Honeywell BW MicroDock II User manual

iERP: 126102
D5618/7 [English]
© BW Technologies 2008. All rights reserved.
Quick Reference Guide
Automatic Test and Calibration Station

Limited Warranty and Limitation Liability
BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal use and service for a period of
two years, beginning on the date of shipment to the buyer. This warranty extends only to the sale of new and unused products to the original buyer.
BW’s warranty obligation is limited, at BW’s option, to refund of the purchase price, repair or replacement of a defective product that is returned to
a BW authorized service center within the warranty period. In no event shall BW’s liability hereunder exceed the purchase price actually paid by the
buyer for the Product.
This warranty does not include:
a) fuses, disposable batteries or the routine replacement of parts due to the normal wear and tear of the product arising from use;
b) any product which in BW’s opinion, has been misused, altered, neglected or damaged, by accident or abnormal conditions of operation,
handling or use;
c) any damage or defects attributable to repair of the product by any person other than an authorized dealer, or the installation of unapproved
parts on the product; or
The obligations set forth in this warranty are conditional on:
a) proper storage, installation, calibration, use, maintenance and compliance with the product manual instructions and any other applicable
recommendations of BW;
b) the buyer promptly notifying BW of any defect and, if required, promptly making the product available for correction. No goods shall be
returned to BW until receipt by the buyer of shipping instructions from BW; and
c) the right of BW to require that the buyer provide proof of purchase such as the original invoice, bill of sale or packing slip to establish that the
product is within the warranty period.
THE BUYER AGREES THAT THIS WARRANTY IS THE BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. BW SHALL NOT BE LIABLE FOR ANY
SPECIAL, INDIRECT, INCIDENTAL, OR BASED ON CONTRACT, TORT OR RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential
damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this warranty is held invalid or
unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.
Contacting BW Technologies by Honeywell
Email us at: [email protected]
Visit BW Technologies by Honeywell’s website at: www.honeywellanalytics.com
Canada & USA: 1-888-749-8878 Other countries: 1-403-248-9226
Europe: 00800-333-222-44

1
MicroDock II
Introduction
a Warning
To ensure personal safety, read Safety Information - Read
First before using the MicroDock II base station.
The MicroDock II Automatic Test and Calibration Station (“the
base station”) provides automated calibration and bump testing
for the GasAlert Extreme, GasAlertClip Extreme, GasAlertMi-
cro, GasAlertMicro 5/PID/IR, GasAlertMicroClip / GasAlertMi-
croClip XT, GasAlertMax XT / GasAlertMax XT II, and
GasAlertQuattro. The system is expandable to include up to six
docking modules (maximum six charging docking modules)
Safety Information - Read First
Use the station only as specified in this guide. Read the follow-
ing Cautions before using the station.
a Cautions
• If the base station is damaged or parts are missing,
contact BW Technologies by Honeywell immediately.
• This equipment uses potentially harmful gas for
calibration. Use in a well-ventilated area only.
• The base station must be attached to a venting system or
the base station must be used in a well-ventilated area.
• Do not immerse the base station in liquids.
• The maximum recommended exhaust line length is
15.24 m (50 ft.).
• Ensure that the inlet filter is clean.
• Ensure that all gas cylinders contain enough gas.
• A demand flow regulator must be used with all gas
cylinder connections. Input pressure not to exceed 10 psi.
• Calibrate and bump test only in a safe area that is free of
hazardous gas.
• Do not expose the station to electrical shock or severe
continuous mechanical shock.
• The base station warranty will be void if the unit is
disassembled, adjusted, or serviced by non-BW
Technologies by Honeywell personnel.
• Ensure the exhaust line is not connected to a negative
pressure system.

MicroDock II
Quick Reference Guide
2
• Products may contain materials that are regulated for
transportation under domestic and international
dangerous goods regulations. Return product in
compliance with appropriate dangerous goods
regulations. Contact freight carrier for further
instructions.
• Do not replace detachable MAINS supply cords by
inadequately RATED cords.
• The external AC/DC power adapter must be supplied
with an approved cord suitable for the end use
installation.
Informations sur la sécurité - À lire avant
toute chose
Utiliser la station dans le seul but indiqué dans ce mémento.
Lire les Précautions suivantes avant d'utiliser la station.
a Précaution
• Si la station de base est endommagée ou s'il manque des
pièces, contactez immédiatement BW Technologies by
Honeywell.
• Vous pouvez être amené(e) à utiliser des gaz
potentiellement dangereux afin d'étalonner l'appareil. Aussi,
veillez toujours à effectuer cette opération dans une zone
bien aérée.
• La station doit être raccordée à un circuit d'aération ou
utilisée dans un local bien aéré.
• Ne pas immerger la station dans des liquides.
• La longueur maximale recommandée pour le tuyau
d'échappement est de 15,24 m (50 pi.).
• Vérifier que le filtre d'entrée est propre.
• Vérifier que toutes les bouteilles de gaz contiennent
suffisamment de gaz.
• Un régulateur de débit à la demande doit être utilisé avec
tous les raccords de bouteille de gaz. La pression d'entrée
ne doit pas dépasser 10 psi.
• Les opérations d'étalonnage et de test fonctionnel doivent
être exécutées dans une zone sûre, dépourvue de gaz
dangereux.
• Ne pas soumettre la station à des chocs électriques ni à
d'importants chocs mécaniques continus.
• La garantie de la station sera nulle si l'unité est démontée,
ajustée ou entretenue par du personnel étranger à BW

3
MicroDock II
Display Elements
Technologies by Honeywell.
• Vérifier que le tuyau d'échappement n'est pas raccordé à un
système à pression négative.
• Les produits peuvent contenir des matériaux qui sont
réglementés pour le transport en vertu des règlements
nationaux et internationaux de marchandises dangereuses.
Retourner le produit conformément à la réglementation sur
les marchandises dangereuses appropriées. Contactez
transporteur pour plus d'instructions.
• Ne pas remplacer les cordons détachables réseau
d'alimentation par des câbles mal notés.
• L'adaptateur d'alimentation externe AC / DC doit être fourni
avec un cordon homologué adapté pour l'installation de
l'utilisation finale.
Display Elements
Item Function
AC power
Batteries fully charged
Batteries half-charged
Batteries at low level
MultiMediaCard (MMC)
MultiMediaCard (MMC) not inserted
Test pass and option enabled
Test fail and option disabled
Cursor and sensor disabled
Scroll up
Scroll down
Selection arrow
Selected to be modified
Passcode protected

MicroDock II
Quick Reference Guide
4
Pushbuttons User Options Menu
Pushbutton Description
C
BUMP CHECK
To bump test a detector, press C
BUMP CHECK.
When connecting a new docking
module, press and hold
C BUMP CHECK to send a
confirmation signal back to the
base station.
C
CALIBRATION
To calibrate a detector, press
C CALIBRATION (all models
excluding GasAlertClip Extreme).
C
DATA TRANSFER
To transfer data from a detector,
press C DATA TRANSFER.
(GasAlert Extreme, GasAlertMi-
croClip / GasAlertMicroClip XT,
GasAlertMax XT / GasAlertMax
XT II, and GasAlertQuattro only).
The Automatic Datalog Down-
load option is available for the
GasAlertMicroClip / XT, GasAlert-
Max XT / II, and GasAlertQuattro
docking modules only. For more
information, refer to Data Trans-
fer.
Description Display
Time/Date modifies the time and
date of the base station.
Inlet Setup modifies the gas
type, the gas concentration lev-
els, and the gas cylinder lot num-
bers.
Pump Setup modifies the station
pump speed. Recommended
pump speeds are 60% (350 ml/
min.). The pump speed must be
set for each new docking mod-ule
that is added to the station.
NOTE: A flow meter is required.
Contrast brightens or dims the
text of the LCD.
Backlight enables/disables the
LCD backlight. When enabled,
the auto option automatically
deactivates the backlight when
the base station is not in use.

5
MicroDock II
Installation
Installation
Description Display
About displays the firmware
revision for the base station and
the docking module(s).
Format MMC formats the Mul-
tiMediaCard (MMC). NOTE:
This feature erases all current
data. Refer to the MicroDock II
User Manual.
Inlet Sel selects a gas inlet. If
auto is displayed, the base sta-
tion automatically selects the
correct inlet for the test.
Pass Code prevents unautho-
rized access to the menu
options. The LCD displays
when it is pass code protected.
Language displays all LCD
text in one of five languages:
Eng (English), Fran (French),
Deut (German), Port (Portu-
guese), and Espa (Spanish).

MicroDock II
Quick Reference Guide
6
a Warning
Use the base station in a fresh air environment. Do not
use the base station in a hazardous area.
All required National Electrical Codes (NEC) and safety
standards must be followed.
Note
The base station can operate from either an electrical
power source or batteries. The batteries will provide
automatic backup power if the main power fails.
1. Connect the power cord to the POWER port on the
base station, and then plug the cord into an AC outlet.
To install the batteries, refer to Battery Installation.
2. Connect the charger cord to the CHARGER port on
the base station first, and then plug the cord into an
AC outlet.
3. Attach all gas connections. Inlet 1 (PURGE) is config-
ured for ambient air and inlets 2-5 are configured for
calibration/test gases. Refer to Confirm Inlet Setup.
4. A demand flow regulator must be used with all gas
cylinder connections.
5. Ensure the exhaust line is not connected to a nega-
tive pressure system.
For AC main operation, the method to disconnect power is
to unplug the power cord from the outlet. A locking device
may not be used on the power cord plug.
Item Description
1 Inlet filter assembly
2 C-cell batteries (4)
3 Battery cover
4 Philips pan head retaining screws (2)
5 MultiMediaCard (MMC)
6 Battery compartment
7 Charger port
8 USB port
9 Power port
10 Exhaust outlet
11 Gas cylinder
12 Demand flow regulator
13 Calibration gas hose

7
MicroDock II
Inserting the Detector
Battery Installation
To install batteries in the base station, complete the following:
a Warning
Only install batteries in a fresh air environment. Do not
install batteries in a hazardous area. Failure to adhere to
this warning can result in personal injury and/or property
damage.
Use only alkaline C-size batteries; do not use
rechargeable batteries in the MicroDock II.
1. Loosen the retaining screws from the battery cover.
Do not remove the screws from the cover.
2. Remove the battery cover and insert four C-cell bat-
teries into the battery compartment.
3. Replace the battery cover and tighten the retaining
screws. Do not overtighten.
Mounting the MicroDock II Base Station and Docking
Modules
For wall mounting instructions, refer to the MicroDock II Base
Station User Manual.
Inserting the Detector
a Caution
Infrared or intense ambient light (sun or halogen) may
interfere with the base station/detector communication.
To insert a detector into a docking module, complete the follow-
ing:
1. Activate the detector and wait until it is in normal
operation.
2. Ensure the alligator clip is closed and the ring is rest-
ing flat on the detector.
3. Press the two release tabs on the docking module
and open the lid.
• If inserting the GasAlertMax XT / GasAlertMax
XT II, move the pump connector up.
4. Refer to the following sections to insert the detectors
into the docking modules.
GasAlertClip Extreme / GasAlert Extreme
• Lower the detector (serial number face up) into the
detector bay.
• Push forward to ensure the top of the detector connects
with the top of the bay.
• Close the lid and press until the release tabs click.
• When the detector has been inserted correctly, the RUN
LED(s) on the docking module light yellow and Unit
Inserted displays on the base station LCD. The base

MicroDock II
Quick Reference Guide
8
station LCD displays the docking module number, and
the type and serial number of the detector.
GasAlertMicro
• Insert the bottom of the detector (serial number face up)
into the detector bay first and then lower the top into
place.
• Close the lid and press until the release tabs click.
• When the detector has been inserted correctly, the RUN
LED(s) on the docking module light yellow and Unit
Inserted displays on the base station LCD. The base
station LCD displays the docking module number, and
the type and serial number of the detector.
GasAlertMicro 5/PID/IR
Important: If the GasAlertMicro 5/PID/IR detector is fitted with
a pump module, the diffusion adapter must be removed from
the docking module. Refer to the MicroDock II Base Station
User Manual.
• Insert the GasAlertMicro 5/PID/IR (LCD facing up) at a
45° angle and insert the bottom into the docking bay.
Ensure the connector outlets on the bottom of the detec-
tor lock into place over the connector pins in the docking
bay.
• Close the lid and press until the release tabs click.
• When the detector has been inserted correctly, the RUN
LEDs light yellow, Unit Inserted displays on the base
station LCD, and MicroDock displays on the detector
LCD. The base station LCD displays the docking mod-
ule number, and the type and serial number of the
detector.
GasAlertMicroClip / GasAlertMicroClip XT
Important: If the GasAlertMicroClip / GasAlertMicroClip XT is
fitted with a calibration cap or an auxiliary filter, it must be
removed prior to inserting it into the docking module. Refer to
the GasAlertMicroClip User Manual or GasAlertMicroClip XT
Technical Reference Guide and the MicroDock II Base Station
User Manual.
Note
The GasAlertMicroClip cannot be used in the
GasAlertMicroClip XT docking module and vice
versa.
• Insert the bottom of the detector (serial number face up)
at a 30° angle into the detector bay.
Note
The docking module lid only raises upward 30°. Do
not force the lid beyond its limit.
• Close the lid and press until the release tabs click.
• When the detector has been inserted correctly, the RUN
LEDs on the docking module light yellow and Unit
Inserted displays on the base station LCD. The base
Table of contents
Other Honeywell Test Equipment manuals

Honeywell
Honeywell TKA295 User manual

Honeywell
Honeywell POL-200-TS User manual

Honeywell
Honeywell Posi3 USB User manual

Honeywell
Honeywell S300RPTU User manual

Honeywell
Honeywell Vibrex 2000 User manual

Honeywell
Honeywell MicroDock II User manual

Honeywell
Honeywell IQ Force Dock User manual

Honeywell
Honeywell Enraf VITO 762 User manual

Honeywell
Honeywell TB7200 Series User manual

Honeywell
Honeywell HPBLT Technical manual