Fluke 9100S User manual

9100S
Dry-Well Calibrator
Users Guide
9100S___ugeng0000
1.888.475.5235info@Fluke-Direct.com Fluke-Direct.com

Limited Warranty & Limitation of Liability
Each product from Fluke Corporation, (“Fluke”) is warranted to be free from defects in material and
workmanship under normal use and service. The warranty period is one year for Dry-Well Calibrators. The
warranty period begins on the date of the shipment. Parts, product repairs, and services are warranted for 90
days. The warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller,
and does not apply to fuses, disposable batteries or to any other product, which in Fluke’s opinion, has been
misused, altered, neglected, or damaged by accident or abnormal conditions of operation or handling. Fluke
warrants that software will operate substantially in accordance with its functional specications for 90 days
and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be
error free or operate without interruption. Fluke does not warrant calibrations on the Field Metrology Well.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers
only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is
available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable
international price. Fluke reserves the right to invoice Buyer for importation costs of repairs/replacement
parts when product purchased in one country is submitted for repair in another country.
Fluke’s warranty obligation is limited, at Fluke’s option, to refund of the purchase price, free of charge
repair, or replacement of a defective product which is returned to a Fluke authorized service center within
the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with
a description of the difculty, postage, and insurance prepaid (FOB Destination), to the nearest Fluke
authorized service center. Fluke assumes no risk for damage in transit. Following warranty repair, the
product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that the
failure was caused by misuse, alteration, accident or abnormal condition or operation or handling, Fluke will
provide an estimate or repair costs and obtain authorization before commencing the work. Following repair,
the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair
and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF
ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL. OR
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING
FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER
THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion
or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may
not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court of
competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.
Specifications subject to change without notice. • Copyright © 2005 • Printed in USA
1.888.475.5235info@Fluke-Direct.com Fluke-Direct.com

i
Table of Contents
1 Before You Start .......................................................................1
1.1 Introduction ............................................................................................... 1
1.2 Symbols Used ........................................................................................... 1
1.3 Safety Information ..................................................................................... 3
1.3.1 Warnings .........................................................................................................3
1.3.2 Cautions ..........................................................................................................4
1.4 Authorized Service Centers ...................................................................... 5
2 Specications and Environmental Conditions ......................9
2.1 Specifications ........................................................................................... 9
2.2 Environmental Conditions ......................................................................... 9
3 Quick Start .............................................................................. 11
3.1 Unpacking .............................................................................................. 11
3.2 Set-up ..................................................................................................... 11
3.3 Power ...................................................................................................... 11
3.4 Setting the Temperature .......................................................................... 11
4 Parts and Controls ................................................................13
4.1 Rear Panel .............................................................................................. 13
4.2 Side View ................................................................................................ 14
4.3 Front Panel .............................................................................................. 15
4.4 Constant Temperature Block Assembly .................................................. 15
5 General Operation ..................................................................17
5.1 Setting the Temperature .......................................................................... 17
5.2 Changing Display Units .......................................................................... 17
6 Controller Operation ..............................................................19
6.1 Well Temperature .................................................................................... 19
6.2 Temperature Set-point ............................................................................ 19
6.2.1 Programmable Set-points .............................................................................19
6.2.2 Set-point Value ..............................................................................................20
6.2.3 Temperature Scale Units ...............................................................................20
6.3 Scan ........................................................................................................ 20
1.888.475.5235info@Fluke-Direct.com Fluke-Direct.com

9100S Dry-Well Calibrator
ii
6.3.1 Scan Control ..................................................................................................22
6.3.2 Scan Rate ......................................................................................................22
6.4 Set-point Resistance ............................................................................... 22
6.5 Secondary Menu..................................................................................... 23
6.6 Heater Power .......................................................................................... 23
6.7 Proportional Band ................................................................................... 23
6.8 Controller Configuration .......................................................................... 24
6.9 Operating Parameters ............................................................................ 25
6.10 High Limit ................................................................................................ 25
6.11 Serial Interface Parameters .................................................................... 25
6.11.1 Baud Rate .....................................................................................................25
6.11.2 Sample Period ...............................................................................................26
6.11.3 Duplex Mode .................................................................................................26
6.11.4 Linefeed ........................................................................................................27
6.12 Calibration Parameters ........................................................................... 27
6.12.1 Hard Cutout ...................................................................................................28
6.12.2 R0 ..................................................................................................................28
6.12.3 ALPHA ...........................................................................................................28
6.12.4 DELTA ............................................................................................................29
7 Digital Communication Interface ..........................................31
7.1 RS-232 Connection ................................................................................. 31
7.2 Interface Commands .............................................................................. 32
8 Test Probe Calibration ...........................................................35
8.1 Calibrating a Single Probe ...................................................................... 35
8.2 Dry-well Characteristics .......................................................................... 35
8.2.1 Stabilization and Accuracy ..........................................................................35
9 Calibration Procedure ............................................................37
9.1 Calibration Points .................................................................................... 37
9.2 Calibration Procedure ............................................................................. 37
9.2.1 Compute DELTA ............................................................................................38
9.2.2 Compute R0 and ALPHA ..............................................................................38
9.2.3 Accuracy and Repeatability ..........................................................................39
10 Maintenance ...........................................................................41
1.888.475.5235info@Fluke-Direct.com Fluke-Direct.com

iii
11 Troubleshooting .....................................................................43
11.1 Troubleshooting Problems, Possible Causes, and Solutions .................. 43
11.2 CE Comments ......................................................................................... 44
11.2.1 EMC Directive ...............................................................................................44
11.2.2 Low Voltage Directive (Safety) ......................................................................44
1.888.475.5235info@Fluke-Direct.com Fluke-Direct.com

9100S Dry-Well Calibrator
iv
Tables
Table 1International Electrical Symbols ............................................................ 1
Table 2Controller communications commands .............................................. 32
1.888.475.5235info@Fluke-Direct.com Fluke-Direct.com

v
Figures
Figure 1Back Panel ......................................................................................... 13
Figure 2Side view of the 9100S showing the prop stand ............................... 14
Figure 3Front panel ......................................................................................... 15
Figure 4Fixed block options ........................................................................... 16
Figure 5Controller operation flow chart .......................................................... 21
Figure 6Serial cable wiring ............................................................................. 31
1.888.475.5235info@Fluke-Direct.com Fluke-Direct.com

1.888.475.5235info@Fluke-Direct.com Fluke-Direct.com

1
Before You Start
Symbols Used
1 Before You Start
1.1 Introduction
The Fluke 9100S Mid-Range Field Calibrator may be used as a portable instrument or
bench top temperature calibrator for calibrating thermocouple and RTD temperature
probes. This instrument is small enough to use in the eld, and accurate enough to use
in the lab. Calibrations may be done over a range of 35°C to 375°C (95°F to 707°F).
Temperature display and setability resolution is 0.1 degrees.
The instrument features:
Rapid heating and cooling
Prop stand
RS-232 interface capability
Built in programmable features include:
Temperature scan rate control
Eight set-point memory
Adjustable readout in °C or °F
The temperature is accurately controlled by Fluke’s digital controller. The controller
uses a precision platinum RTD as a sensor and controls the well temperature with a
triac driven heater.
The LED front panel continuously shows the current well temperature. The
temperature may be set, using the control buttons, to any desired temperature within
the instrument’s range. Multiple fault protection devices insure user and instrument
safety and protection.
This dry-well calibrator was designed for portability, low cost, and ease of operation.
Through proper use, the instrument will provide continuous accurate calibration
of temperature sensors and devices. The user should be familiar with the safety
guidelines and operating procedures of the calibrator as described in the instruction
manual.
1.2 Symbols Used
Table 1 lists the International Electrical Symbols. Some or all of these symbols may be
used on the instrument or in this manual.
Table 1 International Electrical Symbols
Symbol Description
AC (Alternating Current)
1.888.475.5235info@Fluke-Direct.com Fluke-Direct.com

9100S Dry-Well Calibrator
Symbols Used
2
Symbol Description
AC-DC
Battery
Complies with European Union directives
DC
Double Insulated
Electric Shock
Fuse
PE Ground
Hot Surface (Burn Hazard)
Read the User’s Guide (Important Information)
Off
On
Canadian Standards Association
CAT II OVERVOLTAGE (Installation) CATEGORY II, Ploution Degree 2 per IEC1010-1
refers to the level of Impulsive Withstand Voltage protection provided. Equipment of
OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from the
xed installation. Examples include household, office, and laboratory appliances.
C-TICK Australian EMC mark
The European Waste Electrical and Electronic Equipment (WEEE) Directive (2002/96/
EC) mark.
1.888.475.5235info@Fluke-Direct.com Fluke-Direct.com
Other manuals for 9100S
1
Table of contents
Other Fluke Test Equipment manuals

Fluke
Fluke 1587 User manual

Fluke
Fluke TL1000-KIT Original instructions

Fluke
Fluke AIRCHECK User manual

Fluke
Fluke ScopeMeter 190-104 User manual

Fluke
Fluke 719PRO User manual

Fluke
Fluke 1652C Use and care manual

Fluke
Fluke 718-100G User manual

Fluke
Fluke CableAnalyzer DTX-1500 Use and care manual

Fluke
Fluke 725Ex User manual

Fluke
Fluke T3 Use and care manual

Fluke
Fluke 7080 User manual

Fluke
Fluke 5520A Service Manual

Fluke
Fluke 700PTP User manual

Fluke
Fluke HART 744 User manual

Fluke
Fluke 105B User manual

Fluke
Fluke Versiv User manual

Fluke
Fluke Series II User manual

Fluke
Fluke 1662 User manual

Fluke
Fluke 7526A-156 Use and care manual

Fluke
Fluke 5520A Service User manual