Gecko Aeware 3 in.ye User manual

in.ye
spa pack general operation
(pages 2-7)
•
in.k450
keypad operation
(pages 9-15)
•
in.clear
water sanitation system operation
(pages 16-43)
•
in.stream
sound system operation
(pages 44-47)

32
in.xe™in.xe™
WARNINGS:
Before installing or connecting the unit, please read the following.
* FOR UNITS FOR USE IN OTHER THAN SINGLE-FAMILY DWELLINGS, A CLEARLY LABELED
EMERGENCY SWITCH SHALL BE PROVIDED AS PART OF THE INSTALLATION. THE SWITCH
SHALL BE READILY ACCESSIBLE TO THE OCCUPANTS AND SHALL BE INSTALLED AT LEAST
5 FEET (1.52 M) AWAY, ADJACENT TO, AND WITHIN SIGHT OF THE UNIT.
* ANY DAMAGED CABLE MUST BE IMMEDIATELY REPLACED.
* TURN POWER OFF BEFORE SERVICING OR MODIFYING ANY CABLE CONNECTIONS IN
THIS UNIT.
* TO PREVENT ELECTRIC SHOCK HAZARD AND/OR WATER DAMAGE TO THIS CONTROL,
ALL UNUSED RECEPTACLES MUST HAVE A DUMMY PLUG.
* THIS CONTROLLER MUST NOT BE INSTALLED IN PROXIMITY OF HIGHLY FLAMMABLE
MATERIALS.
* LOW VOLTAGE OR IMPROPER WIRING MAY CAUSE DAMAGE TO THIS CONTROL
SYSTEM. READ AND FOLLOW ALL WIRING INSTRUCTIONS WHEN CONNECTING TO
POWER SUPPLY.
* THIS PACK CONTAINS NO SERVICEABLE PARTS. CONTACT AN AUTHORIZED SERVICE
CENTER FOR SERVICE.
* ALL CONNECTIONS MUST BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE
WITH THE NATIONAL ELECTRICAL CODE AND ANY STATE, PROVINCE OR LOCAL
ELECTRICAL CODE IN EFFECT AT THE TIME OF THE INSTALLATION.
warnings overview
in.ye
user instructions and functions

54
in.xe™in.xe™
electrical wiring
For 240 VAC (4 wires)
Correct wiring of the electrical
service box, GFCI, and pack
terminal block is essential.
ALL CONNECTIONS
MUST BE MADE BY A
QUALIFIED ELECTRICIAN
IN ACCORDANCE WITH
THE NATIONAL ELECTRICAL
CODE AND ANY STATE,
PROVINCE OR LOCAL
ELECTRICAL CODE IN
EFFECT AT THE TIME OF THE
INSTALLATION.
Electrical wiring North American model
Lamp test
All the segments and LEDs are
lighting up
Software revision
Revision of the software
Low level selection
Low level selected from low
level menu. Press Light key or
wait a couple of seconds to
confirm selection. Choose Low
Level 1 (default is set at Low
Level 1).
Software number
Software part number
power-up
Boot up displayed sequence (Each parameter is displayed for 2 seconds)

76
in.xe™in.xe™spa pack error codes summary
Prr
The Prr error message indicates a problem with regulation probe.
The system is constantly verifying if temperature probe reading is
within normal limits.
Error codes Hr
An internal hardware error has been detected.
HL
Water temperature at the heater has reached 119°F.
Do not enter spa water!
Error codes indicate a failure
condition or a problem which
needs to be corrected to
ensure proper functioning of
the system. Both the error code
and the water temperature are
alternatively displayed.
All errors codes will be displayed
on the keypad display.
FLO
The system did not detect any water flow while the main pump
was running.
Specications subjet to change without prior notice.
UPL
No low level configuration software has been downloaded
into the system.
OH
Water temperature in the spa has reached 108°F.
Do not enter spa water!
Error codes
AOH
Temperature inside the spa skirt is too high, causing the internal
temperature in the in.ye™ to increase above normal limits.
spa pack error codes summary

9
in.k450 overview
in.k450
user instructions and functions

1110
in.k450 in.k450
Set Point icon
The "Set Point" icon
automatically turns on
when set point setting
menu is activated.
(SP message on display).
Filter Cycle icon
The "Filter Cycle" icon lights
up when filter cycle is on.
Pumps icon
The "Pump" indicator
numbers light up and their
icons become fast animated
when pump or blower are in
high speed, slower animated
icon when pump or blower
are in low speed.
Heater icon
The "Heater" icon lights
up when the heater is on.
It flashes when:
1- there is a call for heat
and heater has not
started yet,
2- heater has just turned
off and element is
cooling down or
3 - not enough current
available to start heater
Light icon
The "Light" icon lights
up when the light is on.
The icon's number of
rays is proportional to
the light's intensity.
Smart Winter Mode icon
The "SWM" icon automa-
tically turns on when freeze
protection is active. It flashes
while system purges the spa
plumbing.
Time, temperature
& message digits
Service icon
A problem has
been detected. Do
not enter the water!
Spa service is
required.
Progress bar
A visual indication of
the time remaining
before an equipment
is turned off or
before the end of the
standby mode.
AM/PM (˚F/ ˚C)
functions and user instructionsfunctions and user instructions
Display
"Up/Down" keys"Light" key "Pump 3 /
Blower" key
"Pump 2" key"Pump 1" key"On/Off" key
function description

1312
in.k450 in.k450
Pump 2 key
Press Pump 2 key to turn Pump
2 on. Press a second time to
turn pump off.
A built-in timer automatically
turns pump off after a 20
minute period, unless pump
has been manually deactivated
first.
Light key
Press Light key to turn light on
Subsequent presses turn lights
on and off while changing
colors.
A built-in timer automatically
turns light off after a period
of 2 hours unless it has been
manually deactivated first.
Up/Down keys
Use Up or Down key to set
desired water temperature.
The temperature setting will
be displayed for 5 seconds to
confirm your new selection.
The "Set Point" icon indicates
that the display shows the
desired temperature, NOT the
current water temperature!
Pump 3 Key (Blower)
First press:
Pump 3 ON, Blower OFF
Second press:
Pump 3 ON, Blower ON
Third press:
Pump 3 OFF, Blower ON
Fourth press:
Pump 3 OFF, Blower OFF
A built-in timer automatically
turns blower off after a 20
minute period, unless blower
has been manually deactivated
first.
functions and user instructionsfunctions and user instructions
On/Off key
Depending on the spa manu-
facturer, this key may have
different functions: On/Off,
Standby mode or quick enable
of the Economy mode.
On/Off Mode
By default, the system is always
on. Press and hold On/Off key
for 5 sec. (or Press and hold
Pump 1 key for 5 sec.) to shut the
system down for 30 minutes.
The display will toggle between
the “OFF” message and water
temperature. Press On/Off key
to restart the system before the
expiration of the 30 minutes delay.
Pump 1 key
Press Pump 1 key to turn Pump
1 on at low speed. Press a
second time to turn pump to
high speed (with a dual-speed
pump). A third time turns
pump off.
A built-in timer automatically
turns pumps and blower off
after a period of 20 minutes,
unless pump has been
manually deactivated first.

1514
in.k450 in.k450
Filter cycle frequency
Press Prog. key a fourth time.
The display will show FFxx, with
"xx" representing the number of
filter cycles per day (up to 4).
Use Up or Down key to
change setting.
Setting temperature unit
Water temperature can be
displayed in either Fahrenheit
(˚F) or Celsius (˚C). Press Prog.
key a fifth time. The display will
show either ˚F or ˚C.
Use Up or Down key to
change setting.
Press Prog. key once more to go
back to normal mode.
Note: "F" will be displayed in
in.ye Spa Packs.
Smart Winter Mode
Our Smart Winter Mode
protects your system from
the cold by turning pumps on
several times a day to prevent
water from freezing in pipes.
When temperatures around
pack drop to near freezing, the
system will enter Smart Winter
Mode. The pack will cycle
through all pumps on high for
1 minute to prevent water from
freezing in the lines.
Water temperature regulation
In a regulation cycle, the system
first generates water flow
through the heater housing
and the plumbing, in order
to ensure accurate water
temperature readings as well as
avoiding heater activation in dry
conditions.
After verifying pump activation
and taking a water temperature
reading if required, the system
automatically turns the heater
on to reach and maintain water
temperature at Set Point.
Cooldown
After heating the spa water to
the desired Set Point, the
heater is turned off, but its
associated pump (Pump 1
Low-speed or CP) remains on
for a predetermined period of
time to ensure adequate
cooling of the heating element,
this prolongs its useful life.
The heater icon flashes during
this time.
functions and user instructionsfunctions and user instructions
Setting the time
Enter Programming mode by
holding Prog. key pressed down
for 3 sec. The display will show
the current time setting.
Setting the hour: Use Up or
Down arrows to change hour
setting (AM/PM).
Setting the minutes: Press Prog.
key a second time.
Use Up or Down key to change
hour setting.
Setting filter cycle start time
To program the filter cycle, you
must enter these parameters:
the start time and frequency.
During a filter cycle, pumps run
for one minute to purge the
plumbing, then Pump 1 runs
for the programmed number
of hours.
Press Prog. key a third time.
The display will show FSxx, with
"xx" representing the starting
hour.
Use Up or Down key to
change setting.
Program key
Use Light key to display time
or enter Programming menu
by pressing and holding key. In
Programming mode,
the following parameters can
be set: time, filter cycle start
time, filter cycle frequency, and
temperature unit.

1716
in.clear
in.clear
bromine based water sanitation system
user instructions and functions
instruction video: www.gecko.com/inclear

1918
in.clear in.clear
•The cell is installed after the heater in the circulation pump line.
• The appliance must be installed in a location that is inaccessible
to a person in the bath or spa and must be located or fixed so
that it cannot fall into the bath or spa.
• The appliance is not intended for submersion but may be
installed within the spa zone.
• A means for disconnection must be incorporated in the fixed
wiring in accordance with the wiring rules.
• To reduce the risk of injury, do not allow children to operate
this device.
• It is the responsibility of the user to test the spa water regularly
to ensure that adequate amounts of bromine are generated to
achieve proper sanitizer levels.
• Heavy spa usage may require higher bromine output to maintain
proper free available bromine residuals.
• Maintaining overly high Sodium Bromide and bromine levels
above recommended range can contribute to corrosion of spa
equipment and may damage components of the spa.
• Do NOT use any ozone or UV sanitizer.
Warnings!
Important safety instructions
• Check the expiry date of the test kit as test results may be
inaccurate if used after that date.
• Follow all aspects of the local and National Electrical Code(s)
when installing the in.clear™ Automatic Bromine Generator.
• People with a medical condition should consult a physician
before entering spa water.
• Women who are pregnant should NOT enter the spa.
• Maximum spa water usage temperature is 40°C. Bathing in spa
water at 40°C should not exceed 15 minutes.
• For proper sanitation, Spas must be completely drained
periodically. The number of days between COMPLETE SPA
DRAINAGE is equal to the volume of the Spas water in liters,
divided by 10 times the maximum number of daily spa users.
Refill spa with water and repeat DIRECTION FOR USE of the
device.
- For a 1500 liters (400 US gallons) spa used by 2 adults twice a
week: 1500 / (10 x (4/7)) = 262 days or 8 months
• In.clear™ is meant for a covered spa NOT swimming pools.
• Users should always shower before entering a spa.
warnings
Warnings!
Important safety instructions
• For Canada, in.clear™ must only be used with Sodium Bromide
(such as BromiCharge™) scheduled or registered under the Pest
Control Product Act. For USA, the Sodium Bromide (such as
BromiCharge™) must be registered under EPA.
• Read and follow this manual carefully and make sure to save it
for later.
• This manual contains important information on in.clear's
installation, use and safety recommendations. It is your
responsibility to install and use your in.clear™ unit safely.
• In.clear™ must be connected to a circuit protected by a ground
fault interrupter device (GFCI) in North America or residual
current device (RCD) having a rated residual operating current
not exceeding 30 mA in Europe.
• Make sure all electrical power is off before installing the in.clear™
unit. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
• Use only an electrical cord in good conditions to power
in.clear™.
• Always clean or replace your filter cartridges at regular intervals,
otherwise part of the bromine generated by in.clear™ will only
serve to oxidize the dirt accumulated in the filter.
• Do NOT add any other sanitation chemicals in the spa other than
registered Sodium Bromide (such as BromiCharge™)
• Operating the in.clear™ at reduced Sodium Bromide (such as
BromiCharge™) levels will shorten the life of the cell.
• Do not open the in.clear™ unit; there are no serviceable parts
inside.
• Disposal of the product: the in.clear™ unit must be disposed
of separately in accordance with the local waste disposal
legislation in force.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
• To reduce the risk of injury, do not allow children to operate this
device.
• In.clear™ may not be suitable for in ground spas, it may affect
some materials used in their construction.
warnings
This manual suits for next models
3
Table of contents
Other Gecko Spa Accessories manuals

Gecko
Gecko S-CLASS 0202-205162 Technical manual

Gecko
Gecko BAHAMA SPAS Reference guide

Gecko
Gecko in.touch 2 User manual

Gecko
Gecko in.mix 300 Series User manual

Gecko
Gecko in.k1000 User manual

Gecko
Gecko in.k330 User manual

Gecko
Gecko M-CLASS MC-MP-SBD User manual

Gecko
Gecko in.ye-5 Technical manual

Gecko
Gecko Aeware3 in.touch User manual

Gecko
Gecko Y Series User manual