIN SAFETY & PRECAUTIONS
To prevent serious injury or death, ALWAYS attach the Retention Cable to the fan motor and secure to the building structure on
EVERY fan.
The Retention Cable limits the distance the fan could fall in the unlikely event of mounting system failure. Failure to install and to secure the
Retention Cable will void your warranty.
Weight and Torque Considerations
Always mount fan directly to building structure that can withstand approximately double (2x) the maximum hanging weight of the fan.
The hanging weight of a 8’ fan with a standard 11” downrod is 50 lbs. The maximum hanging weight of a 8’ fan with a 59” downrod is 55
lbs and a maximum torque of 7 ft-lbs.
Hunter Fan provides guidelines for mounting fans; however, it is the sole responsibility of the building owner and installer to ensure the
safety of the mounting system and Retention Cable, the building structure is sound, and the installation complies with all federal, state and
local codes.
Damaged Equipment
Never operate or install any fans or fan accessories that appear to be damaged. Failure to follow this instruction can result in death, serious
injury or equipment damage.
To reduce the risk of personal injury, do not bend the blades or blade holders when installing or cleaning the fan.
Do not insert foreign objects in between rotating fan blades.
Service
If the fan does not operate properly using the procedures in this manual, remove all power to the unit and contact our Technical Department
for further assistance at 1-844-593-FANS (3267).
Always Use Personal Protective Equipment
You should always wear Personal Protective Equipment, such as a Hard Hat, Safety Glasses and a Fall Harness when installing fans.
CRUSH HAZARD

6
!BEFORE YOU BEGIN CHOOSE THE RIGHT LOCATION
Checking the Ceiling Angle:
Angled Mounting
If you have an angled or vaulted ceiling:
1. You will need a longer downrod.
Check the room dimensions: Check the outlet box:
You must be able to
secure the fan to building
structure or fan-rated
outlet box and clearly
marked acceptable for
fan support of 70 lbs
(31.8 kg) or less.
30 inches
from blade tip to
nearest wall or
obstruction 10 feet
from bottom edge
of blade to the
oor
Support
Structure
Ceiling Outlet
Box (required)
Angled Mounting
If you have a at ceiling:
Hang your fan by a standard downrod. For tall ceilings
you may need a longer downrod.
Support Structure
Ceiling Outlet
Box (required)
Standard Mounting
A little more information on Angled Mounting:
For optimum performance and appearance, a longer downrod should be
used with your Hunter ceiling fan when installing on high or angled ceiling.
Determining angle of ceiling:
Fold on the dotted line. Place long edge againts the
wall. Slide towards the ceiling. If the guide touches
the wall but not the ceiling, your ceiling is greater
than 34°.
Hunter Pro Tip:
CEILING
WALL
34°
Fan can not be mounted on to a
ceiling with an angle greater than 34°
NOTICE

7
!BEFORE YOU BEGIN FAN PLACEMENT
FAN PLACEMENT
FAN SPACING CHART
MIN - MAXDIA
A B
TRAK
18ft - 28ft
16ft - 24ft
14ft - 20ft
8ft (96”)
7ft (84”)
6ft (72”)
5ft (60”)
20ft - 32ft
A
B

8
!BEFORE YOU BEGIN FAN PLACEMENT
ALWAYS mount fan so the bottom edge of blade to the oor is at least 10 feet.
Always mount fans away from the following:
Sprinkler Systems
Prior to installing fans, review all codes applicable to sprinkler systems and fans to ensure code compliance and refer to NFPA 13: Fire
Sprinkler System Installation. In any installation where re sprinklers are present, the fan should not interfere with their operation.
o Fans should be located at least 3 feet below a sprinkler deector.
o Fans should be centered between 4 adjacent sprinklers.
It is your responsibility that the installation complies with the applicable codes. For assistance, please call our Technical Department at 1-844-
593-FANS (3267).
Walkways and Mezzanines
If the building has elevated walkways or mezzanines, mount the fans so that a person cannot reach the rotating blades in any way. Position
fans so that the tips of the blades are at least 5 feet away from any area where a person may be able to extend outward to reach them.
Lights and Skylights
If possible, avoid mounting fans directly below lights or skylights to avoid any strobe effect caused by moving blades.
There should be a minimum of 2 feet between the blades and any light xture.
Air Discharge Locations
Fans should not be located directly beneath or in line with any air discharge. This includes air conditioning units and evaporative coolers.Such
equipment can be used effectively in conjunction with ceiling fans however the discharge of the unit must be located outside the swept area
of the fan and at a distance of at least two times the diameter.

9
BEFORE YOU BEGIN PRE-INSTALLATION CHECKLIST
The location of the fan will alow for a minumum of 2 feet of blade clearance from
any obstruction and at least 10 feet of clearance above the oor.
If installing multiple fans, reference the fan placement chart for optimal spacing.
The control panel voltage markings (either 100-120VAC or 220-240VAC) should match
your building supply power.
Assess location
30 inches
from blade tip to
nearest wall or
obstruction 10 feet
from bottom
edge of blade
to the oor
Know your wiring
If you are unfamiliar
with wiring, use a
qualied electrician.
Must be able to
secure the fan to
building structure or
fan-rated outlet box
Select a downrod length
1
2
Standard Downrod
for ceilings 12-14 feet high
Longer Downrod
for ceilings 14 feet or higher
Assess ceiling angle
Maximum ceiling
angle is 34°.
!

10
BEFORE YOU BEGIN TOOLS NEEDED
Ladder Screwdrivers
1/2”/ M4 Wrench
x2
Included
Right Angled Screwdriver
Allen Wrench Blade Installation Tool
!
Table of contents
Other Hunter Fan manuals

Hunter
Hunter N6SY User manual

Hunter
Hunter M3544-01 User manual

Hunter
Hunter Hunter Ceiling Fan User manual

Hunter
Hunter 99183 User manual

Hunter
Hunter 28679 Manual

Hunter
Hunter 23947 Instruction Manual

Hunter
Hunter 28449 Manual

Hunter
Hunter 28672 Service manual

Hunter
Hunter 28078 Instruction manual

Hunter
Hunter 28790 User manual

Hunter
Hunter 28789 Instruction Manual

Hunter
Hunter Romulus User manual

Hunter
Hunter Grand Cayman Instruction manual

Hunter
Hunter 21978 Manual

Hunter
Hunter 23710 Instruction Manual

Hunter
Hunter Astwood User manual

Hunter
Hunter MB502-01 User manual

Hunter
Hunter 42008-01 User manual

Hunter
Hunter Ashbury 81001 User manual

Hunter
Hunter MD506-01 Product information sheet