HBM ME50S6 User manual

Operating Manual | Bedienungsanleitung |
Manuel d'emploi
English Deutsch Français
ME50S6

Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45
D-64293 Darmstadt
Tel. +49 6151 803-0
Fax +49 6151 803-9100
www.hbm.com
Mat.: 7-2002.0380
DVS: A00260_04_Y00_01 HBM: public
12.2018
EHottinger Baldwin Messtechnik GmbH.
Subject to modifications.
All product descriptions are for general information only.
They are not to be understood as a guarantee of quality or
durability.
Änderungen vorbehalten.
Alle Angaben beschreiben unsere Produkte in allgemeiner
Form. Sie stellen keine Beschaffenheits- oder Haltbarkeits
garantie dar.
Sous réserve de modifications.
Les caractéristiques indiquées ne décrivent nos produits
que sous une forme générale. Elles n'impliquent aucune
garantie de qualité ou de durabilité.

Operating Manual | Bedienungsanleitung |
Manuel d'emploi
English Deutsch Français
ME50S6

2A00260_04_Y00_01 HBM: public ME50S6
English
1 Safety instructions 4........................................
2 Markings used 6............................................
2.1 The markings used in this document 6..........................
2.2 Symbols on the product 7.....................................
3 Measuring Amplifiers on Eurocards ME50S6 8................
4 Electrical Connection 9.....................................
4.1 Transducer Connection 9.....................................
4.2 Supply Voltage 10............................................
4.3 Output 10....................................................
4.4 Pin Assignment 11............................................
5 Putting into Operation 12....................................
5.1 Select Measuring Range 12....................................
5.2 Bridge Zero Balancing 12......................................
5.3 MR Fine Adjustment 12........................................
6 Individual Settings 14........................................
6.1 Operational Setting 14.........................................
6.2 Setting the Measuring Range 14................................
6.3 External Fine Balancing of the MR1 15..........................
6.4 Bridge Fine Balancing 16......................................
6.5 Calibration Signal 16..........................................
6.6 Measuring Frequency Range / Cut‐off Frequency fco 17...........
6.7 Synchronization 17............................................
7 Options 18..................................................
7.1 Stabilized Power Supply 18....................................
7.2 DC‐DC Converter 18..........................................
7.3 Current Output Module 19.....................................
7.4 Safety Barriers for use in Hazardous Areas 19....................

Safety instructions
4A00260_04_Y00_01 HBM: public ME50S6
1 Safety instructions
In order to ensure sufficient immunity from disturbance only use Greenline
shielding (see HBM's special publication ”Greenline” Screening Concept, elec
tromagnetic compatibility of measuring cable, downloadable from the Internet
at http://www.hbm.com/Greenline).
The connection lines' (≤50 V) minimum insulation strength must be 350 V (AC).
Appropriate use
The ME50S6 with the connected transducers may be used for measurement
and directly related control and regulation tasks, only. Any other use is not ap
propriate.
To ensure safe operation, the ME50S6 may only be used according to the
specifications given in this manual. When using the transducer, the legal and
safety regulations for the respective application must also be observed. The
same applies if accessories are used.
General dangers in the case of non‐observance of the safety instructions
The ME50S6 complies with the state of the art and is operationally reliable. If
the device is used and operated inappropriately by untrained personnel, resid
ual dangers might develop.
Any person charged with device installation, operation, maintenance or repair
must in any case have read and understood the operating manual and the
safety instructions, in particular.
Conditions on site
Protect the device from moisture or atmospheric influences such as rain, snow,
etc.

Safety instructions
ME50S6 A00260_04_Y00_01 HBM: public 5
Maintenance and cleaning
The Clip Electronic are maintenance‐free. Please note the following points
when cleaning the front panel:
SRemove the mains plug from the socket before cleaning.
SClean the front panel with a soft, slightly damp (not wet!) cloth. Never use
solvents, since they may damage the labelling on the front panel.
SWhen cleaning, please ensure that no liquid finds its way into the device or
onto the contacts.
Residual dangers
The ME50S6 scope of performance and supply covers part of the measuring‐
technology, only. The plant designer/constructor/operator must in addition de
sign, realise and take responsibility for the measuring‐system's safety such
that potential residual dangers are minimized. The respective regulations must
in any case be observed. Residual dangers regarding the measuring system
must be specified explicitly.
Reconstruction and modifications
HBM's express consent is required for modifications regarding the ME10
construction and safety. HBM does not take responsibility for damage resulting
from unauthorized modifications.
In particular, repair and soldering works on the boards are prohibited. If com
plete componentry is replaced use original HBM components, only.
Qualified personnel
The device may be used by qualified personnel, only; the technical data and
the special safety regulations must in any case be observed. When using the
device, the legal and safety regulations for the respective application must also
be observed. The same applies if accessories are used.
Qualified personnel means: personnel familiar with the installation, mounting,
start‐up and operation of the product, and trained according to their job.
Maintenance and repair work on an open device with the power on should only
be undertaken by trained personnel who are aware of the above‐mentioned
dangers.

Markings used
6A00260_04_Y00_01 HBM: public ME50S6
2 Markings used
2.1 The markings used in this document
Important instructions for your safety are specifically identified. It is essential to
follow these instructions in order to prevent accidents and damage to property.
Symbol Significance
WARNING This marking warns of a potentially dangerous
situation in which failure to comply with safety
requirements can result in death or serious physical
injury.
CAUTION This marking warns of a potentially dangerous
situation in which failure to comply with safety
requirements can result in slight or moderate physical
injury.
Notice This marking draws your attention to a situation in
which failure to comply with safety requirements can
lead to damage to property.
Important
This marking draws your attention to important
information about the product or about handling the
product.
Tip
This marking indicates application tips or other
information that is useful to you.
Information
This marking draws your attention to information
about the product or about handling the product.
Emphasis
See….
Italics are used to emphasize and highlight text and
references to other chapters and external documents.

Markings used
ME50S6 A00260_04_Y00_01 HBM: public 7
2.2 Symbols on the product
CE mark
The CE mark enables the manufacturer to guarantee that
the product complies with the requirements of the rele
vant EC directives (the declaration of conformity is avail
able at http://www.hbm.com/HBMdoc).
Statutory marking requirements for waste disposal
National and local regulations regarding the protection of
the environment and recycling of raw materials require
old equipment to be separated from regular domestic
waste for disposal.
For more detailed information on disposal, please contact
the local authorities or the dealer from whom you pur
chased the product.

Measuring Amplifiers on Eurocards ME50S6
8A00260_04_Y00_01 HBM: public ME50S6
3 Measuring Amplifiers on Eurocards ME50S6
The Eurocards ME50S6 are 4.8KHz carrier frequency measuring
single‐channel amplifiers for strain gauge transducers.
All plug‐in cards are delivered without housing or rack frame and without power
supply unit so that an individual setting in an existing 19” rack mounting system
is possible. Owing to the narrow width of the plug‐in cards (4 divs = 20.32mm)
up to 21 cards can be inserted into a 19” rack. The dimensions and connecting
details correspond to the IEC standards 48D and 297.
All controls necessary for easy operation are accessible from the front.
Individual adjustments are described in chapter four; factory settings are speci
fied on the back of the Eurocard.