Growonix BP-1530 User manual

1
www.growonix.com toll free 888.406.8521, oce 818.510.0264, sales@growonix.com
BP-1530
Booster Pump
Owners Manual
www.growonix.com

2
WHY USE A
GROWONIX BP1530 ?
Membranes love pressure! In general, more
pressure allows for better emembrane rejection,
longer membrane life, and increased membrane
ow rate. GrowoniX BP-6010 Series Booster
Pumps allow for the full potential performance
of the RO membrane to be acheived—with
only 35 PSI of incoming water pressure. The
perfect solution for those with low feed water
pressures, and those who want to receive the
maximum performance from their GrowoniX
water lter.
BP-1530 SYSTEMS FEATURES
Continuous duty cycle
Adjustable output pressure
Controllable manually or with ESOK
(electric shuto kit)
Patented electrogalvanized bracket on
BP-6010-CH

3
www.growonix.com toll free 888.406.8521, oce 818.510.0264, [email protected]
OUR MISSION
Durability, Reliability, Eciency, Purity, and Conservation form the foundation on which we design
and build all of our products. Consistent and superior quality sets us apart from other manufacturers
and increases our value to you - our customer. Whether you are a hydroponics hobbyist, serious
enthusiast, or large-scale gardener, GrowoniX is committed to bringing you the best solution for
water purication systems.
WHAT IS REVERSE OSMOSIS?
Reverse osmosis (RO) is a ltration method that removes many types of large molecules and ions
from solutions by applying pressure to the solution when it is on one side of a selective membrane.
This ltering process ensures that the solute (waste water) is contained within the pressurized
chamber while the pure solvent (RO water) is allowed to pass freely through the membrane.
TUNED FOR GROWING - IN TUNE WITH OUR CUSTOMERS
Traditional RO systems have waste ratios of approximately 4:1, which means there are 4 gallons
of waste water produced for every 1 gallon of puried water. GrowoniX line of water lters achieve
waste ratios of 2:1 with the EX100 through GX400 and an astounding 1:1 ratio with the GX600 and
GX1000.
GrowoniX has created a complete product line that will address the needs of hydroponic operations
of all sizes. Our lters will signicantly reduce your water use while dramatically increasing your yields.
INTRODUCTION
THE TRADITIONAL WAY
takes 4 gallons of waste water to produce 1 gallon of pure water
WASTE WATER PURE WATER
THE GrowoniX WAY
WASTE WATER PURE WATER

4
INFORMATION ON QUICK CONNECT FITTINGS
INSERT TUBE INTO FITTING
Push the tubing through the collet and dual o-rings until it bottoms out against the tube stop.
The collet holds the tube in place and the dual o-rings provide a leak resistant seal.
MAKE A CLEAN TUBE CUT
Cut the tube squarely and if using plastic tubing, ensure that the cut has not made the tube out of round.
Also ensure that the tube has a smooth outside diameter without any burrs or score marks
prior to inserting it into the tting.
TEST AND INSPECT
Push and pull the tubing toward and away from the tting to ensure that it has been installed properly.
Test and inspect the installation for any leaks.
TUBE REMOVAL
Relieve pressure from the tubing and tting. Push uniformly around the collet ange against the
tting body while pulling the tubing away from the tting to release it.
O-RING
COLLET
TUBING
PUSH COLLET IN
PULL TUBE OUT
GROWONIX WATER FILTERS USE QUICK CONNECT FITTINGS
THAT ALLOW FOR EASY MAINTENANCE.

5
www.growonix.com toll free 888.406.8521, oce 818.510.0264, [email protected]
• The GX150/300 Booster Pump is designed for use with all GrowoniX water lters 600 GPD and under.
• The pump is designed to boost low water pressure conditions to optimal pressure.
We recommend not exceeding 79 psi output pressure.
ABOUT
CAUTIONS
MOUNTING
PLUMBING
PLEASE READ THESE OPERATIONAL AND INSTALLATION GUIDELINES
BEFORE INSTALLING THE “CDP” BOOSTER PUMP.
IF ADDITIONAL HELP IS NEEDED, PLEASE CONSULT THE FACTORY.
• The pump is equipped with an adjustable bypass valve which controls the maximum operating
pressure. In addition, never subject the pump to pressures above 79 PSI.
• Never operate the pump in a harsh environment or hazardous atmosphere,
since motor brush and switch may cause electrical arcing.
• Pumphead materials are designed for use with water only. Do not use with petroleum products.
• Always consider electrical shock hazard when working with and handling electrical equipment.
If uncertain, consult an Electrician. Electrical wiring should only be done by a qualied Electrician
per Local and State Electrical Codes.
• The pump should be mounted in a dry place and away from any source of heat. If an enclosure is
used, special provisions for cooling the motor may be necessary. Consult the Factory.
• Do not subject the pump to extreme high or low (freezing) temperatures while in operation.
(Operating ambient temperature range is 32ºF to 115ºF).
• The pump may be mounted in any position. If “ceiling mounted”, however, with the pumphead
upside down, air entrapment may reduce the operational performance by up to 15% .
Consult Aquatec for ceiling mount solutions.
• We recommend use of exible tubing with proper pressure rating.
• Pump will prime only if all pressure is relieved from the outlet port.
• It is recommended that an in-line sediment lter (150 micron or 100 mesh) be installed at the inlet
side to keep foreign debris out of the system.
Please consult your GrowoniX catalog for an in-line lter.
• Avoid any sharp bends which may crimp tubing and restrict ow. Use 90º elbow ttings if necessary.
• The pump should always be mounted prior to the carbon pre-lter to prevent carbon particles
from entering the pump chambers and possibly causing clogging.
OPERATIONAL AND INSTALLATION GUIDELINES
GROWONX BP-1530 SERIES BOOSTER PUMP

6
FLOW RATES
600GPD—1000GPD FILTER FLOW RATES
WATER PRESSURE (PSI) WITH OR WITHOUT PUMP
2400
2600
2800
EX/GX1000-HF, 77ºF
EX/GX1000-HF, 60ºF
EX/GX1000-HF, 50ºF
EX/GX600-HF, 77ºF
EX/GX600-HF, 60ºF
EX/GX600-HF, 50ºF
2200
2000
1800
1600
1400
1200
1000
800
600
400
200
0
GALLONS PER DAY
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
100GPD—400GPD FILTER FLOW RATES
WATER PRESSURE (PSI) WITH OR WITHOUT PUMP
600
550
500
450
400
350
300
250
200
150
100
50
0
EX/GX200-HF, 50ºF
EX/GX200-HF, 60ºF
EX/GX200-HF, 77ºF
EX/GX400-HF, 60ºF
EX/GX400-HF, 77ºF
EX/GX400-HF, 50ºF
EX100-HF, 50ºF
EX100-HF, 60ºF
EX100-HF, 77ºF
40 45 50 55 65 7560 70 80
GALLONS PER DAY

7
www.growonix.com toll free 888.406.8521, oce 818.510.0264, [email protected]
REPLACEMENT PARTS
PRODUCT TYPE APPLICATION / SYSTEM MSRP CAPACITY NOTES
REPLACEMENTS FOR ALL WATER FILTERS 400 GPD AND UNDER
SF-2510-PL Sediment Pleated EX100/200/400/400-Tall, GX200/300/400, Mini Scrub 14.50 Depends on feed water piping/supply Stock on GX Series
SF-2510-SP Sediment Spun EX100/200/400/400-Tall, GX200/300/400, Mini Scrub 10.75 Depends on feed water piping/supply Stock on EX Series
CF-2510-CC Economy Coco Carbon EX100/200/400/400-Tall, GX200/300/400, Mini Scrub 12.00 7,500 Gallons Total
2,500 Gallons RO Water Stock on EX Series
CF-2510-GB Green Carbon EX100/200/400/400-Tall, GX200/300/400, Mini Scrub 16.50 7,500 Gallons Total
2,500 Gallons RO Water, Stock on GX Series
CF-2510-KDF Premium Carbon EX100/200/400/400-Tall, GX200/300/400, Mini Scrub 39.00 8,000 Gallons Total 2,700 Gallons RO Water Must for well water and chloramine removal
GXM-100 Standard Membrane 100+ GPD membrane for EX100 83.00 Depends on feed water quality Fits most other RO systems
GXM-200-HF High Flow Cold Water
Membrane
200+ GPD High Flow Cold Water Membrane for EX100/200/400/400-Tall,
GX200/300/400 99.00 Depends on feed water quality Fits most other RO systems
BP-1530 Booster Pump Booster pump for all RO systems 600 GPD and under. 227.00 12,000 Hrs brush life Booster pump for all RO systems 600 GPD and under
REPLACEMENTS FOR EX400HF-TALL AND SLIMSCRUB
SF-2520-SP Sediment Spun EX400-tall, Slim Scrub 10.75 Depends on feed water piping/supply
CF-2520-CC Economy Coco Carbon EX400-tall, Slim Scrub 24.00 16,000 Gallons Total
5,300 Gallons RO Water
CF-2520-KDF Premium Carbon EX400-tall, Slim Scrub 71.00 17,000 Gallons Total
5,700 Gallons RO Water Must for well water and chloramine removal
CF-4520-KDF Premium Carbon EX600/1000-Tall, XL Scrub 127.00 34,000 Gallons Total
17,000 Gallons RO Must for well water and chloramine removal
PRODUCT TYPE MSRP SYSTEM NOTES
SPECIALTY FILTRATION, ACCESORIES & REPLACEMENTS
ALK-Inline Alkaline 99.00 All RO systems Raises ph, adds cal/mag mineral.
ALK-Cart Alkaline 99.00 All RO systems Raises ph, adds cal/mag mineral.
RM-Inline Re-Mineralize 67.00 All RO systems Adds cal/mag minerals.
RM-CART Re-Mineralize 67.00 All RO systems Adds cal/mag minerals.
DI-Inline De-Ionization 31.00 All RO systems Removes remaining TDS after RO (aquarium, lab)
DI-Cart De-Ionization 34.00 All RO systems Removes remaining TDS after RO (aquarium, lab)
UV-1530 Ultraviolet 149.00
All RO, Scrubber
systems, tank
storage
Kills 99.9% bacteria
UV-6010 Ultraviolet 215.00
All RO, Scrubber
systems, tank
storage
Kills 99.9% bacteria / viruses
UV-LB Ultraviolet 443.00
All RO, Scrubber
systems, tank
storage
Kills 99.9% bacteria / viruses
UV-XL Ultraviolet 538.00
All RO, Scrubber
systems, tank
storage
Kills 99.9% bacteria / viruses
COCONUT CARBON FILTER— “GREEN BLOCK”
PREMIUM COCO CARBON, PRODUCED USING ECO-FRIENDLY LOW
EMISSIONS PROCESSES
COCONUT CARBON FILTER—”WHITE BLOCK”
ECONOMY COCO CARBON, SAME PERFORMANCE AS GREEN
BLOCK, FOR A LITTLE LESS MONEY.
KDF85/CATALYTYIC ACTIVATED CARBON FILTER
PREMIUM CARBON FILTER USING THE BEST ACTIVATED CARBON WITH
A BED OF KDF85 MEDIA. THERE’S NO BETTER CARBON AVAILABLE.
SEDIMENT SPUN
SPUN POLY SEDIMENT FILTERS WITH HUGE DIRT HOLDING CAPACITY.
SEDIMENT PLEATED
HIGH FLOW SEDIMENT FILTERS WITH ULTRA LOW PRESSURE DROP.
GXM INDUSTRIAL MEMBRANES
HIGHEST FLOWING DOW SHEET MEMBRANES ON THE PLANET, WITH
THE LOWEST WASTE RATIO.
GXM HIGH FLOW COLD WATER MEMBRANES
HIGHEST FLOWING RESIDENTIAL SIZED MEMBRANES.
ALWAYS 2:1 RATIO.
ALKALINE INLINE
INLINE FILTER ADDS CALCIUM & MAGNESIUM TO FILTERED WATER,
RAISES THE PH.
ALKALINE CARTRIDGE
CARTRIDGE ADDS CALCIUM & MAGNESIUM TO FILTERED WATER,
RAISES THE PH.
REMINERALIZING INLINE
INLINE FILTER ADDS CALCIUM & MAGNESIUM TO FILTERED WATER,
REMINERALIZING CARTRIDGE
CARTRIDGE ADDS CALCIUM & MAGNESIUM TO FILTERED WATER,
UV STERILIZATION
KILLS 99.9% BACTERIA AND VIRUSES.
DI INLINE
DE-IONIZATION FILTER REMOVES LAST BIT OF PPM.
MEMBRANE INDEX

8
1
3 2
6
4
5
BP-1530 BOOSTER PUMP COMPONENT DIAGRAM
1. MOTOR
2. PUMP INLET
3. PUMP OUTLET
4. PRESSURE SWITCH
5. ADJUSTABLE INTERNAL BYPASS
6. POWER TRANSFORMER
READ ENTIRE MANUAL THOROUGHLY
BEFORE INSTALLING THIS PRESSURE-BOOSTING PUMP

9
www.growonix.com toll free 888.406.8521, oce 818.510.0264, [email protected]
BP1530 ASSEMBLY DIAGRAM

10
2
4
1
3
SETUP INSTRUCTIONS
input
input output
output
Make note of direction of ow prior to
installation.
Connect feed water tubing to pump
input.
Insert output tubing into pump output.
Insert output tubing into RO lter input.
Other manuals for BP-1530
1
Table of contents
Other Growonix Water Pump manuals
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual