Happy Cocooning SR2201BI/I2 Plus Product information sheet

BUILT-IN GAS FIRE BURNER KIT
ASSEMBLY INSTRUCTIONS AND SAFETY GUIDE
U
10BUSR2201BI/I2+, SRR2201BI/I2+ &
SR4001BIS/I2+, SR4001BIR/I2+
0063/YY
SR2201BI/I2+ &SRR2201BI/I2+ Preferential ΣQn(Hs)= 6.5 kW, 473 g/h I3+(28-30/37), I3 B/P(30), I3 B/P(50),
I2L & I2H/I2E/I2E+
SR4001BIS/I2+ & SR4001BIR/I2+ Preferential ΣQn(Hs)= 12 kW, 873 g/h I3+(28-30/37), I3 B/P(30), I3 B/P(50)
& I2L
SR4001BIS/I2+ & SR4001BIR/I2+ Preferential ΣQn(Hs)= 13 kW, 946 g/h I2H/I2E/I2E+
BE, CY, CZ, EE, GR, IT, IE, PT, ES, LU, GB, FR, IS, LT, PT, SK, CH: Cat. I3+ Butane(G30)=28~30 mbar,
Propane(G31)=37mbar, Injector SR2201BI/I2+ & SRR2201BI/I2+:1.2 mm SR4001BIS/I2+ & SR4001BIR/I2+:
1.65mm
CY, CZ, DK, EE, FI, GR, LV, LT, LU, MT, NL, NO, SK, SI, SE, TR, HU: Cat. I3 B/P(30)=Butane, propane or
their mixture at 30mbar, Injector SR2201BI/I2+ & SRR2201BI/I2+: 1.2 mm SR4001BIS/I2+ &
SR4001BIR/I2+:1.65mm
AT, DE, SK, CH: Cat. I3 B/P(50)= Butane, propane or their mixture at 50mbar, Injector SR2201BI/I2+ &
SRR2201BI/I2+: 1.02mm SR4001BIS/I2+ & SR4001BIR/I2+: 1.45mm
AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU, IE, IT, LT, LU, LV, NL, NO, PL, PT, RO, SE, SI, SK: Cat.
I2L Natural Gas(G25) at 25mbar, Injector SR2201BII2+ & SRR2201BII2+: 1.95mm SR4001BISI2+,
SR4001BIRI2+: 3.0mm and I2H/I2E/I2E+ Natural Gas(G20) at 20mbar, Injector SR2201BII2+ & SRR2201BII2+:
1.72mm SR4001BISI2+ & SR4001BIRI2+: 3.0mm
“ Only nationally approved hose and regulator corresponding to the appliance category and pressure
must be used ”
This manual is for:
PIN NO.: 0063CO7314
FOR OUTDOOR USE ONLY
Read the instructions before using the appliance. Keep the instructions for future reference.
Warning: Accessible parts may be very hot, keep young children away.

1
ASSEMBLY AND USER INSTRUCTIONS
FOR
OUTDOOR BUILT-IN GAS FIRE BURNER KIT
Your new SR2201BI/I2+, SRR2201BI/I2+ & 4001BIS/I2+, SR4001BIR/I2+ BUILT-IN GAS FIRE
BURNER KIT is made from the highest quality materials, and produced under strict manufacturing
controls.
Please read the Instructions for assembly before commencing, and follow the instructions for use
carefully. We congratulate you on your decision to buy this outdoor built-in gas fire burner kit and wish
you great fun when warming with it.
PLEASE READ THESE SAFETY INSTRUCTIONS
IN FULL BEFORE COMMENCING ASSEMBLY.
Important Safety instructions
The built-in gas fire burner kit is safe and easy to use. The following rules must be followed.
1. Ensure that the unit has been assembled correctly according to the instructions.
2. Never loosen, or allow the gas connection to become loose. Should this happen,
immediately ensure that the gas is turned off at the cylinder or main shut off valve of city
network gas, and then re-check the security of the connection.
3. The appliance shall be kept away from flammable materials.
4. Read the Users instruction, Sections, and instructions written on the built-in gas fire burner
kit, refer to them whenever necessary.
5. Never leave the built-in gas fire burner kit unattended while using.
6. In the event of a gas leak, the appliance shall not be used or if alight, turn off gas supply at
the LPG cylinder or the nearest main shut off valve of city network gas. And the appliance
shall be investigated and rectified before it is used again.
7. Keep children well clear while built-in gas fire burner kit is in use and after use until it has
cooled.
8. Keep warming area, 1m away from the appliance, clear of combustible materials and/or
liquids.
9. Never obstruct free flow of air to the built-in gas fire burner kit, or alter/adapt the built-in gas
fire burner kit to suit any other situation.
10. SR/R2201BI & SR4001BIS/R: A hose conforming to the national standard must be
connected at one end to the LPG regulator and at the other to the fire pit nipple using hose
clips. The hose length is 1m.
SR/R2201BII2+ & SR4001BIS/R/I2+: A hose conforming to the national standard must be
connected at one end to the main shut off valve of city network gas and at the other to the
fire pit inlet with a national standard NG connector. For the hose exposed, please be sure to
use (a) rubber/PVC layer(s) to cover on it to prevent people from stumbling. The proper
rubber/PVC layers are available from the same dealer or qualified installer.
The material of any description should not be thrown on to the fuel bed.
The appliance should not be used in bathroom or bedrooms.
The appliance is only intended to be used as secondary heating.

2
Unless a dress guard is fitted, this appliance shall be installed with a hearth that projects at
least 300 mm in front of the naked flame/incandescent fuel bed, extends at least 150 mm at
either side, and around its periphery is a height of at least 50 mm above finished floor level.
11. Lead the hose away from the built-in gas fire burner kit without twisting it. Do not let the
hose touch the hot surface.
12. Never change the air valve settings of the burner.
13. Every time the gas connection is reconnected do a leak test.
14. Those parts sealed by the manufacturer or the agent must not be altered by the user.
15. Any modification of this built-in gas fire burner kit may be dangerous.
16. Do not move this built-in gas fire burner kit during use.
17. Turn off the gas supply at the cylinder or main shut off valve of city network gas after use.
18. Do not touch the logs or lava rocks until they cool down.
19. This appliance is intended for warming purposes.
20. This appliance has a naked flame, a suitable guard should be used for the protection of
young children, the elderly and the infirm. IT DOES NOT GIVE FULL PROTECTION FOR
YOUNG CHILDREN OR THE INFIRM. It is advisable to fit the dress guard available from
the same dealer or qualified installer. Failure to fit this dress guard will result in a potential
hazard to clothing when approaching the appliance. The dress guard is not supplied with
the appliance, the installer shall inform the user of the local rules in force and advise the
fitting of the same dealer’s or qualified installer’s dress guard. He shall also warn the user of
the hazard caused to clothing by open flames if the dress guard is not fitted.
Recommendation: for any additional guard that may be required for the protection of
young children, aged or infirm persons. The minimum distance should be 10mm between
the appliance to any ventilation grille.
21. When first use, preheat the lava rocks and logs for 15 minutes to burn out the impurities
and air in the natural lava rocks and handmade logs.
22. To change the gas cylinder in an amply ventilated area, away from any ignition source
(candle, cigarettes, other flame producing appliances).
23. This appliance must be installed and the gas cylinder stored in accordance with the national
regulations in force.
24. Shut off the valve at the gas cylinder or the regulator before moving the appliance.
25. Use only the type of gas and the type of cylinder specified by the manufacturer.
13BContents
14B1. Technical Data
15BPage 3-3
16B2. Instructions for assembly
17BPage 4-14
18B3. Installation and operation instructions
19BPage 15-19
20B4. Maintenance
21BPage 20-21
The built-in gas fire burner kit is an I3+(28-30/37), I3 B/P(30), I3 B/P(50), I2L(G25) &
I2H/I2E/I2E+(G20) appliance, designed to operate on Butane at 28/30mbar, Propane 37mbar,
B/P 30/50mbar, I2L at 25mbar & I2H/I2E/I2E+ at 20mbar. Gas consumption, pressures and
injectors orifices sizes are shown below:

3
SR2201BI/I2+ & SRR2201BI/I2+ BUILT-IN GAS FIRE BURNER KIT
SR2201BI &
SRR2201BI
Injector Orifice
Heat Input(Hs)
Gas Rate
I3+(28-30/37), I3B/P(30)
1.2mm
6.5 kW
473 g/h
I3 B/P(50)
1.02mm
6.5 kW
473 g/h
SR2201BII2+ &
SRR2201BII2+
I2L
1.95mm
6.5 kW
473 g/h
I2H/I2E/I2E+
1.72mm
6.5 kW
473 g/h
SR4001BIS/I2+ & SR4001BIR/I2+ BUILT-IN GAS FIRE BURNER KIT
SR4001BIS &
SR4001BIR
Injector Orifice
Heat Input(Hs)
Gas Rate
I3+(28-30/37), I3B/P(30)
1.65mm
12 kW
873 g/h
I3 B/P(50)
1.45mm
12 kW
873 g/h
SR4001BISI2+
&SR4001BIRI2+
I2L
3.0mm
12 kW
873 g/h
I2H/I2E/I2E+
3.0mm
13 kW
946 g/h
The marking on the injector, for example, “1. 20” indicates that the size of injector is 1.20mm.
LP Gas Regulator
A gas regulator confirming to the national standard must be fitted to the gas cylinder to provide
the appropriate gas pressure.
The outlet pressure of the LPG regulator must comply with the table below:
I3B/P(30)
I3B/P(50)
I3+
LPG
LPG
Butane
Propane
28~30mbar
50mbar
28~30mbar
37mbar
Do Not use this appliance with an adjustable regulator. We suggest use this appliance with LP
gas cylinder of 5KG. Cylinder’s maximum height 70cm and maximum width 60cm
Instructions for assembly
Read these instructions through carefully before commencing assembly, and then follow them
step-by-step.

4
SR2201BI/I2+ - parts list & SRR2201BI/I2+ - parts list
No.
Description
Q’TY
No.
Description
Q’TY
01
Knob
1
22
Lava rock, 2KG
1
02
Valve
1
23
Log set
4
03
SS flexible tube
1
24
Nut M6
8
04
Injector, Main
1
25
Screw M5F17
2
05
Igniter needle with wire
1
26
Nut M5
2
06
Burner bowl
1
27
Screw M4F08
4
07
Fix plank, Burner head
2
28
Control panel
1
08
Pilot Igniter
1
29
Plate, Control panel
1
09
Burner head
1
30
Bracket, Burner Bowl
1
10
Leakage Protector
1
31
Frame
1
11
Windpipe
1
32
Screw M4F07
4
12
Nut, Pilot Igniter
1
33
Nut M4
4
13
Washer
1
34
Screw M6F41
2
14
Spring
1
35
Screw M6F10
2
15
Support plank, Igniter box
1
36
Lid
1
16
Injector, Pilot Flame
1
37
Table Support Bracket Kit
2
17
Copper tube, Pilot Flame
1
18
Thermocouple
1
19
Pulse battery box
1
20
Gas Inlet fitting
1
21
Igniter box
1
Note: The part No. 37 is an optional accessory, available from the same
dealer or qualified installer.

5
SR4001BIS/I2+ & SR4001BIR/I2+ - parts list
No.
Description
Q’TY
No.
Description
Q’TY
01
Knob
1
22
Lava rock, 3.5KG
1
02
Valve
1
23
Log set
5
03
SS flexible tube
1
24
Nut M6
8
04
Injector, Main
1
25
Screw M5F17
2
05
Igniter needle with wire
1
26
Nut M5
2
06
Burner bowl
1
27
Screw M4F08
4
07
Fix plank, Burner head
2
28
Control panel
1
08
Pilot Igniter
1
29
Plate, Control panel
1
09
Burner head
1
30
Bracket, Burner Bowl
1
10
Leakage Protector
1
31
Frame
1
11
Windpipe
1
32
Screw M4F07
4
12
Nut, Pilot Igniter
1
33
Nut M4
4
13
Washer
1
34
Screw M6F41
2
14
Spring
1
35
Screw M6F10
2
15
Support plank, Igniter box
1
36
Lid
1
16
Injector, Pilot Flame
1
37
Table Support Bracket Kit
2
17
Copper tube, Pilot Flame
1
18
Thermocouple
1
19
Pulse battery box
1
20
Gas Inlet fitting
1
21
Igniter box
1
Note: The part No. 37 is an optional accessory, available from the same
dealer or qualified installer.

6
SR2201BI/I2+ & SR4001BIS/I2+ series- exploded

7
SRR2201BI/I2+ & SR4001BIR/I2+ series- exploded

8
ASSEMBLY INSTRUCTIONS
GAS HOSE CONNECTIONS
SR2201BI, SRR2201BI & SR4001BIS, SR4001BIR: Attach the hose to the manifold inlet nipple
and tighten hose clip, or secure the hose to the manifold inlet fitting as shown in FIG.01 &
FIG.02 below.
SR2201BII2+, SRR2201BII2+ & SR4001BISI2+, SR4001BIRI2+: Attach the hose to the manifold
inlet fitting with a national standard NG connector and secure the hose to the manifold inlet
fitting as shown in FIG.03 below. NOTE: Installation and service must be performed by a
qualified installer, service agency or your gas provider.
FIG.01
FIG.02
FIG.03

9
ASSEMBLY INSTRUCTIONS
UINSTALLATION TO YOUR WOODEN TABLE
Get the cardboard SR2201BI/I2+ & SRRBI/I2+: 31cm x 31cm, SR4001BIS/I2+ &
SR4001BIR/I2+: 40cm x 40cm from the package and use it to draw and saw off the built-in area
on the center of your wooden table. After the gas hose connection, place the build-in gas fire
burner kit onto the opening of your wooden table as shown in FIG. 01
NOTE: You may need to use and attach the optional table support bracket kit as shown in FIG.
02 to secure the slats you saw off. Adjust and secure underneath the slats you saw off at proper
positions by screws. The optional table support bracket kit is available from the same dealer or
qualified installer. NOTE: The thickness of the table countertop should not be less than 1 cm;
the height of the table should not be less than 62 cm.
FIG.01
FIG.02
This manual suits for next models
3