HBM C11 Series User manual

Mounting Instructions | Montageanleitung |
Notice de montage
English Deutsch Français
C11

Hottinger Brüel & Kjaer GmbH
Im Tiefen See 45
D-64293 Darmstadt
Tel. +49 6151 803-0
Fax +49 6151 803-9100
www.hbm.com
Mat.: 7-0111.0008
DVS: A05449_01_Y00_02 HBM: public
06.2021
EHottinger Baldwin Messtechnik
Subject to modifications.
All product descriptions are for general information only.
They are not to be understood as a guarantee of quality or
durability.
Änderungen vorbehalten.
Alle Angaben beschreiben unsere Produkte in allgemeiner
Form. Sie stellen keine Beschaffenheits- oder Haltbarkeits
garantie dar.
Sous réserve de modifications.
Les caractéristiques indiquées ne décrivent nos produits
que sous une forme générale. Elles n'impliquent aucune
garantie de qualité ou de durabilité.

Mounting Instructions | Montageanleitung |
Notice de montage
English Deutsch Français
C11

2A05449_01_Y00_02 HBM: public C11
English
1 Safety instructions 3........................................
2 Markings used 7............................................
2.1 The markings used in this document 7..........................
3 Scope of supply and equipment variants 8...................
4 General instructions for use 9...............................
5 Structure and mode of operation 10...........................
5.1 Transducer 10................................................
5.2 Strain gage covering agent 10..................................
6 Conditions on site 11........................................
6.1 Ambient temperature 11.......................................
6.2 Moisture and corrosion protection 11............................
6.3 Deposits 12..................................................
7 Mechanical installation 13....................................
7.1 Important precautions during installation 13......................
7.2 General installation guidelines 13...............................
8 Electrical connection 15......................................
8.1 EMC protection 16............................................
9 Ordering numbers 17........................................
10 Specifications 18............................................
11 Dimensions in mm 20........................................

Safety instructions
C11 A05449_01_Y00_02 HBM: public 3
1 Safety instructions
Intended use
Force transducers in the C11 series are designed solely for measuring static
and dynamic compressive forces within the load limits stated in the
specifications. Any other use is not the intended use.
To ensure safe operation, it is essential to comply with the regulations in the
mounting instructions, the safety requirements listed below, and the data
specified in the supplied technical data sheets. It is also essential to observe
the applicable legal and safety regulations for the relevant application.
Force transducers are not intended for use as safety components. Please also
refer to the "Additional safety precautions" section. Proper and safe operation
of force transducers requires proper transportation, correct storage, setup and
mounting, and careful operation.
Load-carrying capacity limits
The information in the technical data sheets must be observed when using the
force transducers. The respective specified maximum loads in particular must
never be exceeded. The following limits set out in the technical data sheets
must not be exceeded:
SForce limits
SBreaking forces
SPermissible dynamic loads
STemperature limits
SElectrical load limits
Please note that when several force transducers are interconnected, the load/
force distribution is not always uniform.
Use as machine elements
Force transducers can be used as machine elements. When used in this man
ner, note that to favor greater sensitivity, force transducers were not designed
with the safety factors usual in mechanical engineering. Please refer to the
"Load-carrying capacities" section and to the specifications on page 18.

Safety instructions
4A05449_01_Y00_02 HBM: public C11
Accident prevention
The prevailing accident prevention regulations must be taken into account,
even though the nominal (rated) force values in the destructive range are well
in excess of the full scale value.
Additional safety precautions
Force transducers cannot (as passive transducers) implement any (safety-
relevant) cutoffs. This requires additional components and constructive
measures, for which the installer and operator of the plant is responsible.
In cases where a breakage or malfunction of the force transducer would cause
injury to persons or damage to equipment, the user must take appropriate
additional safety precautions that meet at least the applicable safety and
accident prevention regulations (e.g. automatic emergency shutdown, overload
protection, catch straps or chains, or other fall protection).
The electronic processor that processes the measurement signal should be
designed so that failure of the measurement signal cannot lead to secondary
failures.
General dangers of failing to follow the safety instructions
Force transducers are state-of-the-art and failsafe. Transducers can give rise
to residual dangers if they are mounted, installed, used and operated
inappropriately or by untrained personnel. Every person involved with setting
up, starting up, operating or repairing a force transducer must have read and
understood the mounting instructions and in particular the technical safety
instructions. The force transducers can be damaged or destroyed by non-
designated use of the force transducer or by non-compliance with the mounting
and operating manual, these safety instructions or other applicable safety
regulations (safety and accident prevention regulations of the Employers'
Liability Insurance Association) when using the force transducers. A force
transducer can break, particularly if it is overloaded. The breakage of a force
transducer can cause damage to property or injury to persons in the vicinity of
the force transducer.
If force transducers are not used as intended, or if the safety instructions or
specifications in the mounting and operating instructions are ignored, it is also
possible that a force transducer may fail or malfunction, with the result that

Safety instructions
C11 A05449_01_Y00_02 HBM: public 5
persons may be injured or property damaged (due to the loads acting on or
being monitored by the force transducer).
The scope of supply and performance of the transducer covers only a small
area of force measurement technology, as measurements with (resistive) strain
gage sensors presuppose the use of electronic signal processing. Equipment
planners, installers and operators should always plan, implement and respond
to the safety engineering considerations of force measurement technology in
such a way as to minimize residual dangers. Pertinent national and local
regulations must be complied with.
Conversions and modifications
The design or safety engineering of the transducer must not be modified with
out our express permission. Any modification shall exclude all liability on our
part for any damage resulting therefrom.
Maintenance
The force transducers of the C11 series are maintenance free. We recommend
to calibrate the force transducer at regular intervals.
Disposal
In accordance with national and local environmental protection and material
recovery and recycling regulations, old transducers that can no longer be used
must be disposed of separately and not with normal household garbage.
If you require more information about disposal, please contact your local
authorities or the dealer from whom you purchased the product.
Qualified personnel
Qualified personnel means persons entrusted with installing, mounting, starting
up and operating the product who possess the appropriate qualifications for
their work.
This includes people who meet at least one of these three requirements:
SKnowledge of the safety concepts of automation technology is a require
ment and as project personnel, you must be familiar with these concepts.

Safety instructions
6A05449_01_Y00_02 HBM: public C11
SAs automation plant operating personnel, you have been instructed how to
handle the machinery. You are familiar with the operation of the equipment
and technologies described in this documentation.
SAs commissioning engineers or service engineers, you have successfully
completed the training to repair the automation systems. Moreover, you are
authorized to start up, ground and label circuits and equipment in
accordance with safety engineering standards.
During use, compliance with the legal and safety requirements for the relevant
application is also essential. The same applies to the use of accessories.
The force transducer may only be installed by qualified personnel, strictly in
accordance with the specifications and with the safety requirements and
regulations.

Markings used
C11 A05449_01_Y00_02 HBM: public 7
2 Markings used
2.1 The markings used in this document
Important instructions for your safety are highlighted. It is essential to follow
these instructions to prevent accidents and damage to property.
Symbol Meaning
WARNING This marking warns of a potentially dangerous situa
tion in which failure to comply with safety require
ments may result in death or serious physical injury.
CAUTION This marking warns of a potentially dangerous
situation in which failure to comply with safety
requirements may result in minor to moderate
physical injury.
Notice This marking draws your attention to a situation in
which failure to comply with safety requirements may
result in damage to property.
Important
This marking draws your attention to important
information about the product or about handling the
product.
Tip
This marking indicates tips for use or other
information that is useful to you.
Information
This marking draws your attention to information
about the product or about handling the product.
Emphasis
See …
Italics are used to emphasize and highlight text and
identify references to chapters, diagrams, or external
documents and files.

Scope of supply and equipment variants
8A05449_01_Y00_02 HBM: public C11
3 Scope of supply and equipment variants
SC11 force transducer
SC11 installation instructions
STest record
This manual suits for next models
6
Table of contents
Languages:
Other HBM Transducer manuals
Popular Transducer manuals by other brands

ProMinent
ProMinent Dulcometer DMT operating instructions

MKS
MKS MicroPirani 925 Series Short form manual

WIKA
WIKA WU-20 operating instructions

Alcatel Vacuum Technology
Alcatel Vacuum Technology BARATRON 622A instruction manual

Camille Bauer
Camille Bauer SIRAX CH-5610 operating instructions

WIKA
WIKA F2802 operating instructions

Veris Industries
Veris Industries PW Series installation guide

Simrad
Simrad ES120-7C - REV D Dimensions

Airmar
Airmar M260 Owner's guide & installation instructions

Spirax Sarco
Spirax Sarco ITV1030 Installation and maintenance instructions

halstrup-walcher
halstrup-walcher PU10 instruction manual

Balluff
Balluff BTL5-P user guide