Hoover 7128-02 User manual

Table of Contents
Please read prior to installing this fan........................................................................................................ 2
Supplied parts .................................................................................................................................................... 2
Description .......................................................................................................................................................... 3
Dimensions .......................................................................................................................................................... 3
Wiring diagram................................................................................................................................................... 4
Specications ......................................................................................................................................................4
Reference specications .................................................................................................................................4
Unpacking ............................................................................................................................................................5
General safety information & warnings.....................................................................................................5
Installation I (Joist Mounting) ................................................................................................................... 6-7
Installation II (in Existing Construction) .................................................................................................... 8
Maintenance ....................................................................................................................................................... 9
Warranty .............................................................................................................................................................10
Warning: This fan is not intended for vertical, wall-mount installation.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-877-319-3757, 7 a.m. - 5 p.m., CST, Monday - Friday.
www.homewerksww.com
VENTILATING BATH
FAN WITH LIGHT
MODEL #7128-02
Español p. 11
Nov. 15, 2011
Hoover is a registerd trademark of Techtronic Industries
Limited and is being used underlicense by Homewerks
Worldwide, LLC.

Instructions
2www.homewerksww.com
PLEASE READ PRIOR TO INSTALLING THIS FAN
This line of ventilating fans employs state-of-the-art technology. Please read this entire
instruction booklet prior to installation to realize the benets the fan oers.
Outstanding Energy Savings: This fan meets or exceeds the minimum ENERGY STAR
requirements.
SUPPLIED PARTS
PART NAME APPEARANCE QUANTITY
Pan with light kit 1
Long wood screw 8
Short machine screw 4
Suspension bracket I 2
Suspension bracket II 2
* GU24 13-watt and 4-watt bulbs not included

Instructions
3www.homewerksww.com
DESCRIPTION
This ventilating fan uses a low-noise, fan-driven motor. The motor is designed and
manufactured to have an extended service life and operates very eciently. There
is a thermal cut-o for safety. The grille that covers the housing is spring loaded.
DIMENSIONS
12
1
2
3
4
5
6
7
89
10
11
15-3/8"
13-3/8"
8"
10-3/8"
12"
12"
8"
NO. Part Name NO. Part Name
1 Grille 7 Motion sensor
2 Spring clip 8 GU24 bulb 13W bulb (not included)
3 Junction box 9 Night lamp (4W bulb) (not included)
4 Outlet 10 Blower wheel
5 Damper 11 Bracket cover
6 Motor 12 Fan housing

Instructions
4www.homewerksww.com
WIRING DIAGRAM
Capacitor for
long life of motor
Red wire
Sensor
Black wire
White wire
White wire
Black wire
White wire
NIGHT LIGHT
LIGHT HOUSING
FAN H
OUS
IN
G
To separate
switch or circuit*
Black wire
White wire
Green wire
Up to 4 Watts
Up to 13 Watts
Up to 13 Watts
automatic terminal switch
motor
Junction box
to neutral
to neutral
to neutral
to ground
to switch
to switch
to 120V AC 60Hz
Green wire to ground
SPECIFICATIONS
Model No. Air
direction
V Hz Duct
diameter
(inches)
Noise
(sone)
Power
consumption
(W)
Speed
(rpm)
Air deliver
at 0.1" WG
(cfm)
Weight
kg (lb.)
7108-02-AD
7108-02-L
110CFM 120 60 4 1.2 32 860 110CFM 6
DIMENSIONS
Ceiling
Opening L
Ceiling
Opening W
Ceiling
Opening D
Housing
Dimension L
Housing
Dimension W
Housing
Dimension D
11.38" 10.5" 8.5" 10.5" 10.31" 8"
Be careful to cut hole exactly. If the hole is too big the fan grille will not hide it.
* NOTE: To use the night light function, the switch lead from the nightlight bulb and
sensor must be installed on a separate live switch or on a separate live circuit on
a 3-way switch. Combining the switch lead from the nightlight and sensor with
any other switch lead will turn o this function. This feature must remain on a
separate live circuit.
It is not necessary to use the nightlight feature. You may opt not to use this by
simply covering the bare ends of the wire leads and not connecting them to any
circuit. This will not change the performance or operation of this fan.

Instructions
5www.homewerksww.com
UNPACKING
Carefully remove unit from carton.
Refer to the Supplied Parts list on page 2 to verify that all parts are present.
GENERAL SAFETY INFORMATION & WARNINGS
1. Electric Service supply must be 120V 60Hz.
2. Follow all local safety and electrical codes as well as NEC (National Electrical Code) and
OSHA (Occupational Safety and Health Act).
3. This unit must be properly grounded.
4. Always disconnect the power supply prior to servicing the fan, motor or junction box.
5. Do not bend or kink the power wires.
6. Do not install where the room air temperature will exceed 40ºC (104ºF).
7. This ventilation fan is approved for use over a bathtub or shower when installed in a
GFCI protected circuit. Do not use fans over a bathtub or shower that are not approved
for that application and marked accordingly.
8. Do not use to exhaust hazardous or explosive vapors.
9. Do not install in a cooking area.
10. Do not install this fan vertically in a wall.
11. Use this unit in the manner intended by the manufacturer. If you have any questions
please call the manufacturer (customer service number located on last page).
12. Installation work must be carried out by a qualied person(s) in accordance to all local
and safety codes including the rules for re-rated construction.
13. Sucient air supply is required for proper combustion and the exhaustion of gases
through the chimney (ue) of fuel burning equipment to prevent back-drafting. See
the standards of NFPA (National Fire Protection Association) and ASHRAE (American
Society for Heating Refrigeration and Air Conditioning Engineers) and the local building
code authorities.
14. Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
15. Fans should always be vented to the exterior and in compliance with local codes.
16. Do not use this fan with any solid state control device.
17. Prior to service or cleaning this unit, shut o power supply at the panel and lock to
prevent the power from being turned on. If the panel cannot be locked, clearly mark
the panel with a warning tag to prevent the power from being turned on.
18. Do not install in a ceiling with insulation greater than R42.
19. Duct work should be installed in a straight line with minimal bends.
20. Duct work size must be a minimum of the discharge and should not be reduced.
Reducing the duct size can increase fan noise.

Instructions
6www.homewerksww.com
Insert
suspension
bracket
Suspension
bracket I
Suspension
bracket II
2 brass screws
FIG. 1
WARNING: Turn o electricity at breaker
box before beginning installation.
INSTALLATION I (JOIST MOUNTING)
1. Insert the suspension bracket into the fan
body. (If spacing between joists is 21-1/4 to
23-1/2 inches (540 to 597 mm), connect
suspension bracket I and II) (FIG. 1)
2. Mount the fan body to joist using the suspension
brackets and long wood screws.
(FIG. 2-1 or FIG. 2-2/2-3)
CAUTION: Dimension “B” should allow for
thickness of ceiling board used in your
applicaton. (FIG. 2-1a) DO NOT FLUSH
MOUNT TO JOIST. Flange should be ush
with ceiling board.
2 long
wood
screws
FIG. 2-3
Joist
Fan body
FIG. 2-1
Joist distance
(21-1/4" to 23-1/4")
Bracket
FIG. 2-1a
Fan body
Joist
Ceiling
B
Bracket
Fan body
Joist
FIG. 2-2

Instructions
7www.homewerksww.com
3. Refer to wiring diagram on page 4. Remove the juction
box cover. Using wire nuts, connect house electrical wires
to ventilating fan wires; black to black, white to white,
green to green. Replace the junction box cover. (FIG. 3)
CAUTION: If your house wires do not match these colors,
you must determine what each house wire represents
before connecting and you may need to consult an
electrical contractor to determine this safely. Mount
junction box cover carefully so lead wires are not
pinched.
4. Install a circular duct and secure it with duct tape or
clamps.
5. Finish ceiling work. Ceiling hole should be ush with the
edge of the ange. (DO NOT FLUSH MOUNT TO JOIST.
Flange should be ush with ceiling board.) See
dimensions for ceiling hole on page 4. (FIG. 4) If
joist is present, insert longwood screws through
ange and through ceiling to secure fan to joist.
6. Install bulbs (not included) and attach the cover.
(FIG. 5)
7. Attach plug connector to receptacle. (FIG. 5-1)
8. Pinch mounting springs and insert into narrow
rectangular slots inside the fan housing next to
the fan motor (FIG. 5-2).
9. Turn on electricity at breaker box after
nishing installation.
Fan body
black, white,
green
Duct
Wiring box
black, white,
green
FIG. 3
FIG. 4
Ceiling
Ceiling
Flange
Long wood
screws
FIG. 5
FIG. 5-2
Flange
Grille
Mounting
spring
FIG. 5-1
Receptacle
Flange
Ceiling
Plug connector
Slot for
mounting

Instructions
8www.homewerksww.com
INSTALLATION II (IN EXISTING CONSTRUCTION)
1. Installing the fan body in an existing building requires an accessible area
(attic or crawl or space) above the planned installation location and existing
duct and wiring.
(1) To install the fan body, follow the procedures described in Installation I.
Take the following precautions before installation.
CAUTION:
Check area above installation location to be sure that:
1. Duct work can be run and the area is sucient for proper ventilation.
2. Wiring can run to the planned location.
3. No wiring or other obstructions can interfere with the installation.
(2) Inspect duct work and wiring before proceeding with installation.
(3) Plan suitable location for fan body (next to ceiling joist). DO NOT FLUSH
MOUNT FLANGE TO CEILING JOIST.
(4) Before installation, provide inspection and future maintenance access at
a location that will not interfere with installation work.
(5) Remove ceiling section using dimensions provided on page 4. Be careful to cut hole
exactly. If the hole is too big the fan grille will not hide it.
(6) Install fan body.
(7) Continue steps 3-9 of Installation I (page 6-7) to complete the installation work.
2. Installation from accessible area (e.g. attic) above fan location.
(1) Inspect duct work and wiring before proceeding with installation.
(2) Remove ceiling section using dimensions provided on page 4.
(3) Install fan body.
(4) Continue steps 3-9 of Installation I (page 6-7) to complete the installation work.

Instructions
9www.homewerksww.com
MAINTENANCE
ELECTRICAL WARNING
Disconnect power supply before servicing. See
General Safety (Page 5) in this manual before
proceeding. Routine maintenance should be
done at least once a year.
CAUTION:
• Never use solvents, thinner or harsh chemicals
for cleaning the fan.
• Do not allow water to enter the motor.
• Do not immerse resin parts in water over
140 degrees Fahrenheit.
1. Remove grille by squeezing spring and pull
down (FIG. 7). Unplug receptacle and remove
light reector and bulbs before cleaning grille.
2. Dampen cloth with dish detergent, wipe the
grille and dry with a cloth.
3. Remove dust and dirt from the fan housing
with a vacuum cleaner. (FIG. 8)
4. Dampen cloth with dish detergent, wipe
the fan housing and dry with a cloth. (FIG. 9)
5. Replace the grille.
6. Use GU24, 13-watt bulbs (not included) to
maintain Energy Star rating.
FIG. 7
FIG. 8
Vacuum
FIG. 9

Instructions
10www.homewerksww.com
LIMITED 10-YEAR WARRANTY
If this product fails due to a defect in materials or workmanship at any time during the rst
TEN years of ownership, the manufacturer will replace it free of charge, postage-paid at
their option. Simply contact Customer Service at (1-877-319-3757) or visit our website
www.homewerksww.com for replacement information. This warranty does not cover
products which have been abused, altered, damaged, misused, cut or worn. This warranty
does not cover use in commercial applications. The manufacturer DISCLAIMS all other
implied or express warranties including all warranties of merchantability and/or tness
for a particular purpose. As some states do not allow exclusions or limitations on an
implied warranty, the above exclusions and limitations may not apply. This warranty
gives you specic legal rights, and you may have other rights that vary from state
to state.
THIS WARRANTY IS LIMITED TO THE REPLACEMENT OF DEFECTIVE PARTS ONLY.
Labor charges and/or damage incurred during installation, repair, replacement as well
as incidental and consequential damages connected with the above are excluded. Any
damage to this product as a result of neglect, misuse, accident, imporper installation
or use other than the purpose SHALL VOID THIS WARRANTY.
PRODUCT CUSTOMER SERVICE
If you should have any further questions please contact Customer Service toll free at 1-877-31WERKS
(1-877-319-3757) or visit our website www.homewerks.com.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Table of contents
Languages:
Other Hoover Fan manuals
Popular Fan manuals by other brands

ELTA FANS
ELTA FANS H03VV-F installation guide

Hunter
Hunter 20714 Owner's guide and installation manual

Emerson
Emerson CARRERA VERANDA CF542ORB00 owner's manual

Hunter
Hunter Caraway Owner's guide and installation manual

Panasonic
Panasonic FV-15NLFS1 Service manual

Kompernass
Kompernass KH 1150 operating instructions