gefran Vedo EL35CT User manual

1
80951C_MHW_GF_VEDO EL35CT-EL57CT_03-2010_ENG
GF_VEDO EL35CT-EL57CT
Code 80951C / Edition 04 -03-2010
INSTALLATION AND
OPERATION MANUAL
GENERAL INDEX
page
Graphic symbols used 2
1 Preliminary instructions 3
General description 3
Preliminary warnings 3
2 Installation and Connection 4
Electrical power supply 4
Notes concerning electrical safety and
Electromagnetic compatibility 4
Instrument power supply 5
Inputs and outputs connection 5
Dimensions 6
Fixing 8
3 Technical Specifications 10
3.1 Display 10
3.2 CPU and Memory 10
3.3 Supported Operating Systems 10
3.4 Keyboard 10
3.5 User connections 11
3.5.1 Power supply port 12
3.5.2 RS-485 port 13
3.5.3 Ethernet port 13
3.5.4 USB port 14
3.5.5 CAN - CANopen port 14
3.5.6 CAN - DeviceNet port 14
3.5.7 Battery 15
3.5.8 Configuration 15
3.6 Expansion 16
page
4 Connection Examples 20
5 Summary of Characteristics 21
6 Technical-Commercial information 22
Order code 22

280951C_MHW_GF_VEDO EL35CT-EL57CT_03-2010_ENG
Gefran S.p.A. All Rights Reserved
This manual is the sole property of GEFRAN S.p.A.
The information in this manual is reserved and confiden-
tial. No part of this manual may be reproduced, photo-
copied, transmitted, transcribed, or translated into other
languages, with computers or in any other way (electro-
nic, mechanical, magnetic, optical, chemical, manual,
etc.) without explicit written permission from Gefran
S.p.A.
IMPORTANT
Although all of the information in this manual has been
carefully checked, Gefran S.p.A. assumes no liability
with regard to possible errors, or with regard to damage
to persons or property due to improper use of this
manual.
The same applies with regard to persons or companies
involved in the writing or production of this manual.
Gefran S.p.A. reserves the right to change the contents
and structure of this manual and to change product spe-
cifications at any time and without notice.
Gefran S.p.A. does not issue any type of guarantee with
regard to this manual, including but not limited to implicit
guarantees of marketability and suitability for a defined
purpose.
Gefran S.p.A. declines all liability with regard to the use
of its software on devices not supplied by Gefran S.p.A.
Windows™ is a registered trademark of Microsoft
Corporation.
PREFACE
This manual provides a detailed description of the main
technical data of the various versions of Gefran’s pro-
duct.
The following information is indispensable for the cor-
rect use of the product: proper wiring, correct jumper
settings and the correct connection to external devices.
Keep in mind that most of the hardware options can be
configured via software by means of the setup data sto-
red in the eeprom. As a result, there are just a few
options solely for hardware, which significantly simplifies
configuration of the product.
Graphic symbols
Graphic symbols are used to differentiate among the types and importance of the information in these Instructions
and to facilitate the reader’s understanding.
Indicates the contents of the various sections of
the manual, general warnings, notes, and other
important points.
Indicates a particularly delicate situation that could
affect the safety or good operation of the product,
or an instruction that must absolutely be followed
in order to prevent hazardous situations.
Indicates a risk to the user’s safety due to the pre-
sence of high voltage at the specified points.
Indicates a suggestion (based on the experience
of GEFRAN Technical Personnel) that could be
very useful under certain circumstances.
Information of a general and applicative
nature.
Important notes for product safety and
reliability.
Indicates a reference to Detailed Technical
Documents available on GEFRAN’s web-
site: www.gefran.com

3
80951C_MHW_GF_VEDO EL35CT-EL57CT_03-2010_ENG
Preliminary warnings
Read the following preliminary warnings before
installing and using the operator terminals.
Doing so makes start-up quicker and lets you
avoid some problems that might be mistaken
for malfunctions or limitations of the terminal.
• Immediately after unpacking the product, make a note
of the order code and the other identification data given
on the label affixed to the outside of the container and
copy them to the table below.
These details must always be kept close at hand and
referred to the personnel involved in the event of help
from Gefran Customer Service Assistance.
• Check that the terminal is in perfect condition and was
not damaged during shipment. Make sure that the pac-
kage also contains the fastening accessories.
Any inconsistencies, omissions or evident signs of
damage should be reported immediately to your Gefran
sales agent.
• Check that the order code corresponds with the confi-
guration requested for the application the terminal is
needed for, referring to Section: “Technical - Commercial
Information”.
Example: GF_VEDO - 35CT - LX0 - S1 - C1 - U - G
• Model: 35CT
• Operating System: Linux
• Peripherals: RS485 serial
CANopen
USB
• Lexan: standard Gefran
Consult the section “Installation and Connection” before
installing the terminal on the machine control panel or
host system Consult the section “Sales Information” for
the order code. Users and/or system integrators who
want more detailed information on serial communication
between standard PCs and/or Gefran Industrial PCs
and Gefran Programmable Instruments may access the
various Technical Reference Documents in PDF format
available on Gefran’s website: www.gefran.com.
In the event of presumed instrument malfunction, before
contacting Gefran Technical Service Assistance, refer to
the Troubleshooting Guide given in Section "Maintenan-
ce", and if necessary refer to the F.A.Q. Section (Fre-
quently Asked Questions) on the Gefran Web Site
www.gefran.com
SN: ......................... (Serial no.)
CODE: ......................... (Finished product code)
TYPE: ......................... (Order Code)
SUPPLY: ......................... (Type of electrical power supply)
VERS: ......................... (Software version)
1 • PRELIMINARY INSTRUCTIONS
This section contains information and warnings of a general nature which should be read before procee-
ding with terminal installation, configuration and use.
General description
The operator terminals are a compact and low-cost
solution for machine control.
A single product integrates machine cycle control
[SoftPLC] and graphic page display [SCADA], allowing
quick and low-cost creation of many automation solu-
tions.
The operator terminals creates the machine/operator
interface by means of LCD monitor, touch-screen, and a
wide variety of peripheral I/Os.
The operator terminals are applied mainly to machine
control for packaging, metals, wood and plastic applica-
tions. This Installation Guide describes the main charac-
teristics of the operator panels and refers to the follo-
wing models:
GF_VEDO EL35CT operator interface with 3.5” color touch-screen LCD TFT Ethernet port,
integrated I/Os [optional], Fieldbus port [optional], USB port [optional]
GF_VEDO EL57CT operator interface with 5.7” color touch-screen LCD TFT Ethernet port,
integrated I/Os [optional], Fieldbus port [optional], USB port [optional]

480951C_MHW_GF_VEDO EL35CT-EL57CT_03-2010_ENG
2 • INSTALLAZIONE e COLLEGAMENTO
This section contains the instructions necessary
for correct installation of the terminals into the
machine control panel or the host system and
for correct connection of the controller power
supply, inputs, outputs and interfaces.
Before proceeding with installation read the
following warnings carefully!
Remember that lack of observation of these
warnings could lead to problems of electrical
safety and electromagnetic compatibility, as
well as invalidating the warranty.
Electrical power supply
• the terminal is NOT equipped with an On/Off
switch: the user must provide a two-phase
disconnecting switch that conforms to the required
safety standards (CE marking), to cut off the power
supply upstream of the terminal.
The switch must be located in the immediate vicinity of
the terminal and must be within easy reach of the
operator.
One switch may control more than one terminal
• if the terminal is connected to NOT isolated electrical
equipment (e.g. thermocouples), the earth connection
must be made with a specific conductor to prevent the
connection itself from coming directly through the
machine structure.
• if the terminal is used in applications with risk
of damage to persons, machinery or materials, it is
essential to connect it up to auxiliary alarm
equipment. It is advisable to make sure that alarm
signals are also triggered during normal operation.
The terminal must NOT be installed in flammable or
explosive environments; it may be connected to
equipment operating in such atmospheres only by
means of appropriate and adequate types of
interface, conforming to the applicable safety
standards.
Notes Concerning Electrical Safety and
Electromagnetic Compatibility:
CE MARKING: EMC Conformity (electromagnetic
compatibility)
in accordance with Directive 2004/108/CE.
The terminals are mainly designed to operate in indu-
strial environments, installed on the switch boards or
control panels of productive process machines or
plants. As regards electromagnetic compatibility, the
strictest generic standards have been adopted, as indi-
cated in the table below.
BT Conformity (low voltage) in accordance with
Directive 2006/95/CE.
EMC conformity has been tested with the following
connections.
Generic standards emission standard
for industrial environment
Emission enclosure EN 61000-6-4
CISPR-11 Generic norm
Class A
EMC EMISSION
EMC IMMUNITY
Programmable Controllers
ESD immunity
RF interference immunity
Radiofrequency interference
Burst immunity
Pulse immunity
Magnetic fields immunity
Voltage dips, short interruptions and voltage immunity tests
EN 61131-2
EN 61000-4-2
EN 61000-4-3
EN 61000-4-6
EN 61000-4-4
EN 61000-4-5
EN 61000-4-8
EN 61000-4-11
Product Standard
± 4 kV contact discharge
± 8 kV air discharge
10 V/m amplitude modulated
80 MHz-1 GHz
10 V/m amplitude modulated
1.4 GHz-2 GHz
3 V/m amplitude modulated
0.15 MHz-80 MHz
± 2 kV power line
± 1 kV signal line
0,5 kV common mode
100 A/m
100%U, 10ms
Low voltage directive safety EN 61010-1
LOW VOLTAGE DIRECTIVE SAFETY
Table 1 - EMC Emission
Table 2 - EMC Immunity
Table 3 - LVD Safety

5
80951C_MHW_GF_VEDO EL35CT-EL57CT_03-2010_ENG
Instrument power supply
Installation categoryII and pollution degree 2.
• The power supply to the electronic equipment on the
switchboards must always come directly from an
isolation device with a fuse for the instrument part.
• The electronic instruments and electromechanical
power devices such as relays, contactors, solenoid
valves, etc., must always be powered by separate
lines.
• When the electronic instrument power supply is
strongly disturbed by voltage problems from power
units or motors, an isolation transformer should be
used for the controllers only, earthing the screen.
• It is essential that the plant has a good earth
connection:
- the voltage between neutral and earth must not be >1V
- the resistance must be < 6Ω;
• If the mains voltage fluctuates strongly, use a voltage
stabilizer.
• In the proximity of high frequency generators or arc
welders, use adequate mains filters.
• The power supply lines must be separate from the
instrument input and output ones.
Inputs and outputs connection
• To connect the analogue inputs, strain gauge,
linear, (TC, RTD) the following is necessary:
- physically separate the input cables from those of the
power supply, the outputs and the power connections.
- use woven and screened cables, with the screen
earthed in one point only.
• To connect the control outputs, alarm(contactors,
solenoid valves, motors, fans, etc.), fit RC groups
(resistance and condensers in series) in parallel to
the inductive loads that operate in Alternating
Current.
(Note: all the condensers must conform to VDE
(class X2) standards and withstand a voltage of at
least 220V AC. The resistances must be at least 2W).
• Fit a 1N4007 diode in parallel with the coil of the
inductive loads that operate in Direct Current.
GEFRAN S.p.A. declines all responsibility for any
damage to persons or property caused by tampe-
ring, neglect, improper use or any use which
does not conform to the characteristics of
the controller and to the indications given in
these Instructions for Use.
Prescription UL
- Operating surrounding air temperature rating of 50°C
- For use on a flat surface of a type 1 enclosure

680951C_MHW_GF_VEDO EL35CT-EL57CT_03-2010_ENG
Dimensions
All measurements are expressed in mm, with tolerance of ± 0.5.
GF_VEDO EL35CT dimensions
Fig. 1 - Dimensions and cut-out GF_VEDO EL35CT
3 max
12,9 66,9 90,5
93
93
92 4
61 12,5
100
8,3100
Fig. 2 - Dimensions GF_VEDO EL35CT
GILOGIK II modules
(optional)

7
80951C_MHW_GF_VEDO EL35CT-EL57CT_03-2010_ENG
Fig. 3 - Dimensions and cut-out GF_VEDO EL57CT
179
88,5
65
3 max
7,5
162
115
120
169
Fig. 4 - Dimensions GF_VEDO EL57CT
GILOGIK II modules
BUS-G
GF_VEDO 57CT
GF_VEDO EL57CT dimensions

880951C_MHW_GF_VEDO EL35CT-EL57CT_03-2010_ENG
Fixing
Panel mounting
GF_VEDO EL35CT and GF_VEDO EL57CT panels are designed for front panel installation.
After making the opening shown on the template drawing, fasten the terminal with the blocks required and supplied
with the product.
Fig. 5 - Panel mounting GF_VEDO EL35CT
Fig. 6 - Panel mounting GF_VEDO EL57CT

9
80951C_MHW_GF_VEDO EL35CT-EL57CT_03-2010_ENG
To maintain IP65 protection level during panel installation, pay attention to the following points:
• make the edges of the hole for the panel perfectly smooth and flat
• tighten each fastening screw
The terminals also have an O-Ring inserted at the rear of the display frames.
Cleaning the device
Clean the device only with a soft cloth and non-abrasive neutral soap. Do not use solvents.
Fig. 7 - O-Ring on GF_VEDO EL57CT terminals

10 80951C_MHW_GF_VEDO EL35CT-EL57CT_03-2010_ENG
Fig. 8 - Integrated keyboard on GF_VEDO EL35CT terminals
3 • TECHNICAL SPECIFICATIONS
3.4 Keyboard
The GF_VEDO EL35CT terminal has a 6-key keyboard integrated in the lexan front panel.
3.1 Display
35CT: 3.5” color LCD TFT (Thick Film Transistor) display
57CT: 5.7” color LCD TFT (Thick Film Transistor) display
3.2 CPUs and Memories
The terminals are equipped with EP9307 processors with ARM9 core.
Memories: 64MB FLASH mass, 64MB DRAM system, 256KB cache.
3.3 Supported Operating Systems
The terminal is supplied with the operating system Linux
This manual suits for next models
1
Table of contents
Other gefran Touch Terminal manuals