Gecko in.clear 0605-500002 User manual

In.Clear™ Model No. 0605-500002
Automatic Bromine Generator
For Spa Sanitizing
DOMESTIC
A maximum of 2000 Litres of water can be treated with one In.Clear Automatic Bromine
Generator unit.
Maximum output of Hypobromus Acid equivalent to 0.04 kg of free available bromine per day.
A range of 3 – 5 ppm of free available bromine must be maintained.
READ THE LABEL AND OPERATION/INSTALLATION MANUAL BEFORE USING THIS
DEVICE
KEEP OUT OF REACH OF CHILDREN
REGISTRATION No. 29628 PEST CONTROL PRODUCT ACT
WARNING:
Operating the In.Clear Automatic Bro mine Generator without water fow through the cell can
cause a build up of fammable gases which can result in FIRE or EXPLOSION.
NOTICE TO USER:
This pest control product is to be used only in accordance with the instructions shown on the
label. Any use not in accorda nce with these in structions is an offence under the Pest Control
Products Act. The u ser assumes the risk to pe rsons or property arising from the u se of this
product.
Tested and Listed to standards
ANSI/UL – UL 1081, UL 1563
CAN/CSA - C22.2 No. 108-1
Gecko Alliance Group Inc.
450, Des Canetons, Québec (Québec)
Canada G2E 5W6
800-784-3256 ext. 350
418-872-4411 ext. 350
2011-5850
2012-10-25

Page2
In.Clear™ Model No. 0605-500002
Automatic Bromine Generator
For Spa Sanitizing
DOMESTIC
A maximum of 2000 Litres of water can be treated with one In.Clear Automatic Bromine
Generator unit.
Maximum output of Hypobromus Acid equivalent to 0.04 kg of free available bromine per day.
A range of 3 – 5 ppm of free available bromine must be maintained.
READ THE LABEL AND OPERATION/INSTALLATION MANUAL BEFORE USING THIS
DEVICE
KEEP OUT OF REACH OF CHILDREN
REGISTRATION No. 29628 PEST CONTROL PRODUCT ACT
WARNING:
Operating the In.Clear Automatic Bro mine Generator without water fow through the cell can
cause a build up of fammable gases which can result in FIRE or EXPLOSION.
NOTICE TO USER:
This pest control product is to be used only in accordance with the instructions shown on the
label. Any use not in accorda nce with these in structions is an offence under the Pest Control
Products Act. The u ser assumes the risk to pe rsons or property arising from the u se of this
product.
Gecko Alliance Group Inc.
450, Des Canetons, Québec (Québec)
Canada G2E 5W6
800-784-3256 ext. 350
418-872-4411 ext. 350
CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A, GROUND FAULT
CIRCUIT INTERRUPTER. (GFCI)
SUITABLE FOR INDOOR USE ONLY OR WHEN INSTALLED UNDER A
WEATHERPROOF SPA SKIRT.
THIS UNIT MUST NOT BE INSTALLED IN PROXIMITY TO HIGHLY FLAMMABLE
MATERIALS.
CSA ENCLOSURE NUMBER 2.

Page3
In.Clear™ Model No. 0605-500002
Automatic Bromine Generator
For Spa Sanitizing
DOMESTIC
A maximum of 2000 Litres of water can be treated with one In.Clear Automatic Bromine Generator unit.
Maximum output of Hypobromus Acid equivalent to 0.04 kg of free available bromine per day.
A range of 3 – 5 ppm of free available bromine must be maintained.
READ THE LABEL AND OPERATION/INSTALLATION MANUAL BEFORE USING THIS DEVICE
KEEP OUT OF REACH OF CHILDREN
REGISTRATION No. 29628 PEST CONTROL PRODUCT ACT
WARNING: Operating the In.Clear Automatic Bromine Generator without water fow through the cell can cause a buildup
of fammable gases which can result in FIRE or EXPLOSION.
NOTICE TO USER:
This pest control product is to be used only in accordance with the instructions shown on the label. Any u se not in accordance with
these instructions is an offence under the Pest Control Products Act. The user assumes the risk to persons or property arising from
the use of this product.
Gecko Alliance Group Inc., 450, Des Canetons, Québec (Québec), Canada G2E 5W6
800-784-3256 ext. 350, 418-872-4411 ext. 350

Page4
table of contents
Table of contents
In.Clear™
introduction ...........................................................................................5
warnings ...............................................................................................6
bromine benefts - how In.Clear™ works ..............................................9
keypad installation ..............................................................................10
- installing the in.k200™ ....................................................................10
- skirt mount installation .....................................................................11
- connecting the in.k200™ to In.Clear™ .............................................12
In.Clear™ installation ...........................................................................13
operating modes .................................................................................16
getting started (see video) ..................................................................18
keypad operations ...............................................................................23
troubleshooting ....................................................................................27
F.A.Q....................................................................................................30
glossary ...............................................................................................31
cell cleaning..........................................................................................33
specifcations .......................................................................................35

Page5
introduction
In.Clear™
Water sanitation systems for spas
With its waterproof enclosure, its sturdy design, the new In.Clear™ is the most efficient water sanitation system offered to
the spa and hot tub industry today.
In.Clear™ is a system that generates and releases bromine into the spa water to rapidly control and destroy any
microbiological contaminants such as waterborne bacteria, algaes, body chemicals, organic matter given off by spa
bathers and other organisms known to be linked to recreational water illnesses.
The new In.Clear™ system eliminates the need to add extra chemicals in the water to destroy unsightly pollutants and
achieves impeccable results. The In.Clear™ system does not produce any offensive odors, it rather reduces eye irritation
and it's easy to handle, making the In.Clear™ a good choice for hot tub sanitation.
Spas using the new In.Clear™ system need very little maintenance, and In.Clear™ can be easily installed on new or
existing spas.

Page6
Warnings
Warnings! Important safety instructions
• For Canada, In.Clear™ must only be used with sodium bromide (such as BromiCharge™) scheduled or registered under
the Pest Control Product Act. For USA, the source of sodium bromide (such as BromiCharge™) must be registered
under EPA.
• Read and follow this manual carefully and make sure to save it for later.
• This manual contains important information on In.Clear's installation, use and safety recommendations. It is your
responsibility to install and use your In.Clear™ unit safely.
• In.Clear™ must be connected to a circuit protected by a ground fault interrupter device (GFCI) in North America or
residual current device (RCD) having a rated residual operating current not exceeding 30 mA in Europe.
• Make sure all electrical power is off before installing the In.Clear™ unit. If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent or similarly qualifed persons in order to avoid a hazard.
• Use only an electrical cord in good condition to power In.Clear™.
• Always clean or replace your flter cartridges at regular intervals, otherwise part of the bromine generated by In.Clear™
will only serve to oxidize the dirt accumulated in the flter.
• Do NOT add any other sanitation chemicals in the spa other than registered sodium bromide (such as BromiCharge™)
• Operating the In.Clear™ at reduced sodium bromide (such as BromiCharge™) levels will shorten the life of the cell.
• Do not open the In.Clear™ unit; there are no serviceable parts inside.
• Disposal of the product: the In.Clear™ unit must be done separately in accordance with the local waste disposal
legislation in force.

Page7

Page8
Warnings
Warnings!
• This unit is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction concerning use of the unit by a person responsible
for their safety.
• To reduce the risk of injury, do not allow children to operate this device.
• In.Clear™ may not be suitable for in ground spas, it may affect some materials used in their construction.
• The unit must be installed in a location that is inaccessi ble to a person in the bath or spa and must be located or fxed so
that it cannot fall into the bath or spa.
• The unit is not intended for in-ground spas as it may affect certain materials used in the spa’s construction.
The unit is not designed to be submersed but may be installed underneath the waterproof skirt of the spa.
• A means for disconnection must be incorporated in the fxed wiring in accordance with the wiring rules.
• Do not add chemical products for pool or spa directly into the skimmer. This may damage the cell.
• It is the responsibility of the user to test the spa water regularly to ensure that adequate amounts of bromine are
generated to achieve proper sanitizer levels.
• Heavy spa usage may require higher bromine output to maintain proper quantity of free available bromine.
• The expected life time of the electrodes is 30 000 hours when used in normal operating conditions.

Page9
Warnings
Warnings!
• • Maintaining overly high sodium bromide and bromine levels above recommended range can contribute to corrosion of
spa equipment and may damage components of the spa.
• The cell is installed after the heater in the circulation pump line.
o Do NOT use any ozone or UV sanitizer.
• Check the expiry date of the test kit as test results may be inaccurate if used after that date.
• Follow all aspects of the local and Na tional Electrical Code(s) when installi ng the In.Clear™ Automatic Bromine
Generator.
• People with a medical condition should consult a physician before entering spa water.
• Women who are pregnant should NOT enter the spa.
• Maximum spa water usage temperature is 40°C. Bathing in spa water at 40°C should not exceed 15 minutes.
• For proper sanitation, spa must be completely drained periodically. The number of days between COMPLETE SPA
DRAINAGE is equal to the volume of the spa water in liters, divided by 10 times the maximum number of daily spa users.
Refll spa with water and repeat DIRECTION FOR USE of the device.
- For a 1500 liters (400 US gallons) spa used by 2 adults twice a week: 1500 / (10 x (4/7)) = 262 days or 8 months
• In.Clear™ is meant for a covered spa NOT swimming pools.
• Users should always shower before entering a spa.

Page10
Other manuals for in.clear 0605-500002
2
Table of contents