Furuno FSS-3BB User manual

www.furuno.com
A
ll brand and product names are trademarks, registered trademarks or service marks of their respective holders.
Installation Manual
FISH SPECIES AND BIOMASS SOUNDER
Model FSS-3BB
(Product Name: FISH FINDER)
SAFETY INSTRUCTIONS ................................................................................................ i
SYSTEM CONFIGURATION .......................................................................................... iii
EQUIPMENT LISTS........................................................................................................ iv
1. MOUNTING..............................................................................................................1-1
1.1 Processor Unit ...................................................................................................................1-1
1.2 Transceiver Unit.................................................................................................................1-3
1.3 Trackball Control Unit ........................................................................................................1-4
1.4 Transducer.........................................................................................................................1-7
1.5 DVI/USB Repeater (Option)...............................................................................................1-9
1.6 Monitor Unit (Local Supply)..............................................................................................1-11
2. WIRING....................................................................................................................2-1
2.1 Processor Unit ...................................................................................................................2-2
2.2 Transceiver Unit.................................................................................................................2-6
2.3 Trackball Control Unit ......................................................................................................2-10
2.4 DVI/USB Repeater (Option).............................................................................................2-12
2.5 Input/Output Sentences (NMEA0183) .............................................................................2-14
3. INITIAL SETTINGS..................................................................................................3-1
3.1 Initial Setting Menu ............................................................................................................3-1
3.2 How to Set the Service Menu ............................................................................................3-5
3.3 Communication Port Setting ............................................................................................3-11
3.4 [Calibration] Menu............................................................................................................3-13
3.5 [Stabilization] Menu..........................................................................................................3-15
3.6 How to Take a Still Image of the RX Monitor...................................................................3-17
3.7 Model Data for the IDENTI-FISH™Graph .......................................................................3-17
3.8 Reset to Default Setting...................................................................................................3-18
APPENDIX 1 JIS CABLE GUIDE .............................................................................AP-1
PACKING LISTS ......................................................................................................... A-1
OUTLINE DRAWINGS ................................................................................................ D-1
INTERCONNECTION DIAGRAMS.............................................................................. S-1

The paper used in this manual
is elemental chlorine free.
・FURUNO Authorized Distributor/Dealer
9 52 Ashihara cho,
Nishinomiya, 662 8580, JAPAN
A
:
APR
2020
.
Printed in Japan
All rights reserved.
A1
:
MAY
26, 2020
Pub. No.
IME-23930-A1
(
REFU
)
FSS-3BB
0 0 0 1 9 7 1 4 4 1 0

i
SAFETY INSTRUCTIONS
The installer must read the safety instructions before attempting to install the equipment.
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment unless
totally familiar with electrical circuits
and service manual.
Only qualified personnel are allowed to
work inside the equipment.
Mandatory Action
Prohibitive Action
WARNING
CAUTIOCAUTION
Warning, Caution
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided,
could result in minor or moderate injury.
CAUTION
Ground the equipment to prevent
mutual interference.
Standard
compass
Steering
compass
Turn off the power at the switchboard
before beginning the installation.
Fire or electrical shock can result if the
power is left on.
For wooden or FRP vessel using a
steel tank, attach a zinc plate to the
hull to prevent electrolytic corrosion.
Electrolytic corrosion can, in the worst
case, result in loss of the transducer.
Install the transducer according to the
installation instructions.
Failure to install the transducer correctly
may result in water leakage and damage
to the ship’s hull.
Be sure no water leaks in at the
transducer mounting location.
Water leakage can sink the vessel. Also,
confirm that vibrations will not loosen the
transducer. The installer of the equipment
is solely responsible for the proper
installation of the equipment. FURUNO
will assume no responsibility for any
damage associated with improper
installation.
Use the proper cable and fuse.
Use of an incorrect cable and fuse can
damage the equipment and cause fire.
Do not transmit with the transducer
out of water.
The transducer may become damaged.
Observe the following compass safe
distance to prevent interference to a
magnetic compass:
Unit
Processor Unit
(FSS-301)
Transceiver Unit
(FSS-302)
Trackball Control Unit
(RCU-026)
2.15 m 1.35 m
1.95 m 1.20 m
0.30 m 0.30 m
DVI/USB Repeater
(
TM000-FDX06
)0.35 m 0.30 m

SAFETY INSTRUCTIONS
ii
CAUTION
The transducer cable must handled
carefully, following the guidelines
below.
- Keep the cable away from oil and fuels.
- Keep the cable away from locations
where it may be damaged during the
installation.
- Do not paint the cable.
The cable sheath is made of chloro-
prene or vinyl chloride, which are easily
damaged by plastic solvents such as
toluene. Locate the cables away from
plastic solvents.
- Do not shorten the transducer cable.
- Do not carry the transducer using only
the cable.
The cable may become damaged or
disconnected.
Do not cover the transducer with FRP
resin.
The heat generated when the resin
hardens may damage the transducer.
Do not install the transducer on the
inner side of the hull.
The signal strength is reduced and may
affect the accuracy of measurements.

iii
SYSTEM CONFIGURATION
Note: The sub monitor cannot display the same screen as the main monitor.
: Standard supply
: Optional/local supply
Monitor Unit
*3
Processor Unit
FSS-301
USB Device
*2
HDMI
2 ports
NMEA0183
5 ports
USB
USB3.0: 2 ports
USB2.0: 2 ports
USB Device
*1,
*3
(USB Mouse,
USB Flash Memory,
External HDD, etc.)
Trackball Control Unit
RCU-026
Trackball Control Unit
RCU-026
RS-485
USB
*2
RS-485
USB
*2
*1
: A maximum of four USB devices including RCU-026 can be connected to the processor unit.
*2
: To use the USB port on the RCU-026, connect the RCU-026 to the USB port on the processor unit, using
the USB cable supplied with the RCU-026. If you do not use the USB port on the RCU-026, the USB
connection between the RCU-026 and processor unit is not required.
*3
: To extend the distance between the processor unit and the monitor unit/USB device, use the optional
DVI/USB repeater.
LAN
Transceiver Unit
FSS-302
Transducer
USB Device
*2
Navigation equipment,
Radio communication,
Net sonde, etc.
12-24 VDC
100/110/115/220/230 VAC,
1
Ø
, 50/60 Hz
Rectifier
RU-1746B-2
12-24 VDC
100/110/115/220/230 VAC,
1
Ø
, 50/60 Hz
Rectifier
RU-1746B-2
External KP

iv
EQUIPMENT LISTS
Standard Supply
Option
Name Type Code No. Qty Remarks
Processor Unit FSS-301 - 1
Transceiver Unit FSS-302 - 1
Trackball Control Unit RCU-026 - 1
Installation Materials
CP10-09700 000-036-275 1 For processor unit
CP02-09700 000-037-337 1 For transceiver unit
CP24-02300 000-027-673 1 For trackball control unit
Accessories FP24-00801 001-418-410 1 For trackball control unit
Spare Parts SP26-00301 001-080-860 1 For processor unit
SP02-05901 001-568-430 1 For transceiver unit
Name Type Code No. Remarks
Transducer CM265LHG - For details about transducer
specifications, see page 1-8.
CM265LM -
CM275LHW -
CM599LHG -
CM599LM -
CM599LHW -
PM111LHG -
PM111LM -
PM411LWM -
Trackball Control
Unit RCU-026 -
Rectifier Unit RU-1746B-2 -
DVI/USB Repeater TM000-FDX06_TXRX_30M - Transmitter and receiver units
with LAN cable (30 m)
TM000-FDX06_TXRX_50M - Transmitter and receiver units
with LAN cable (50 m)
TM000-FDX06_TXRX100M - Transmitter and receiver units
with LAN cable (100 m)
TM000-FDX06_TXRX - Transmitter and receiver units
TM000-FDX06_RX - Transmitter unit
TM000-FDX06_TX - Receiver unit
Flush Mount OP24-27 001-171-820 For RCU-026
Cable Assembly HDMI-TO-DVI-L=5.3M 001-407-180 DVI-HDMI cable 5.3 m
HDMI-TO-DVI-L=10.3M 001-407-170 10.3 m
6TPSH-XH12X2-L5.0SP2 001-186-310-10 For RCU-026 5 m
6TPSH-XH12X2-L10SP2 001-186-320-10 10 m
MJ-A3SPF0024-035C 000-157-943-10 Power cable for
DVI/USB repeater
3.5 m
RNS-08-132 001-107-540-10 USB cable for the
transmitter unit of
the DVI/USB re-
peater
5 m

EQUIPMENT LISTS
v
Cable Assembly PARTS_WO2511 001-578-140 LAN cable for DVI/
USB repeater
30 m
PARTS_WO2512 001-578-150 50 m
PARTS_WO2513 001-578-160 100 m
Extension Cable C44-02 30M 001-374-620 For transducer 30 m
C44-02 50M 001-374-580 50 m
Installation
Materials
CP10-10100 000-036-244 LAN cable 10 m
CP10-10110 000-036-245 15 m
CP10-10120 000-036-246 30 m
CP10-10130 000-036-247 40 m
CP10-10140 000-036-248 50 m
CP10-10150 000-036-722 100 m
Name Type Code No. Remarks

EQUIPMENT LISTS
vi
This page is intentionally left blank.

1-1
1. MOUNTING
1.1 Processor Unit
The processor unit can be installed on a deck or bulkhead.
Mounting considerations
Select a mounting location, keeping in mind the following points:
• Locate the unit out of direct sunlight and away from heat sources.
• Locate the unit away from places subject to water splash and rain.
• Select a mounting location considering the length of the cables to be connected to
the unit.
• Select a location where shock and vibration are minimal.
• Be sure the mounting location is strong enough to support the weight of the unit.
• Referring to the outline drawings at the back of this manual, allow sufficient space
for maintenance and service.
• A magnetic compass will be affected if the unit is placed too close to the magnetic
compass. Observe the compass safe distances at the front of this manual to prevent
interference to a magnetic compass.
• For bulkhead installations, secure the unit so that the cable entrance faces down-
ward.
NOTICE
Do not apply paint, anti-corrosive sealant or contact
spray to coating or plastic parts of the equipment.
Those items contain organic solvents that can damage
coating and plastic parts, especially plastic connectors.

1. MOUNTING
1-2
1.1.1 Deck mount
1. Drill four pilot holes in the mounting location for mounting bolts, referring to the
outline drawing at the back of this manual.
2. Secure the unit using the four hex head slot bolts (M6×20, supplied).
1.1.2 Bulkhead mount
1. Drill four pilot holes in the mounting location for mounting bolts (M6×20, supplied),
referring to the outline drawing at the back of this manual.
2. Screw the two hex head slot bolts into the lower pilot holes. Leave 5 mm of thread
visible.
3. Set the notches of the unit onto the bolts fastened at step 2.
4. Screw the two hex head slot bolts into the upper fixing holes.
5. Fasten all bolts tightly to secure the unit in place.
Hex head slot bolt
(M6×20, 4 pcs䠅
Detailed view
Set the notches of the unit
to the bolts.
Hex head slot bolt
(M6×20, 4 pcs䠅
Other manuals for FSS-3BB
1
Table of contents
Other Furuno Fish Finder manuals

Furuno
Furuno BBFF3 Owner's manual

Furuno
Furuno DFF1-UHD User manual

Furuno
Furuno FCV-600 User manual

Furuno
Furuno FCV-627 User manual

Furuno
Furuno DFF1-UHD User manual

Furuno
Furuno FCV-587 User manual

Furuno
Furuno DFF3-UHD User manual

Furuno
Furuno FCV-1900G User manual

Furuno
Furuno FCV-2100 User manual

Furuno
Furuno FCV-288 User manual

Furuno
Furuno FCV-1900 User manual

Furuno
Furuno FCV-628 User manual

Furuno
Furuno FCV-1900/B/G User manual

Furuno
Furuno FCV-627 User manual

Furuno
Furuno FSS-3BB User manual

Furuno
Furuno FCV-627 User manual

Furuno
Furuno BT-5 User manual

Furuno
Furuno FCV-627 User manual

Furuno
Furuno FE-4000 User manual

Furuno
Furuno FCV-2100 User manual