HGST Ultrastar Serv60+8 User manual

Contents
Revision History..............................................................................................4
Copyright........................................................................................................5
Chapter 1 Overview....................................................................................6
1.1 Ultrastar®Serv60+8 Description........................................................6
1.2 Ultrastar Serv60+8 Layout.................................................................7
1.3 Ultrastar Serv60+8 Specification Summary.......................................9
1.4 Ultrastar Serv60+8 Rack Requirements..........................................10
1.4.1 Compatible Hardware Configuration............................................12
1.5 List of Compatible Drives.................................................................13
Chapter 2 Disclaimers..............................................................................23
2.1 Restricted Access Location..............................................................23
2.2 Safety Compliance...........................................................................23
2.3 Electromagnetic Compatibility (EMC) Class A Compliance ............23
2.4 Country Certifications......................................................................24
Chapter 3 Safety.......................................................................................25
3.1 Electrostatic Discharge....................................................................25
3.2 Optimizing Location..........................................................................25
3.3 Power Connections..........................................................................25
3.4 Power Cords.....................................................................................26
3.5 Rackmountable Systems.................................................................26
3.6 Safety and Service...........................................................................26
3.7 Safety Warnings and Cautions.........................................................27
Chapter 4 Packaging................................................................................28
ii
Contents
Installation Guide

4.1 Ultrastar Serv60+8 Packaging Overview.........................................28
4.2 Ultrastar Serv60+8 Unpacking Procedure.......................................29
Chapter 5 Installation...............................................................................33
5.1 Ultrastar Serv60+8 Installation Overview.........................................33
5.2 Ultrastar Serv60+8 Installation Procedure.......................................33
Chapter 6 Points of Contact....................................................................52
iii
Contents
Installation Guide

Copyright
The following paragraph does not apply to the United Kingdom or any country where such provisions
are inconsistent with local law: HGST a Western Digital company PROVIDES THIS PUBLICATION "AS
IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. Some states do not allow disclaimer or express or implied warranties in certain transactions,
therefore, this statement may not apply to you.
This publication could include technical inaccuracies or typographical errors. Changes are periodically made
to the information herein; these changes will be incorporated in new editions of the publication. HGST may
make improvements or changes in any products or programs described in this publication at any time.
It is possible that this publication may contain reference to, or information about, HGST products (machines
andprograms),programming,orservicesthat are notannounced in yourcountry. Such referencesor information
must not be construed to mean that HGST intends to announce such HGST products, programming, or
services in your country.
Technical information about this product is available by contacting your local HGST representative or on the
Internet at: support.hgst.com
HGST may have patents or pending patent applications covering subject matter in this document. The furnishing
of this document does not give you any license to these patents.
©2017-2018 Western Digital Corporation or its affiliates.
Western Digital
5601 Great Oaks Parkway
San Jose, CA 95119
Long Live Data™is a trademark of HGST, Inc. and its affiliates in the United States and/or other countries.
HGST trademarks are authorized for use in countries and jurisdictions in which HGST has the right to use,
market and advertise the brands.
Other product names are trademarks or registered trademarks of their respective owners.
One MB is equal to one million bytes, one GB is equal to one billion bytes, one TB equals 1,000GB (one trillion
bytes) and one PB equals 1,000TB when referring to storage capacity. Usable capacity will vary from the raw
capacity due to object storage methodologies and other factors.
References in this publication to HGST products, programs or services do not imply that HGST intends to
make these available in all countries in which HGST operates.
Product information is provided for information purposes only and does not constitute a warranty.
Information is true as of the date of publication and is subject to change. Actual results may vary. This publication
is for general guidance only. Photographs may show design models.
5
Copyright
Installation Guide

Chapter
1
1 Overview
This section provides a high level overview of the features of the Ultrastar Serv60+8.
1.1 Ultrastar®Serv60+8 Description
Figure 1: Ultrastar Serv60+8
The Ultrastar®Serv60+8 is a 4U form factor, high density, rack-mounted storage enclosure that is capable
of hosting up to 60 HDD SAS or SATA drives. The maximum data storage capacity of the Ultrastar Serv60+8
is720TB using 12TB HGST Ultrastar®He12 HDDs plus an additional 61.44 TB using HGST Ultrastar®SS300
SSDs in the system SSD slots. (For a full list of compatible drives and total storage capacities, see the List
of Compatible Drives on page 13.) The Ultrastar Serv60+8 also integrates an Intel Skylake based server
front end. The server is built around an Intel Sawtooth Pass S2600ST motherboard and supports 2 LGA3647-0
(Socket P) processor sockets CPUs, 16 (8 per CPU) slots of DDR4 ECC DIMM memory, and leverages an
AST2500 BMC for out-of-band management of the server subsystem.The enclosure runs on an input voltage
of 200 - 240 VAC and consumes ~1800W of power under typical conditions. It requires a maximum of ~2000W
at full load.
Note: Max and Typical Power Consumption values represent the output power to the system. Input
power will vary depending on the PSU efficiency and load sharing between PSUs
The system contains three externally facing Half-Height, Half-Length (HHHL) PCIe x16 slots, and 3 externally
facing HHHL PCIe x8 slots.
It is designed to fit within a 4U rack space and requires 1200 mm (47.24in.) of usable rack space, frame to
frame. A fully loaded system will add 95.25 kg / 210 lbs. of static load when fully loaded with drives.
• 4U Storage Server
• Supports up to 60 HDD Drives
• Can support 3.5” drives and 2.5” SSD drives (2.5" requires an adapter) in the 60 available drive bays.
Supports an additional 8 2.5" drives in the system SSD slots located in the center channel
• Up to 12W per drive slot for the 60 HDD data storage drives (Cannot exceed 85A on the 5V rail) and 25W
per slot for the 8 system SSD slots
• House and control six (6) N+1 redundant 80mm fans
• Powered by two (2) redundant 2000W PSUs
• Toolless replacement of all Customer Replaceable Units (CRUs)
• Fits within a standard EIA-310 rack including all necessary cable management
• Supports Highline Input Power
6
1 Overview
Installation Guide 1.1 Ultrastar®Serv60+8 Description

• Dual Skylake LGA3647 Socket Processors
• 16 DDR4 ECC DIMM slots
• ASPEED AST2500 BMC
• Lewisburg PCH C624 Chipset
1.2 Ultrastar Serv60+8 Layout
Figure 2: Front and Rear Product Layout
Table 1: Front and Rear Component Identification
ComponentNumber
Enclosure Handles1
CMA2
PSUs3
Rear IO Ports4
Chassis Cover5
Rails6
7
1 Overview
Installation Guide 1.2 Ultrastar Serv60+8 Layout

The following is an image of the layout of the major system components inside the Ultrastar Serv60+8.
Figure 3: Component Layout
Figure 4: Rear IO Ports
8
1 Overview
Installation Guide 1.2 Ultrastar Serv60+8 Layout

1.3 Ultrastar Serv60+8 Specification Summary
Table 2: Environmental Specification Summary
OperationalNon-OperationalSpecication
5°C to 35°C-40°C to 70°CTemperature
20°C per hour maximum30°C per hour maximumTemperature Gradient
1°C per 300m above 900m1°C per 300m above 3000mTemperature De-rating
8-90% Non-Condensing8-90% Non-CondensingRelative Humidity
30% per hour maximum30% per hour maximumRelative Humidity Gradient
-300m to 3048m / -984 ft. to 10,000 ft.-300m to 12,000m / -984 ft. to 39,370 ftAltitude
Table 3: Electrical Specifications
ValueSpecication
~2000WMax Power Consumption
~1800WTypical Power Consumption
Note: Max and Typical Power Consumption
values represent the output power to the
system. Input power will vary depending on
thePSU efficiency and loadsharing between
PSUs
200 - 240 VACInput Voltage
C14PSU Connector Type
80 PLUS PlatinumPSU Efciency
AC line inrush current shall not exceed 35A peak
measured per IPC-9592B(L) Appendix C-4.1.
Inrush Current Maximum (per PSU)
15ATypical Inrush Current (per PSU)
Caution: The Ultrastar Serv60+8 can only be plugged into highline. If the unit is plugged into lowline,
the PSU will report a "Critical" state when status pages are queried using SES. In this case, the enclosure
will power up, but the drives will not.
Table 4: Mechanical Specifications
OperationalNon-OperationalSpecication
5G, 0 - peak, 11ms half sine; 3
positive and 3 negative pulses in each
10G, 0 - peak,11ms half sine; 3
positive and 3 negative pulses in each
axis shock
Shock
axis- minimum 6 seconds between
9
1 Overview
Installation Guide 1.3 Ultrastar Serv60+8 Specification Summary

OperationalNon-OperationalSpecication
shocks to allow for write/read
recovery
0.10G,0 - peak swept sine; 5 -500Hz;
1 complete sweep @ 1/2octave per
minute
0.75G, 0 - peak swept sine; 5 -500Hz;
1 complete sweep @ 1/2 octave per
minute
Vibration
95.25 kg / 210 lbs.Weight
W: 447mm x L: 1197 mm x H: 175mm / W: 17.6in. x L: 47.13in.. x H:
6.89in.
Dimensions with CMA
1026 mm / 40.39in.Length without CMA
450mm with (17.72in.) with 465mm (18.31in.) ± 1.5mm nominal hole
spacing. See EIA-310 Rack Standard
Required Rack Width
1200 mm (47.24in.) of usable rack space, frame to frameRequired Rack Depth
4URack Units (U)
32 in. - 36 in.Vertical Rack Rail Spacing
Table 5: Performance Specifications
ValueSpecication
Intel Sawtooth Pass S2600STMother Board
Intel SkylakeProcessor Type
LGA3647-0 (Socket P) processor socketsSocket
2Number of Processors
Lewisburg PCH C624 ChipsetChipset
DDR4 ECC DIMMMemory Type
16 (8 per CPU)Number of Memory Slots
IntegratedGraphics
AST2500Sever BMC Chip
60 HDD / 8 SSDNumber of Drive Slots
12Gbps SAS / 6Gbps SATAData Transfer Rates
720TB using 12TB HGST Ultrastar®He12 HDDs / 61.44
TB using HGST Ultrastar®SS300 SSDs
Max Raw Data Storage Capacity
1.4 Ultrastar Serv60+8 Rack Requirements
The Ultrastar Serv60+8 is designed to be installed into a rack that meets the EIA-310 standard at a minimum
1200 mm (47.24in.) of usable rack space, frame to frame. The vertical rack rails must be set between 32 in.
10
1 Overview
Installation Guide 1.4 Ultrastar Serv60+8 Rack Requirements
This manual suits for next models