Hach sension8 User manual

Cat. No. 54550-18
Dissolved Oxygen Meter
© Hach Company, 1999. All rights reserved. Printed in the U.S.A. ap/dk 9/99 1ed

2
TRADEMARKS OF HACH COMPANY
AccuGrow
AccuVac
AccuVer
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
2
2®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
®
ACS-Plus™
AgriTrak™
AluVer
AmVer™
APA 6000™
AquaCheck™
AquaTrend™
BariVer
BiVer
BODTrak™
BoroTrace™
BoroVer
C. Moore Green™
CalVer
ChromaVer
ColorQuik™
CoolTrak
CuVer
CyaniVer
Digesdahl
DithiVer
Dr. F. Fluent™
Dr. H.Tueau™
DR/Chek™
FerroMo
FerroVer
FerroZine
FilterTrak™660
Formula 2533™
Formula 2589™
Gelex
H O University™
H OU™
Hach Logo
Hach One
Hach Oval
Hach.com™
HachLink™
Hachology™
HexaVer
HgEx™
HydraVer
ICE-PIC™
IncuTrol
LeadTrak
m-ColiBlue 24
ManVer
MercuVer
MolyVer
Mug-O-Meter
NetSketcher™
NitraVer
NitriVer
NTrak
OASIS™
OptiQuant™
On Site Analysis.
ResultsYou Can Trust™
OriFlow™
OxyVer™
PathoScreen™
PbEx
PermaChem
Phillip D. Glass™
PhosVer
Pocket Colorimeter™
Pocket Pal™
Pocket Turbidimeter™
“Pond in Pillow”™
PourRite™
PrepTab™
ProNetic™
Pump Colorimeter™
QuanTab
Rapid Liquid™
RapidSilver™
Ratio™
RegeneVer™
RoVer
™
“Simply Accurate”™
SofCheck™
SoilSys™
Spec ™
StablCal
StannaVer
StillVer
SulfaVer
Surface Scatter
TanniVer
TenSette
Test ‘N Tube™
TitraStir
TitraVer
ToxTrak™
UniVer
VIScreen™
Voluette
WasteAway™
WaveCheck™
ZincoVer
Sens
ion
√

3
TABLE OF CONTENTS
SAFETY PRECAUTIONS ....................................................................................................... 7
SPECIFICATIONS.................................................................................................................... 9
OPERATION........................................................................................................................11
SECTION 1 INTRODUCTION...................................................................................... 13
1.1 Unpacking the Instrument................................................................................................. 14
1.1.1 Standard Accessories............................................................................................... 14
1.1.2 Optional Accessories............................................................................................... 14
1.2 Keypad Description........................................................................................................... 14
1.3 Display Fields and Icons ................................................................................................... 16
1.4 Maintenance ...................................................................................................................... 19
1.5 Audible Signals................................................................................................................. 19
SECTION 2 INSTRUMENT SETUP............................................................................ 21
2.1 Instrument Description...................................................................................................... 21
2.2 Power Connection ............................................................................................................. 21
2.3 Printer and Computer Connections................................................................................... 22
2.4 Turning the Meter On........................................................................................................ 22
SECTION 3 INSTRUMENT OPERATION................................................................ 23
3.1 Setup Menu ....................................................................................................................... 23
3.1.1 Turning Display Lock Off and On........................................................................... 23
3.1.2 Selecting Metric or English Units............................................................................ 23
3.1.3 Selecting Measurement Resolution ......................................................................... 24
3.1.4 Adjusting for Sample Salinity.................................................................................. 24
3.1.5 Changing the Barometric Pressure. ......................................................................... 25
3.1.6 Adjusting the Altitude.............................................................................................. 26
3.1.7 Setting the Time....................................................................................................... 27
3.1.8 Setting the Date........................................................................................................ 28
3.1.9 Setting the Year........................................................................................................ 28
3.1.10 Automatic Data Transfer ....................................................................................... 29
3.2 Calibrating the Meter ........................................................................................................ 30
3.3 DO Probe........................................................................................................................... 31
3.3.1 Probe Assembly....................................................................................................... 31
3.3.2 Probe Polarization.................................................................................................... 32
3.3.3 Zeroing the Probe .................................................................................................... 33
3.3.4 Calibration in Water Saturated Air .......................................................................... 34
3.3.5 Calibration to a Known Dissolved Oxygen Concentration ..................................... 35

4
TABLE OF CONTENTS, continued
3.3.6 Calibrating a Sample to Read 100% Saturation...................................................... 37
3.3.7 Calibration Review.................................................................................................. 38
3.4 Measuring Dissolved Oxygen........................................................................................... 39
3.4.1 General Probe Operation......................................................................................... 39
3.4.2 Measurement........................................................................................................... 39
3.4.3 Probe Storage .......................................................................................................... 40
3.4.4 Maintenance............................................................................................................ 41
3.5 Using the BOD Accessory Kit.......................................................................................... 41
3.6 Making BOD Determinations........................................................................................... 42
3.7 Oxygen Utilization Rate (OUR) and Specific Oxygen Utilization Rate (SOUR) Tests... 42
SECTION 4 STORING AND RECALLING DATA.................................................. 45
4.1 Storing Measurements ...................................................................................................... 45
4.2 Recalling Stored Data....................................................................................................... 46
4.3 Erasing Data...................................................................................................................... 47
4.3.1 Erasing Single Data Points...................................................................................... 47
4.3.2 Erasing All Data Points........................................................................................... 47
SECTION 5 MAINTENANCE....................................................................................... 49
5.1 Cleaning the Probe............................................................................................................ 49
5.2 Meter Maintenance........................................................................................................... 49
SECTION 6 PRINTING AND DATA TRANSFER................................................... 51
6.1 Connecting to Printers/Computers.................................................................................... 51
6.1.1 Connection with the RS232 Cable.......................................................................... 51
6.1.2 Connecting to a Printer............................................................................................ 51
6.1.3 Connecting to a Personal Computer........................................................................ 53
6.2 Sending Data to Printers/Computers................................................................................. 55
6.2.1 Sending Currently Displayed Data.......................................................................... 55
6.2.2 Sending Recalled Data Points................................................................................. 55
6.2.3 Sending All Stored Data.......................................................................................... 55
6.2.4 Printed Data Format................................................................................................ 56
SECTION 7 DISSOLVED OXYGEN IN WATER..................................................... 57
SECTION 8 TROUBLESHOOTING............................................................................ 63
8.1 Error Codes....................................................................................................................... 63
8.2 Meter Service Request Questionnaire............................................................................... 63

5
TABLE OF CONTENTS, continued
SECTION 9 REFERENCE TABLES............................................................................ 65
9.1 Salinity Correction Factors................................................................................................ 65
9.2 Barometric Pressure and Elevation ................................................................................... 66
9.3 Solubility of Oxygen in Water .......................................................................................... 67
9.4 Pressure Conversions......................................................................................................... 73
GENERAL INFORMATION...........................................................................................75
REPLACEMENT PARTS....................................................................................................... 77
HOW TO ORDER................................................................................................................... 78
REPAIR SERVICE.................................................................................................................. 79
WARRANTY .......................................................................................................................... 80
CERTIFICATION ...................................................................................................................81

6

8

9
SPECIFICATIONS
Specifications subject to change without notice.
Oxygen Measurement:
Range 0-20 mg/L (ppm)
0-200% sat.
Accuracy ± 1% full scale
Temperature 0-50 °C
Resolution:
Oxygen Concentration 0.01 or 0.1 ppm (mg/L)
%Saturation 0.1%
Temperature 0.1 °C
Display: Custom LCD
Inputs: Outputs:
5-pin shielded RS232C
circular connector
Power Requirements: 6–12 Vdc; use either Hach-supplied 115 or 230V, 50/60 Hz external
power supply or a customer-provided supply with 50 mA output, 5.5-mm power plug with a
2.5 mm center post opening
Installation Category: II
Instrument drift: <1%/day
Environmental requirements: 5 to 50 °C at 85% relative humidity, non-condensing
Meter dimensions: 15x25.4x8.37cm(10.15x6x3.5inches)
Enclosure: Water resistant (IP32), chemical resistant
Probe Dimensions (Model 50180):
Probe Length 150 mm
Body Diameter 12 mm
Cap 15 mm dia. x 35 mm
Cable Length 1, 3, or 15 meters
Connector Fisher

10
Table of contents
Other Hach Analytical Instrument manuals

Hach
Hach 9586sc Quick manual

Hach
Hach Polymetron 9582sc User manual

Hach
Hach NV3300 User manual

Hach
Hach CL17sc User manual

Hach
Hach PHC28101 User manual

Hach
Hach PHOSPHAX indoor sc User manual

Hach
Hach ORBISPHERE 32301 Quick manual

Hach
Hach Lange ORBISPHERE 3100 Quick manual

Hach
Hach Polymetron 9526 Quick manual

Hach
Hach Polymetron 9610sc SiO2 User manual