Franke UT 40 CM User manual

20170648Original operating instructions
Original operating instructions • 20170648 • 01 • 8/11/2020
en
USER MANUAL
UT40 CM AND PUMP MODULES
FCS4076 / FCS4072

Read the user manual before working on the equipment.
Keep the manual with the equipment and pass the manual on to the next
user if the equipment is sold or transferred to a third party.

Franke Kaffeemaschinen AG Table of contents
iii / 24
TABLE OF CONTENTS
1 For your safety ............................................................................................ 4
1.1 Intended use ............................................................................................... 4
1.2 Non-authorized use ..................................................................................... 4
1.3 General safety concerns .............................................................................. 5
2 Scope of delivery....................................................................................... 10
3 Identification ............................................................................................. 11
3.1 Position of type plates ............................................................................... 11
4 Instructions ............................................................................................... 12
4.1 Components of the cooling unit with Franke containers and plug-in couplings
................................................................................................................. 12
4.2 Cooling unit UT40 FM CM with pump module(s)......................................... 13
4.3 Function of the cooling unit ....................................................................... 14
4.4 Pump module functions ............................................................................. 14
4.5 Operation and care.................................................................................... 15
4.6 Malfunctions ............................................................................................. 15
4.7 Transport, storage, decommissioning......................................................... 16
4.8 Disposal .................................................................................................... 17
5 Technical data for UT40 CM ...................................................................... 18
Index......................................................................................................... 20

1 | For your safety Franke Kaffeemaschinen AG
4 User manual UT40 CM and Pump Modules
1 FOR YOUR SAFETY
1.1 Intended use
– The cooling unit is intended exclusively for use in enclosed furniture with
ventilation openings to prevent liquids from entering the unit. The cooling
unit must never be used free-standing.
– The cooling unit is intended exclusively for operation indoors.
– The cooling unit is designed exclusively to keep milk and ready-to-drink
beverages cool for the preparation of beverages with a Franke coffee ma-
chine.
– Only use pre-cooled milk and pre-cooled ready-to-drink beverages.
– Remove the milk and ready-to-drink beverages when the cooling unit is
not in use. Store milk and ready-to-drink beverages in a suitable cooling
unit.
– Only use the cooling unit at ambient temperatures of 10–43 °C.
– Use only the recommended cleaners. Other cleaners may leave residues
in the milk and beverage system.
– Please also observe the Declaration of Conformity delivered with the de-
vice.
1.2 Non-authorized use
– Children under the age of 8 years are not permitted
to use the device.
– Children or persons who are challenged with respect
to physical, sensory or mental abilities must not use
the device except under supervision, nor should they
play with the device.

Franke Kaffeemaschinen AG For your safety | 1
User manual UT40 CM and Pump Modules 5
– Alcoholic, flammable, explosive substances or spray cans must not be
used or stored in the device.
– Do not place or use any electrical appliances inside the cooling unit.
– Do not use the machine:
– If you are not familiar with its functions.
– If the machine, power cord or connection lines are damaged.
– If the machine has not been cleaned or filled as specified.
1.3 General safety concerns
WARNING
Risk of fatal injury from electrocution
Damaged power cords, pipes or push-on fittings can lead to electrocution.
a) Do not connect any damaged power cords, pipes or push-on fittings to
the power grid.
b) Replace damaged power cords, pipes or push-on fittings.
If the power cord is permanently assembled, contact the service techni-
cian. If the power cord is not permanently assembled, order and use a
new, original power cord.
c) Ensure that the machine and the power cord are not near any hot sur-
faces such as gas or electric stoves or ovens.
d) Ensure that the power cord is not pinched and does not chafe on sharp
edges.

1 | For your safety Franke Kaffeemaschinen AG
6 User manual UT40 CM and Pump Modules
WARNING
Risk of fire and explosion
R600a refrigerant is highly flammable. If it escapes, it presents a fire and ex-
plosion risk.
a) When transporting and installing the cooling unit, make sure that no part
of the refrigeration circuit is damaged.
b) Installation may only be performed by an authorized Franke specialist.
c) The appliance must be installed in a room with sufficient space.
d) Make sure that the air vents of the appliance and the closed cabinet in
which the appliance is installed are never blocked or obstructed.
e) Maintenance work may be performed by qualified service personnel only.
f) Do not use the appliance if it exhibits any signs of damage.
g) To avoid damaging the refrigeration circuit, do not use mechanical de-
vices or any other means to accelerate the defrosting process.
h) Never use jets of water or harmful substances to clean the cooling unit.
i) Do not expose the cooling unit to sources of heat.
j) In case of malfunction, disconnect the cooling unit from the power sup-
ply.
k) In case of refrigerant leaks, avoid any naked flames. Move anything
flammable away from the appliance and ventilate the room immediately.
l) In case of fire, use powder extinguishers.

Franke Kaffeemaschinen AG For your safety | 1
User manual UT40 CM and Pump Modules 7
WARNING
Risk of fire
If the power cord is electrically overloaded, the heat generated can cause a
fire.
a) Never use power outlet strips or extension cords to connect the device to
the power supply.
CAUTION
Irritation from cleaners
Cleaning tablets, milk system cleaning agents, and descaler can lead to irrita-
tions of the skin or eyes.
a) Observe the hazard warnings on the label of the respective cleaner.
b) Avoid contact with your eyes and skin.
c) Wash your hands after coming into contact with cleaners.
d) Cleaners must not find their way into drinks.
CAUTION
Spoiled milk and ready-to-drink beverages
Spoiled milk and spoiled ready-to-drink beverages could represent a health
hazard.
a) Use only fresh, refrigerated milk and fresh, refrigerated ready-to-drink
beverages.
b) Observe the storage conditions for milk and ready-to-drink beverages.
c) Observe the shelf life of the milk and ready-to-drink beverages used.

1 | For your safety Franke Kaffeemaschinen AG
8 User manual UT40 CM and Pump Modules
CAUTION
Germs in unpasteurized milk
Germs in unpasteurized milk could pose a health hazard.
a) Do not use any unpasteurized milk.
b) Only use pasteurized or long-life milk.
Do you have any questions that are not addressed in these instructions?
Please do not hesitate to contact your local customer service partner, Franke
Customer Service, or Franke Kaffeemaschinen AG in Aarburg.
NOTICE
Spoiled milk and ready-to-drink beverages
Insufficient cooling or hygiene can cause milk and ready-to-drink beverages to
spoil.
a) Only use pre-cooled milk and pre-cooled ready-to-drink beverages
(2.0−5.0 °C).
b) Only store milk and ready-to-drink beverages in the cooling unit when the
cooling unit is in operation. When the cooling unit is not in operation, e.g.
overnight, store milk and ready-to-drink beverages in a refrigerator.
c) Clean the machine and cooling unit once a day.
d) Only touch the suction hose, the inside of the container, and the con-
tainer lid after sanitizing your hands, or wear disposable gloves.
e) Place the container lid with the suction hose on a clean surface only.

Franke Kaffeemaschinen AG For your safety | 1
User manual UT40 CM and Pump Modules 9
NOTICE
Damage to the device
Connection lines could be damaged by tensile load.
Moisture entering the device can cause damage.
An unsuitable location can lead to damage.
a) Never pull on the connection lines.
b) Lay the connection lines in such a way that they do not form tripping haz-
ards.
c) Do not use jets of water or steam for cleaning.
d) Do not expose the device to the elements, such as rain, frost or direct
sunlight.
e) Place the device only on a level, stable surface.
NOTICE
Risk of damage to the compressor
If the ambient temperature is too low, the compressor oil may be too viscous,
resulting in the compressor being inadequately lubricated and being damaged
as a result.
a) Make sure that the permissible ambient temperature is maintained. De-
tails pertaining to climate classes can be found on the type plate and in
the technical data.

2 | Scope of delivery Franke Kaffeemaschinen AG
10 User manual UT40 CM and Pump Modules
2 SCOPE OF DELIVERY
Item description Item number
Manual set (UT40 CM) 560.0604.770
10 l container assembly (option)
– Container
– Lid
– Hose kit (CMB)
560.0586.023
560.0585.637
560.0603.666
This manual suits for next models
2