Frigicoll Kaysun KCCHT-03 User manual

CONTROL
KCCHT-03
Original instructions
Thank you very much for purchasing our air conditioner,
Before using your air conditioner, please read this manual carefully and keep it for future
reference.
OWNER'S MANUAL


CONTENTS
1. Safety precautions.................................................................................1
2. Technical data and characteristic...........................................................1
3. Overview................................................................................................2
4. Operation instruction..............................................................................5
5. Error handling......................................................................................17

• This manual gives detailed description of the precautions that should be brought
to your attention during operation.
• In order to ensure correct service of the wired controller please read this manual
carefully before using the unit.
• For convenience of future reference, keep this manual after reading it.

1
1. Safety precautions
WARNING
• Please assign the distributor or professionals to install the device. Improper insta-
llation may lead to electric shock or re.
• Do not install the unit in a place vulnerable to leakage of ammable gases. Once
ammable gases are leaked and left around the wire controller, re may occur.
• Do not operate with wet hands or let water enter the wire controller. Otherwise,
the device lifespan will be shortened.
2. Technical data and characteristic
2.1 Technical data
1) Input voltage: 10VAC.
2) Operating environment temperature of wired controller: -10°C~+43°C.
3) Operating RH of wired controller: RH 40%~RH 90%.
2.2 Characteristic
1) Touch key operation;
2) LCD displays operation parameters;
3) Multiple timer;
4) Real-time clock (battery life:5~8 years).

2
3. Overview
1
2
3
4
16
11
15
1. Operation icon
2. Mode area
3. Setting temperature
4. Timing On/Off
5. Function Icon
6. Unit number
7. Water Level Indica-
tion (reserved)
8. Clock
9. Water temp. 10.ON/
OFF Key 11.Left / Right Key
12. OK Key
13. Function key
14. Add and Reduce key
15. Cancel key
16. Mode key
5
6
7
8
9
10
11
12
14 13
MODE
FUNCTIONS
(Long press 3s for can-
celling timing)
(Long press 3s for un-
locking)

3
1 Operation icon: Indicate unit ON and OFF status; the icon displays when the unit
is on and does not display when the unit is off;
2 Mode area: Indicate the main unit operating mode; details refer to Page 7;
3 Water temperature: 2 status can be displayed:;
4 Timing ON/OFF indication: Indicate the timing information; details refer to Page 9;
5 Function icon
1) : Displays when the unit controlled by remote switch;
2) : Displays when the unit operation forced cooling mode;
3) : Displays when the unit is needed. Press and hold “MODE” key for 3 seconds to
cancel the icon and timing will restart until next maintenance;
4) : The reserved icon;
5) : The reserved icon;
6) : Displays when check function is on; details refer to Page 17;
7) : Displays when ambient temperature is low which means the main
unit need anti-freezing action;
8) : Displays when no key operation for 2 minutes and all keys are locked.
Press and hold “OK” key for 3 seconds to unlock;
9) : Displays when error or protection occurs and means the unit need maintainence
by professionals.
6 The unit number: The user can set the number,details refer to Page 15;
7 Water level indication: The reserved icon;
8 Clock: Under normal status displays clock; Under timing setting displays the setting
timing, details refer to Page 14;

4
9 Water temperature: Under normal status display water temperature; Under water
temperature setting status displays the setting value; Under check status displays check
parameter, details refer to Page 8;
10 ON/OFF key: Turn on and turn off functions, details refer to Page 6;
11 Right and Left key: Press these keys to check setting water temperature; Press
right key to shift to the next step setting under timing setting status; Press these keys to
turn over the unit parameter information under check status;
12 OK key: Press this key to conrm settings. Press and hold this key for 3 seconds to
unlock under locking status;
13 Function key: Setting water temperature, timing and clock etc, details refer to
Page 9-19; Press and hold this key for 3 seconds to enter check status, details refer to
Page 17; setting unit number details refer to Page 15 forced open water pump details refer
to Page 16.
14 Add and Reduce key: Move up or move down values of temperature, timing etc;
15 Cancel key: Press this key to cancel parameter setting under setting status; Press
and hold this key for 3 seconds to cancel timing when timing is valid;
16 Mode key: Power on the cooling function,heating function or water pump function,
details refer to Page 7.

5
4. Operation instruction
4.1 Turn On and Turn Off the main unit
1) Press the On/Off key to control On and Off status of the main unit.
2) Under Off status, press the On/Off key “ ” to run the main unit, at that time the LCD
of wire controller will display the operation icon “ ”. The main unit will running as the
current setting of the wire controller.
3) Under On status, press the On/Off key “ ” to turn off the main unit and the operation
icon “ ” on the LCD will disappear.
NOTE
• When outdoor unit is in restore-to-factory- default setting mode(outdoor unit dis-
plays ”OFF”),
wire controller won’t start the unit. Quit “OFF” status through outdoor unit display
operation panel.
• If outdoor unit is forced shutdown by remote control, then the unit won’t start by
using wire controller. Relieve the unit from shutdown status by remote control.
(Long press 3s for
cancelling timing)
(Long press 3s for
unlocking)
Press one time
Fig.4.1

6
4.2 Setting operating mode and function parameters
4.2.1 Setting operating mode and water temperature
1) Setting operating mode
Press “MODE” key to choose operation mode. The setting mode will change as the fo-
llowing order each time the key is pressed:
Press “OK” key or wait for 7 seconds to conrm.During the setting process pressing the
“CANCEL” key to exit without saving
2) Setting water temperature
Method 1:Press the “▲” or “▼” to adjust the water temperature under main interface.
Press “OK” key or wait for 7 seconds to conrm.
Method 2:Setting water temperature in funciton parameters.Press “FUNCTIONS” key un-
der main interface once to enter water temperature setting interface.Press the “▲” or “▼”
to adjust the water temperature .Press “OK” key or wait for 7 seconds to conrm.
Fig 4.2
(Long press 3s for
cancelling timing)
(Long press 3s for
unlocking)
Table of contents