Hunter 45041-01 Instruction manual

w
Type 2 ModelsType 2 ModelsType 2 Models
Form# 45041-01
20090930
©2009 Hunter Fan Co.
For Your Records and
Warranty Assistance
For reference, also attach your receipt or a copy
of your receipt to the manual.
__________________________________________
Model Name
__________________________________________
Model No.
__________________________________________
Date Purchased
__________________________________________
Where Purchased
English
Owner’s Guide and Installation Manual

2
45041-01 • 09/30/09 • Hunter Fan Company
Table of Contents
1 • Getting Ready ...................................................4
2 • Installing the Ceiling Plate.......................... 5
3 • Assembling the Fan .......................................6
4 • Hanging and Wiring the Fan.....................7
5 • Installing the Canopy and Canopy
Trim Ring..............................................................8
6 • Assembling the Blades................................. 9
7 • Completing Your Installation With
or Without a Light Fixture....................... 10
8 • Operating and Cleaning
Your Ceiling Fan............................................. 14
9 • Troubleshooting ........................................... 15
© 2009 Hunter Fan Company
Your new Hunter® ceiling fan is an addition to your home or oce that
will provide comfort and performance for many years. is installation
and operation manual gives you complete instructions for installing
and operating your fan.
We are proud of our work. We appreciate the opportunity to supply
you with the best ceiling fan available anywhere in the world.
Before installing your fan, for your records and warranty assistance,
record information from the carton and Hunter nameplate label
(located on the top of the fan motor housing).
Cautions and Warnings
•READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING
INSTALLATION. SAVE THESE INSTRUCTIONS.
• Use only Hunter replacement parts.
• To reduce the risk of personal injury, attach the fan directly to the
support structure of the building according to these instructions,
and use only the hardware supplied.
• To avoid possible electrical shock, before installing your fan,
disconnect the power by turning o the circuit breakers to the
outlet box and associated wall switch location. If you cannot lock
the circuit breakers in the o position, securely fasten a prominent
warning device, such as a tag, to the service panel.
• All wiring must be in accordance with national and local electrical
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualied electrician.
• To reduce the risk of personal injury, do not bend the blade
attachment system when installing, balancing, or cleaning the fan.
Never insert foreign objects between rotating fan blades.
• To reduce the risk of re, electrical shock, or motor damage, do not
use a solid-state speed control with this fan. Use only Hunter speed
controls.
Welcome

3
45041-01 • 09/30/09 • Hunter Fan Company
Installer’s Choice and Optional Accessories
Understanding Mounting and Installer’s Choice®
Hunter’s patented 3-position mounting system provides you maximum
installation exibility and ease. You can install your Hunter fan in one
of three ways, depending on ceiling height and your preference: Low
Prole, Standard, or Angled mounting. e steps in this manual include
instructions for all three Installer’s Choice mounting methods.
Considering Optional Accessories
Consider using Hunter’s optional accessories, including a wall-mounted
or remote speed control. To install and use the accessories, follow
the instructions included with each product. For quiet and optimum
performance of your Hunter fan, use only Hunter speed controls.
For ceilings higher than 8 feet, you can purchase
Hunter extension downrods. All Hunter fans use
sturdy 3/4” diameter pipe to assure stability and
wobble-free performance.
Standard Mounting hangs from the
ceiling by a downrod (included).
Angled Mounting recommended for a
vaulted or angled ceiling
Support Brace
Standard
Mounting
Style
Ceiling
Outlet Box
Support Brace
Ceiling
Outlet Box
Angled
Mounting
Style
Low Profile Mounting ts close to the
ceiling, recommended for ceilings less
than 8 feet high
Support Brace
Low Prole
Mounting
Style
Ceiling
Outlet Box
8
12
CAUTION: To
reduce the risk of
personal injury, attach
the fan directly to the
support structure of
the building according
to these instructions,
and use only the
hardware supplied.

4
45041-01 • 09/30/09 • Hunter Fan Company
1 • Getting Ready
To install a ceiling fan, be sure you can do the following:
• Locate the ceiling joist or other suitable support in ceiling.
• Drill holes for and install wood screws.
• Identify and connect electrical wires.
• Lift 40 pounds.
If you need help installing the fan, your Hunter fan dealer can direct
you to a licensed installer or electrician.
Gathering the Tools
You will need the following tools for installing the fan:
• Electric drill with 9/64” bit
• Standard screwdriver (magnetic tip recommended)
• Phillips-head screwdriver (magnetic tip recommended)
• Wrench or pliers
• Ladder (height dependent upon installation site)
Checking Your Fan Parts
Carefully unpack your fan to avoid damage to the fan parts. Refer to
the included Parts Guide. Check for any shipping damage to the motor
or fan blades. If any parts are missing or damaged, contact your Hunter
dealer or call Hunter Technical Support Department at 888-830-1326
(In Canada, call 1-866-268-1936).
Preparing the Fan Site
Before you begin installing the fan, follow all the instructions in
the pullout sheet called “Preparing the Fan Site.” Proper ceiling fan
location and attachment to the building structure are essential for
safety, reliable operation, maximum eciency, and energy savings.
Installing Multiple Fans?
If you are installing more than
one fan, keep the fan blades and
blade irons (if applicable) in sets,
as they were shipped.

5
45041-01 • 09/30/09 • Hunter Fan Company
2 • Installing the Hanger Bracket
2-1. Drill two pilot holes into the wood support structure through the
outermost holes in the outlet box. e pilot holes should be 9/64”
in diameter.
Note: Your fan comes with four pre-installed neoprene noise
isolators.
2-2. read the lead wires from the outlet box down through the hole
in the middle of the hanger bracket.
2-3. Align the slotted holes in the hanger bracket with the pilot holes
you drilled in the wood support structure. For proper alignment
use slotted holes directly across from each other. If you are
installing the fan on an ANGLED ceiling, be sure to orient the
hanger bracket as shown in Illustration 2-3 (left or right view).
Note: e isolators should be ush against the ceiling.
2-4. Place a at washer on each of the two 3” screws and pass the
screws through the slotted holes in the hanger bracket into the
pilot holes you drilled.
Tighten the screws into the 9/64” pilot holes; do not use lubricants
on the screws. Do not over tighten.
Flat Washer
3” Screw
Steps 2-2 – 2-4
Hanger
Bracket
Isolator
Step 2-3 (Angled Ceiling Only)
OR
Ceiling Peak Ceiling Peak
Large
Opening Large
Opening
LEFT RIGHT

6
45041-01 • 09/30/09 • Hunter Fan Company
3 • Assembling and Hanging the Fan
You can assemble your fan for standard or angled mounting as shown
in steps 3-1 – 3-3. For low profile mounting (ceilings less than 8 feet
high), go to steps 3-6 – 3-9 on the next page.
3-1. To assemble fan to hang down from a at or angled ceiling, place
the canopy and canopy trim ring around the adapter so that they
rest on the fan assembly.
3-2. Feed the wires from the fan through the downrod.
Note: Make sure all the wires are on the same side of the metal
dowel pin inside the dowrod.
3-3. Loosen the square head setscrew on the adapter to install the pipe
and ball assembly. Note: When the pipe and ball assembly is fully
installed, 2-3 threads on the pipe will still be visible; this is normal.
Securely retighten the setscrew with a wrench or pliers.
CAUTION: e adapter has a special coating on the threads. Do
not remove this coating; the coating prevents the downrod from
unscrewing. Once assembled, do not remove the downrod.
WARNING: Do not carry or lift fan by canopy.
3-4. Raise the fan and place the ball into the hanger bracket.
3-5. Align the notch on the ball with the indent in the hanger bracket.
(Rotate the fan until you hear the notch pop into place.)
Go to 4 • Wiring the Fan.
WARNING: Fan may fall if not assembled as directed in these
installation instructions.
Steps 3-4 – 3-5
Indent
Steps 3-1 – 3-3
Downrod
Canopy
(with Washer)
Canopy
Trim
Ring
Setscrew
Adapter

7
45041-01 • 09/30/09 • Hunter Fan Company
3 • Assembling and Hanging the Fan (Low Profile Only)
You can assemble your fan for standard or angled mounting as shown
in steps 3-1 – 3-3 on the previous page. For low profile mounting
(ceilings less than 8 feet high), see steps 3-6 – 3-10 on this page.
3-6. Remove the screws from the hanger ball bracket.
3-7. Place the low prole washer from the parts sack into the canopy.
3-8. Place the canopy trim ring and canopy with washer on top of the
fan assembly.
3-9. Align the screw holes in the washer with the holes in the adapter.
Assemble securely with three #8-32 x 3/4” screws.
3-10. Raise the fan and place the hook on the hanger bracket through
the round hole in the rim of the canopy.
WARNING: Fan may fall if not assembled as directed in these
installation instructions.
Step 3-10
Step 3-7 (Detail)
Low Prole Washer
(Not Actual Size)
Steps 3-8 – 3-9
Low Prole Washer
Canopy
Trim Ring
Adapter
#8-32 x 3/4” Screw
Step 3-6

8
45041-01 • 09/30/09 • Hunter Fan Company
4 •Wiring the Fan
All wiring must be in accordance with national and local electrical
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualified electrician.
Wall switches are not included. Select an acceptable general-use switch
in accordance with national and local electrical codes.
4-1. Before attempting installation, make sure the power is still o.
4-2. To connect the wires, hold the bare metal leads together and place
a wire connector over them, then twist clockwise until tight. For
all these connections use the wire connectors provided.
4-3. Connect the bare or green ground wire (grounding) from the
ceiling to the green ground wire (grounding) from the ceiling plate
and the green ground wire from the fan or the green ground wire
present on the low prole washer.
4-4. Connect the white wire (ungrounded) from the ceiling to the
white wire (ungrounded) from the fan.
4-5. Connect the remaining wires as follows:
Dual Switch Wiring:
• e black wire (ungrounded) from the ceiling to the black wire
(ungrounded) from the fan
• e black/white wire (ungrounded) from the fan to the wire
(ungrounded) for the wall switch
Single Switch Wiring:
• e black wire (ungrounded) from the ceiling to the black
(ungrounded) and the black/white wire (ungrounded) from
the fan
CAUTION: Be sure no bare wire or wire strands are visible after
making connections.
4-6. Turn the wire connectors upward and push them carefully back
through the ceiling plate into the outlet box.
4-7. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the
outlet box.
Wire
Connector

9
45041-01 • 09/30/09 • Hunter Fan Company
5 • Installing the Canopy and Canopy Trim Ring
5-1. Partially install two canopy screws (about 2 full turns) in the
hanger bracket.
5-2. Raise the canopy over the hanger bracket. Align partially installed
screws with key slots in canopy.
5-3. Twist canopy clockwise to secure.
5-4. Install third & fourth canopy screw in round hole on canopy.
Securely tighten all four screws.
5-5. Using both hands, push the canopy trim ring up to the top of the
canopy.
5-6. Twist canopy trim ring clockwise to secure the canopy.
Should you need to remove the canopy
trim ring, follow these steps:
1. Twist canopy trim ring counter
clockwise until it releases from
canopy.
Steps 5-1 – 5-2
Canopy Trim
Ring
Canopy
Hanger Bracket
Step 5-3
Canopy
Screw
Step 5-4
Step 5-5

10
45041-01 • 09/30/09 • Hunter Fan Company
6 • Assembling the Blades
Hunter fans use several styles of fan blade irons (brackets that hold the
blade to the fan).
6-1. Your fan may include blade grommets. If your fan has grommets,
insert them by hand into the holes on the blades.
6-2. Attach each blade to a blade iron using three blade assembly
screws. If you used grommets, the blades may appear slightly loose
after screws are tightened. is is normal.
6-3. Remove the blade mounting screws and rubber shipping bumpers
from the motor. Note: Some blade mounting screws are installed
in the motor to secure shipping blocks.
6-4. For each blade, insert one blade mounting screw through the
blade iron, and attach lightly to the fan. Insert the second blade
mounting screw, then securely tighten both mounting screws.
Step 6-1 (Detail)
Blade Assembly
Screws
Use with grommet
Use without grommet
Grommet
Blade
Mounting
Screw
Steps 6-1 – 6-2
Step 6-4
Table of contents
Other Hunter Fan manuals

Hunter
Hunter 20422 Manual

Hunter
Hunter 51476 User manual

Hunter
Hunter 28685 Service manual

Hunter
Hunter 23970 Instruction manual

Hunter
Hunter 90220 User manual

Hunter
Hunter 20171 Instruction Manual

Hunter
Hunter 90052 Manual

Hunter
Hunter 22388 User manual

Hunter
Hunter 23965 Manual

Hunter
Hunter 82022 User manual

Hunter
Hunter 51224 User manual

Hunter
Hunter M0094-01 User manual

Hunter
Hunter Aker User manual

Hunter
Hunter 23714 Manual

Hunter
Hunter HFC HUN-59136 User manual

Hunter
Hunter 2nd Century Original User manual

Hunter
Hunter 28789 User manual

Hunter
Hunter Hunter Ceiling fans User manual

Hunter
Hunter 27196 User manual

Hunter
Hunter Mill Valley 59309 User manual





















