WARNING
Please read the manual carefully before you begin the installation and use. The installation of your new
garage door operator must be performed by a competent expert or a specialist company. A competent
person is, in accordance with EN 12635, considered a person who has appropriate training, qualified
knowledge and practical experience in order to mount a door system properly and safely, and maintain.
The installation or repair without technical qualifications can cause serious injury, death and / or property
damage.
25

CONTENTS
Important Safety Instructions...........……………………………....……………………………..27
Warranty Conditions.............................................................................................................30
Product Description & Features............................................................................................31
Pre-Installation Recommendations.......................................................................................32
Installation Instructions..........................................................................................................33
-Boom Rail Assembly
-Installation of Boom Rail and Operator
-Back-Up Battery installation (optional)
Programming Instructions....................................................................................................37
Connection of external control and accessories..................................................................40
Manual Disengagement.......................................................................................................42
Technical Specifications....………………………………………………………………….........43
Parts Listing……………………......…………….....................................................................45
Common Faults & Solutions.................................................................................................46
26

IMPORTANT SAFETY INSTRUCTIONS
1. Intended Use:
The garage door operator is designed exclusively for impulse operation of spring-balanced Sectional and
Up & Over garage doors doors in private / non-commercial operations. Door systems used in a public
area have only one protective device, e.g. the force limiter, and may only be operated under supervision.
The garage door operator is designed for operation in dry rooms.
2. Unintended Use:
The garage door operator must not be used for purposes other than for the automation of garage doors.
Continuous operation and the use in the commercial sector is not permitted. The operator must not be
used with doors without fall protection.
3. Qualification of the fitter and installer
Only correct fitting and maintenance by a competent / specialist company or a competent / qualified
person in accordance with the instructions can ensure the safe and flawless operation of the assembly. A
competent person is, in accordance with EN 12635, considered a person who has appropriate training,
qualified knowledge and practical experience in order to mount a door system properly and safely, and
maintain.
4. Safety instructions for installation, repair, maintenance and disassembly of the door system
DANGER!
Compensation springs are under high tension.
The adjusting or loosening the compensating springs can cause serious injuries! If necessary,
maintenance and repair work should only be performed by an expert! Never attempt to replace, readjust,
repair, or move the balancing spring for the counterbalancing of the door or their holders. Also inspect
that the entire door system (pivots, door bearings, ropes, springs and fastenings) for wear and possible
damage. Check them for signs of rust, corrosion and cracks. Error in the door system or misaligned
doors can cause severe injury! Do not use the door system if repair or adjustment work needs to be
done!
Mains Voltage
Dear Customer
Thank you for choosing a quality product from Force. Thanks to our unique quality
management system, we continuously ensure that Force operators meet the highest
standards of quality and comfort. Thank you for your confidence in purchase and we wish you
much pleasure with your new Force garage door opener.
Declaration of Conformity (CE)
The FS and PLUS series garage door openers from Force meet the requirements of the
applicable European and national guidelines. Compliance was demonstrated that
corresponding declarations, certificates, test reports and documents have been obtained by
the manufacturer and can be requested if required.
27

There is danger of electrocution upon contact with the mains voltage . Note, therefore, the following
instructions: Electrical connections may only be performed by a qualified electrician. Electrical installation
on site must comply with the relevant safety regulations (230/240 V AC, 50/60 Hz).
Disconnect the operator from the mains before performing any operator service
WARNING!
Non suitable fastening materials
Use of unsuitable fixing materials can result in the operator not being securely attached and can become
loosened. The supplied mounting materials must be checked for their suitability for the intended
installation location by the installer. Use the supplied mounting material (plugs) for concrete ≥ B15.
Fatal injury from hand rope
A guided type hand rope (pull cord) may lead to strangulation. Remove the pull rope/cord upon installing
the operator.
Risk of injury from unintentional door movement
An improper installation or handling of the operator can trigger unwanted door travel and can result in
people or objects being pinched. Follow all instructions contained in this manual. Any incorrectly mounted
control devices (such as push buttons) can unintentionally trigger door travel resulting in persons or
objects becoming pinched. Control devices must be mounted at a height of at least 1.5 m
(away from children). Assemble fixed control devices (such as push buttons) within sight of the door but
away from moving parts.
Risk of injury due to unexpected door travel
Installation, maintenance, repair and dismantling of the operator and the garage door must be carried out
by a specialist(s). Upon failure of the garage door operator, directly entrust an expert with the inspection
or repair.
Safety advice for mounting
The specialist must ensure that, in carrying out the installation, the applicable regulations regarding
occupational safety and those governing the operation of electrical equipment are complied with.
National guidelines must therefore be observed. Possible hazards, as defined in DIN EN 13241-1, are
prevented by the design and installation according to our specifications. The garage ceiling must be
designed so that a secure attachment of the opener system is ensured. Too high or too lightweight of
ceiling material, the opener system must be attached to additional safety/security braces.
CAUTION!
Crushing Risk by Boom Rail Mounting
When assembling the boom rail, there is a danger that fingers can be caught. Take care not to get your
fingers caught between the profile ends.
Pinching Risk in the Boom Rail
Grasping with fingers into the boom rail while the door is moving may cause pinching. Grasp only when
the door is not moving on the boom rail.
5.Safety information for commissioning and operation
CAUTION!
Pinching Risk in the Boom Rail
Grasping with fingers into the boom rail while the door is moving may cause pinching. Grasp only when
the door is not moving on the boom rail.
Risk of injury by pull cord
If you hang from the cord knob, the door can crash down and you can get hurt. The operator could
become dislodged and injure people underneath, damage or even destroy objects. Do not hang from the
pull cord.
28

WARNING!
Risk of injury by rapidly closing door
If the pull cord knob is pulled while the door is open, there is a risk that the door could close quickly
because of weak, broken or defective springs or due to faulty counterbalance mechanism. The pull cord
should only be pulled while the door is closed.
Risk of injury during door movement
While the door is moving, the risk of injury or damage to persons or objects is increased while standing
in the movement area of the door. Make sure that no children are playing with the door operator system.
Ensure that when the door is moving that no persons or objects are located within the door movement
area. Only use the garage door operator when you have view of the garage door it self and can monitor
its movement. Monitor the door travel until the door has reached the end position. Drive or pass through
the garage door entryway ONLY when the door has come to a standstill! Never stand directly under the
open door.
Proper Use
Demonstrate to all persons using the door operator system the proper and safe operation of the garage
door operator. Demonstrate and test the mechanical release as well as the safety return.
6. Precautions for the use of the remote control
WARNING!
Risk of injury from unwanted or accidental door movement
Accidental pressing of a button on the remote control can lead to unwanted door movements and injure
someone. Make sure that remote controls are not accessible to children and are only used by persons
who have been instructed in the operation of the remote-controlled garage door operator system! Only
use the remote when you are in visual contact with the door unless a safety device is connected ( e.g.
photocells). Drive or pass through the garage door entryway ONLY when the door has come to a
standstill! Never stand directly under the open door. Note that the accidentally pressing a key on the
remote (for example in your pocket / handbag) may lead to an unwanted door travel.
7. Safety Installations
Safety-related functions and components such as automatic power shutdown and the use of external
photocells have been tested and meet the requirements of EN 12453 and EN 12445 standards.
WARNING!
Risk of injury from malfunctioning safety devices
To test the safety reverse, with both hands, hold the door as it closes. The garage door operator system
must stop and initiate the safety reverse. Test this also as the garage door opens. The door system must
switch off and stop the door. Upon failure of the security reverse, directly entrust an expert with the
inspection or repair.
8. Inspection and maintenance
The garage door operator is maintenance-free. According to the manufacturer and for your own safety,
we recommend that you allow the garage door operator system to be inspected by an expert. A check or
a necessary repair should only be performed by a specialist. Please also contact your supplier. A visual
inspection may be carried out by the user. Check all safety and security features on a monthly basis.
Existing errors or defects must be rectified immediately. Inspect the tension of toothed belt every six
months and adjust accordingly if necessary. During the opening and closing phase, the belt may loll
briefly because of rail profile. However, this effect does not have any technical losses and also does not
adversely affect the function and life of the belt.
29

Warranty
We are exempt from the warranty and product liability if the unit has been modified without our prior
consent or improper installations are performed or initiated against our assembly instructions.
Furthermore, we assume no responsibility for the inadvertent or negligent operation of the operator, as
well as for the improper maintenance of the operator and accessories, nor for the improper maintenance
of the door and its counterbalance mechanism. Batteries, light bulbs, and LEDs are also excluded from
the warranty claims.
Duration of Warranty
In addition to the legal guarantee of the dealer from the purchase contract, we provide the following
warranty from date of purchase:
•3 Years
•2 Years on radio and accessories
The warranty time is not extended upon using the warranty. For replacement deliveries and rectification
work, the warranty period is six months or at least the remainder of the warranty period.
Conditions
The warranty applies only to the country where the product was purchased. The product must have been
purchased through our authorized distribution channels. The warranty only covers damage to the
contractual item itself. Reimbursement of expenditure for dismantling and installation, testing of
corresponding parts, as well as demands for lost profits and damages are excluded from the guarantee.
The receipt of purchase serves as proof of warranty.
Performance
For the duration of the warranty, we shall resolve any defects of the product which are demonstrably
attributable to a material or manufacturing defect. At our discretion, we shall, free of charge, replace the
defective product for a non-defective, repair or refund a diminished value. Excluded are damages
caused by:
•Improper installation and connection
•Improper commissioning and operation
•External influences such as fire, water, abnormal weather conditions
•Mechanical damage due to accidents, dropping or shock
•Negligent or deliberate destruction
•Normal wear and tear or poor maintenance
•Repair by unqualified persons
•Use of non-original parts
•Removal or obscuring of the serial number
•Replaced parts become property of the manufacturer
WARRANTY CONDITIONS
30

1. Automatic safety reverse
Automatic stop / automatic reverse are controlled by the software on our circuit boards. We are
cautious to protect your children, pets and property.
2. Soft start / Soft stop
Ramping speed up and down at the start and end of each cycle reduces stress on the door and
opener, and makes for longer life and quieter operation.
3. Auto-Close
Auto-Close ensures peace of mind and keeps your house secure by automatically closing the door upon
entering or exiting the garage.
4. Self learning - open and close obstruction force
The amount of opener power for different stages of the door’s travel is learned during setup and is
constantly re-profiled. Opener force measurement is automatically adjusted to a suitable range.
5. Simple adjustment of the end positions
Setting the end positions is easily done by pressing a button on the display panel.
6. Terminals for Accessories
Terminals are available for photocells (safety beam) extra receivers, wired or wireless wall
switches, caution/warning lights and more.
7. Energy saving LED
The courtesy LED light has a 3 minute delay, switching on with each cycle to illuminate your
darkened garage.
8. Battery backup available
Our openers can be connected with our battery backup in the event of power failure at your
home.
9. Self-Lock in gear motors
Force gear motors will self-lock with our disengagement systems.
10. Manual release
Don't worry about power failure, the manual release system is a solution for operation the door
at any time.
11. Transmitter technology
Rolling Code technology (7.38 x 1019 Combinations), 433.92Mhz frequency, 4 channel remote
control design ensures that you can control 4 different motors with one transmitter.
12. Lower headroom
With as little as 30mm required between the ceiling and the highest point of the door travel, the
opener can be flush mounted for low headroom applications.
13. Metal bottom plate, stronger and more secure
14. Open/Stop/Close - button (A)
Front panel open / stop / close buttons for operation. (see below)
15. External mains power fuse (B) (see below)
A
B
PRODUCT DESCRIPTION & FEATURES
31

PRE-INSTALLATION RECOMMENDATIONS
1. Check the garage door and garage door system
DANGER!
Balancing springs are under high tension. The readjustment or loosening of the balancing springs can
cause serious injuries! For your own safety, necessary maintenance and repair work should of the
balancing springs should only be performed by an expert.
Never attempt to replace, readjust, repair,or move the balancing springs for the counterbalancing of the
door or their holders. Check the entire door system (pivots, door bearings, ropes, springs and fastenings)
for wear and possible damage. Check them for signs of rust, corrosion and cracks. Error in the door
system or misaligned doors can cause severe injury! Do not use the door system if repair or adjustment
work needs to be done!
The construction of the operator is not designed to operate sluggish doors, i.e. doors that can no
longer or hardly be opened or closed manually. The door must be in a mechanically healthy state that is
easy to operate by hand (EN12604). Open the garage door approximately half way and let go.
The door should maintain this position and move neither up nor down. If the door moves in
either direction, then there is the risk that either the balancing springs/weights are not properly adjusted
or defective. In this case, increased wear and malfunctioning of the door is expected. Check that the
door can open and close correctly. Disengage/Remove any mechanical locks that may be on the
door -- they are not needed with the use of the garage door operator. These include in particular the
locking mechanisms connected with the door. For installation and commissioning, check the illustrated
section. Take note of the text in the appropriate sections.
2. Required Clearance
The clearance between the highest point of the door travel and the ceiling must be at least 30 mm. For a
lower clearance height, and if space is available, the operator can be mounted behind the opened door.
In these cases, an extended door link must be used and may be purchased separately. The necessary
electrical outlet for the electrical connection should be mounted within approx. 50 cm from the operator
(refer to the electrical mains chapter).
Check these dimensions!
Figure 1
32

INSTALLATION INSTRUCTIONS
Important note: As an additional safety device, the use of a photocell (safety beam) is recommended
(sold separately).
3. Emergency release
For garages without a second entrance, an emergency release for the mechanical release is necessary
to prevent getting locked in the garage in the event of power failure. The emergency release is door-
specific and must be ordered separately.
Check the function of the emergency release monthly.
Steel Boom Rail Assembly
3 Part Boom Rail
2 Part Boom Rail
A:1500 mm
B:1500 mm
Sleeve
C:1000 mm
Sleeve
Sleeve
D:1000 mm
E:1000 mm
Figure 2
Figure 3
1. 2-Part Rail
As in Figure 2, slide piece A into the sleeve, then slide piece B into the sleeve.
3-Part Rail
As in Figure 3, slide piece C into the first sleeve, followed by piece D. Then slide piece D and E
into the second sleeve
2. Cut the plastic thread; pull the screw rod along with inner belt to the end rail position (Figure 4).
3. Now run the spring and nut on the threaded rod as shown in Figure 5.
4. Tighten the nut to the proper position as shown in Figure 6. Remove the protective film and cut
the last cable ties on the sprocket -- the boom rail assembly is now complete.
33

Mount Wall Bracket and Door Bracket
Wall Bracket – Close the garage door and measure the garage door
width at the top and mark the center. Locate and mount the wall
bracket 2 cm - 15 cm above the door on the inside wall.
(Depending on the actual installation space).
Door Bracket – Attach the door bracket to a structural part of the
door as close to the top edge as possible.
Figure 7
F
F
Figure 4
Figure 5Figure 6
34
This manual suits for next models
1
Table of contents
Other Force Garage Door Opener manuals
Popular Garage Door Opener manuals by other brands

Craftsman
Craftsman 139.53924 owner's manual

Chamberlain
Chamberlain MyQ 940ESTD owner's manual

Automatic Technology
Automatic Technology GDO-9V1 SecuraLift installation instructions

Westfalia
Westfalia 19 36 07 instruction manual

Chamberlain
Chamberlain HD520EVP manual

Cardin
Cardin BL Series instruction manual