2
Safety Rules
1. To reduce the risk of electric shock, ensure electricity has
been turned off at the circuit breaker or fuse box before
beginning.
2. All wiring must be in accordance with the latest edition of
National Electrical Code “ANSI/NFPA 70” and local electrical
codes. Electrical installation should be performed by a
3. WARNING: To reduce the risk of fire, electric shock or
personal injury, do not use this fan with any solid state fan
speed control device, or variable speed control.
4. CAUTION: To reduce the risk of personal injury, use only
the screws provided with the outlet box.
5. The outlet box and support structure must be securely
mounted and capable of reliably supporting a minimum of
15.9 kg (35 lb.). Use only UL Listed outlet boxes marked “FOR
FAN SUPPORT.”
6. The fan must be mounted with a minimum of 2.1m (7 ft.)
clearance from the trailing edge of the blades to the r.
7. Avoid placing objects in the path of the blades.
8. To avoid personal injury or damage to the fan and other
items, be cautious when working around or cleaning the fan.
9. Do not use water or detergents when cleaning the fan or
fan blades. A dry dust cloth or lightly damped cloth will be
suitable for cleaning.
10. After making electrical connections, spliced conductors
should be turned upward and pushed carefully up into
the outlet box. The wires should be spread apart with
the grounded conductor and the equipment-grounding
conductor on one side of the outlet box and ungrounded
conductor on the other side of the outlet box.
11. All screws must be checked and re-tightened where
necessary during installation.
WARNING: To reduce the risk of
re, electric shock or personal
injury, mount fan to outlet box
marked acceptable for fan
support and use the screws
provided with the outlet box.
WARNING: To reduce the risk
of personal injury, do not bend
the blade arms (also referred
t
the brack
not insert for
between r
WARNING: To reduce the risk of
re, electric shock or personal
injury, mount to outlet box
marked “acceptable for fan
suppor b
less rews
provided with the outlet box.
Most outlet boxes commonly
used for the suppor
res are not acceptable for
fan support and may need to be
rto the complexity
of the installation of this fan, a
str recommended.
Read and Save These Instructions
12.This fan is suitable for room sizes up to 144 square feet
(13.38 square meters).

3
Basic Guidelines For Working With Electricity
1. Before working on a circuit, go to the main service panel
and remove the fuse or trip the breaker that controls that
circuit.
2. Tape a sign to the panel warning others to leave the circuit
alone while you work.
3. Before touching any wire, use a voltage tester to make
sure it’s not live.
4. Whenever you check for voltage in a receptacle, check
both outlets; each may be controlled by a separate wiring
circuit.
5. When replacing fuses, turn off the main power ¿rst. Make
sure your hands and feet are dry, and place one hand behind
your back to prevent electricity from making a complete
circuit through your chest. Touch a plug fuse only by its
insulated rim.
6. Remove cartridge fuses with fuse puller.
7. Use tools with insulated handles and ladders made of
wood or ¿berglass.
8. To protect children, place safety cover over any unused
outlets.
Shut off main
power at the
circuit breaker
or fuse panel
before removing
old ¿[ture.
Remove
old ¿[ture.
Disconnect wire.
5,,
MAIN
POWER

4
To Begin / Tools Needed (Not Supplied)
REQUIRED
Flathead
Screwdriver
Pliers
Step Ladder
Phillips Screwdriver
(4" recommended)
Wire Cutters
Wire Strippers
Safety Glasses
Electrical Tape
Soft Cloth

5
Hardware Included
Carefullyunpack and identifyeach part to make sure you
have everything readyfor installation. Layout each part on
a clean at area such as a table or oor. Check to make sure
you have the following:
A
A
2
E
E
2
I
I
1
C
C
2
G
G
12+1
12+1
K
M
2
N
P
2
B
B
2
F
F
J
L
1
M
O
1
D
D
2
H
H
4
L
N
1
O
Q
6
Hardware Bag Remote Control
PART DESCRIPTION
Wood Screw (Long)
Spring Washer
Fiber Washer
Transmitter
Receiver (pre-installed
inside fan motor assembly)
Mounting Screw
Flat Washer
Plastic Wire Nut
AAA Battery
Wood Screw (Short)
Star Washer
Blade Screw
Balance Kit
Transmitter Holder
Plastic Wire Nut
QUANTITY
+
-
J
K
P
Q
Rubber Washer (4mm)
Rubber Washer (7mm)
2
2
ATTENTION: Parts are not to scale.
NOTE: +1 = Extra quantity supplied
for future use if needed.

6
Package Contents
Carefully unpack and identify each part to make sure you
have everything ready for installation. Lay out each part on
a clean at area such as a table or oor. Check to make sure
you have the following:
R4
V1
1
4
Z3
T1
X
S1
W
U1
Y3
PART DESCRIPTION
Set Of Blades
Mounting Plate
Canopy Mounting
Screw (pre-installed)
Mounting Plate Screw
(pre-installed)
Light Kit Mounting
Screw (pre-installed)
powerplug receptacle
LED light kit
Fan Motor Assembly
Glass Shade
QUANTITY
R
V
Z
T
X
S
W
U
Y
Functional Fasteners
ATTENTION: Parts are not to scale.

7
Fan Installation Drawing
WARNING: review important safety instructions before installation.
Outlet Box (Not Provided)
Wood Screw (Long)
Powerplug receptacle
Black Wire
Flat Washer
Ground Wire
Neutral White Wire
Spring Washer
Mounting Screw
Canopy Mounting Screw
Blade
Fiber Washer
Blade Screw
Mounting Plate Screw
LED Light Kit
Glass Shade
Light Kit Mounting Screw
Mounting Plate
Fan Motor Assembly
Canopy Ring
J Slot
Rubber Washer
Star Washer

Fan Installation
WIRING DIAGRAM 1:
Typical Wiring Configuration for 1 Wall Switch
white
green
black (live)
(L1)
(L2)
W
G-ground
WIRING DIAGRAM 2:
Typical Wiring Configuration for 2 Wall Switches
red (live 2)
WHITE
white
green
black(live 1)
(L1)
(L2)
W
G-ground
This Fan is supplied with a remote control receiver
and transmitter to operate the fan and light. The
L2 terminal is not activated on this fan. The red wire
can be capped off with a wire nut or inserted into L2.
Only 1 wall switch will be operational.
8
Prepare wiring from outlet box. Be sure there are no
deep cuts in the exposed copper wiring as it could
break off in the terminals. Cut and strip 1/2 in. of
insulation from end of each wire if neccessary. (Fig 1)
NOTE: Do NOT strip any more than 1/2 in. of insulation
from end of wires as this could cause a short at any
time.
IMPORTANT: Wiring must not come down and around
the face of powerplug receptacle.
Connect GREEN/BARE wire from ceiling to terminal in
powerplug receptacle marked G. Secure the wire by
tightening the small set screw.
Reference the wiring configuration diagrams below for
other wiring options into the terminal. L1 is the only
active live terminal on this fan.
Fig 2
Fig 1
powerplug -
receptacle
ground
(green/
bare)
wire
white
wire
black wire
black wire
G
W
L1
Fig 3
L1
ground
black
L1 W
G
white wire
green/bare
wire
whi te
outlet box
L2
red
(CLOSE-UP VIEW of TERMINALS on Powerplug Receptacle)
NOTE: If you do not have standard wiring configurations
and have questions about the wiring in your outlet box,
please contact a qualified electrician.
Electrical wiring (refer to Fig 2 and Fig 3 as necessary)
Connect BLACK wire from ceiling to terminal in
powerplug receptacle marked L1. Secure the wire by
tightening the small set screw.
Connect WHITE wire from ceiling to terminal in
powerplug receptacle marked W.Secure the wire by
tightening the small set screw.
can be made as follows:
MAKING THE ELECTRICAL CONNECTIONS

Fan Installation
WIRING DIAGRAM 3:
Wiring Configuration with more than 1 of the same
the outlet box
white
green
black
(L1)
(L2)
W
G-ground
WIRE NUT
white
When multiple wires are connected together, use a
solid wire 12-14 AWG jumper lead to insert into the
receptacle terminal.
NOTE: Be sure to push each wire from ceiling all the
way into corresponding terminal on powerplug. If
wire is not inserted completely, there is a possibility
that the electrical connection will fail. If you have
multiple wires connected together, add a jumper lead
and insert jumper lead into terminal. One single wire
is inserted into terminal.
9
colored wires in
Q
B
E
2.
Rubber Washer
Install powerplug receptacle (Q) to outlet box
using the mounting screws (with lock washer)
(BB) and flat washers (CC) provided with the
outlet box. (Two additional mounting screws
(with lock washer) (BB) and flat washers (CC)
are provided in the hardware bag).
The placement of the powerplug
receptacle on the ceiling is important for the
fan plug to make the correct installation and
securement. The powerplug receptacle should
be evenly flush with the ceiling. Use the rubber
washers as shown in the figures on next page.
NOTE:
WARNING: To avoid possible
electric shock, be sure electricity is
turned off at the main fuse box
before wiring.
NOTE: Fan must be installed at
a maximum distance of 6 m (20
ft.) from the transmitting unit for
proper signal transmission between
the transmitting unit and fan’s
receiving unit.
CAUTION : Do not use wall switch
with dimmer function.
View Installation Video@
www.gelightingandfans.com
INSTALLING THE POWERPLUG RECEPTACLE
1.
Use metal outlet box (sold separately) suitable
for fan support. Secure outlet box directly to
the building structure using wood screws (A)
and star washer (C). Outlet box must support
(35 lb.) min.
DANGER: A loose outlet box can cause the
fan to wobble and increase the fan’s
potential to fall, which could result in
serious injury or death.
C
C
A
A
WARNING : Do not use an existing
mounting bracket in the outlet box,
replace it with the powerplug
receptacle that is included with the
fan.

Fan Installation
10
INSTALLING THE POWERPLUG RECEPTACLE WITH RUBBER WASHER
It is important for the powerplug receptacle to be flush with the ceiling surface. Outlet boxes are typically
not even with the surface or sheet rock and the rubber washers will help to reduce or eliminate the gap.
Follow these instructions. The washer size is marked on the bag.
Fig 1. Outlet box is flush with the ceiling or the
gap is less than 1.5mm, use 4mm rubber washer
provided. Place the washer above the powerplug
receptacle as shown.
Fig 3. Outlet box and the ceiling with gap from
3mm to 5mm, use both 4mm and 7mm rubber
washers provided. Place the washer above the
powerplug receptacle as shown.
4mm rubber washer
0-1.5mm
1.5-3mm
7mm rubber washer
4mm rubber washer >3mm
7mm rubber washer
Fig 2. Outlet box and ceiling with gap is more than
1.5mm but less than 3mm, use the 7mm rubber
washer provided. Place the washer above the
powerplug receptacle as shown.
Fig 1.
Fig 2.
Fig 3.
Other manuals for 20444
1
This manual suits for next models
2
Table of contents
Languages:
Other GE Fan manuals
Popular Fan manuals by other brands

ELTA FANS
ELTA FANS H03VV-F installation guide

Hunter
Hunter 20714 Owner's guide and installation manual

Emerson
Emerson CARRERA VERANDA CF542ORB00 owner's manual

Hunter
Hunter Caraway Owner's guide and installation manual

Panasonic
Panasonic FV-15NLFS1 Service manual

Kompernass
Kompernass KH 1150 operating instructions