READ THIS CAREFULLY BEFORE USING THIS DEVICE FOR THE FIRST TIME.
PAY ATTENTION: to avoid overheating, do not cover the appliance.

HYCD-1500T
2
SAFETY ADVICE
READ THIS NOTICE CAREFULLY BEFORE OPERATING THE APPLIANCE.
This product is not intended to be used by persons (including children) whose
physical, sensory or mental capacities are reduced or by persons without experience
or knowledge, unless if they have been given help, from someone responsible for
their safety, supervision or giving the instructions concerning the use of the device.
Make sure that the voltage indicated on the nameplate of the appliance corresponds
to that of your electrical installation. If this is not the case, contact your dealer and do
not connect.
Regularly check the condition of the power cable. Do not use if the power cord, plug
or appliance is damaged
The device should not be placed underneath a power outlet.
The power cable should never be in contact with hot parts of the device.
CAUTION: To prevent overheating, do not cover the heater.
Never immerse the appliance in water or other liquids.
Keep a minimum distance of one meter from flammable objects such as curtains,
textiles etc.
Do not clean the unit with abrasive chemicals.
Do not place sharp metal objects or your fingers into the unit to prevent damage and
reduce the risk of electric shock.
Do not use accessories other than those supplied or recommended by the
manufacturer. This can be dangerous and may damage the device.
Never repair the unit yourself. Otherwise you will lose the benefit of the guarantee.
Like any electrical appliance, it must be repaired by a qualified person. If the power
cable is damaged, it must be replaced by the manufacturer, his service agent or
similarly qualified person in order to avoid danger.
A repair involving the opening of the radiator can be made by the manufacturer or its
distribution network.
THE MANUFACTURER IS NOT RESPONSIBLE FOR THE MISUSE OF THE EQUIPMENT.
KEEP THESE INSTRUCTIONS CAREFULLY FOR FUTURE REFERENCE.

HYCD-1500T
3
1 / SPECIFICATIONS
Digital LCD display
Temperature control by digital display
Clock
Weekly schedule
2 modes :
oManual
oAutomatic with weekly presetting
- 24h programmer, custom setting.
- 9 different daily presets
Frost protection function - automatically switches on if temperature drops below 7°
to protect pipes from frost
Model
Power
Voltage
Number of
elements
Insulation
class
Heat Design –E600
600W
AC 230 50Hz
4
Class II
Heat Design –E900
900W
AC 230 50Hz
6
Class II
Heat Design –E1200
1200W
AC 230 50Hz
8
Class II
Heat Design –E1500
1500W
AC 230 50Hz
10
Class II
Heat Design –E1800
1800W
AC 230 50Hz
12
Class II
ONLY FOR USE INDOORS
Replacing the Plug
If the Plug is damaged or requires replacement, follow the wiring instructions supplied with
the new Plug.
The Green and Yellow wire must be connected to the terminal marked with the Earth symbol
or coloured Green & Yellow.
The Brown wire must be connected to the terminal marked with the letter L or coloured Red.
The Blue wire must be connected to the terminal marker with the letter N or coloured Black.
A 13amp Plug to BS 1363 must be fitted with a 13amp fuse to BS 1362.

HYCD-1500T
4
How to install the device
Make sure that the distance from walls and objects is respected.
Figure 1a
1 –Drill holes in the wall by following the steps in Figure 1. Make sure they are all correct.
Distance L and M between the fixation points.
Radiator
900W
1500W
1800W
L (mm)
400
560
720
M (mm)
320
480
640

HYCD-1500T
5
Figure 1b
2 - Place all the Rawl plugs in the holes in the wall, as in the previous step
3 - Attach the upper brackets using screws
4 - Place the radiator on the brackets
5 –Attach the lower brackets with screws and place the radiator to the wall
Warning: Before plugging in the unit make sure the radiator is properly attached to the
wall. Otherwise problems can occur.
2 / DESCRIPTION
2.1 / the Control Panel
-On / off
+ - Hold both buttons for 3 Seconds to lock or unlock control panel
- setting time, day and temperature

HYCD-1500T
6
- Mode selection and programs
- Increase of the selected criterion
- Decrease of the selected criterion
2.2 / LCD display
1 - Hour
2 - Day
3 - Program number
4 - Programmed temperature
5 - Comfort mode
6 - Economic mode
7 - Frost mode
8 - Sleeping mode
9 - Locking radiator
10 - Heating on
11 - Select program
12 - Timer
13 - Program content
14 -Time scale
2.3 / Operating instructions
The radiator has three different operating Modes.
1. A free operating mode with running timer.
2. A daily program mode including 9 different programs from to combining
two operating modes : comfort , economic and frost .
3. A weekly program mode : assigning a daily schedule for every day of the week

HYCD-1500T
7
3 / FREE OPERATING MODE
3.1 –Use :
Connect the unit to the mains, press the power switch on the back of the unit.
Press , the icon disappears. The device is now running free . Preset
temperature of 10°C.
.
3.2 –Adjustment of day and time :
Press once , the hours are flashing, then use the buttons
and to adjust the hours,
Press again , the minutes are flashing, then use the
buttons and to adjust the minutes,
Press again , the date is flashing, then use the buttons and
to select the day : 1- Monday, 2 –Tuesday, 3 –Wednesday, 4
–Thursday, 5 –Friday, 6 –Saturday, 7 –Sunday.
Press once more to confirm your choice.

HYCD-1500T
8
3.3 –Temperature setting
Press once or . The temperature display flashes. Press again or to adjust
the desired temperature. (the temperature can be set over a range of 10ºC to 35ºC).
After 5 seconds without action on buttons or , the temperature is validated.
3.4 –How to use the timer
Press for 3 seconds, the icon appears. At the same time the hour display flashes
and will pass at 00:00.
Using the buttons and choose the operating time in steps of 30 minutes. After 5
seconds without action on the buttons or , the duration is validated.
Once the timer duration has lapsed, the radiator will automatically go into standby .
Note : To exit the timer mode, press 3 seconds .The radiator returns to free operating
mode .
4 / HOW TO USE THE DIFFERENT PROGRAMS :
4.1 –Selection of the operating mode
; weekly program
~, daily program that repeats itself every day
; free operating mode.

HYCD-1500T
9
Increase or decrease the temperature by using or
1- Press once .
2- Choose , , ~by using or .
3- Press once to confirm your choice
NOTE : If after selecting the program, no button on the keyboard is activated for 5 seconds,
the selection is confirmed automatically.
4.2 –Daily program :
The radiator has 9 daily programs ranging from to .
Each segment, representing a time of day, can be assigned to the operating mode:
for comfort ,
for economic
for frost
The nine programs have been preset at the factory as follows:
for comfort , temperature of 22ºC
for economic , temperature of 17ºC
for frost , temperature of 7ºC (this mode cannot be personalised !)

HYCD-1500T
10
4.3 –Personalisation of the operating modes comfort and economic :
1- Press for 3 seconds, the icon flashes and also the temperature indicator.
2- Use , to adjust the desired temperature for the comfort mode.
3- Press to confirm your selection, the icon flashes and also the temperature
indicator.
4- Use , to adjust the desired temperature for the economic mode.
5- Press to confirm your selection.
6- The radiator automatically returns to comfort mode .
NOTE : If after selecting the program, no button on the keyboard is activated for 5 seconds,
the selection is confirmed automatically.
This manual suits for next models