Fluke SimpliFiber 850 User manual

SimpliFiber Source English Instruction Sheet
10/23/02
Dimensions: 4.75” x 8.25”
Page
1
PN 2031600 September 2002
© 2002 Fluke Networks, Inc. All rights reserved. Printed in USA.
All product names are trademarks of their respective companies.
SimpliFiber
Optical Power Source
Instruction Sheet
The SimpliFiber optical power source provides optical power for testing
fiber opticcables.Youcanusethesource withanyloss test set.
This instruction sheet covers the following models:
•The SimpliFiber 850/1300 Source, which provides 850 nm and
1300 nm optical power for testing multimode fiber.
•The SimpliFiber 1310 Source, which provides 1310 nm optical
power for testing singlemode fiber.
•The SimpliFiber 1550 Source, which provides 1550 nm optical
power for testing singlemode fiber.
A SimpliFiber source comes with the following:
•Holster with connector cover
•Dust cap(s)
•2 AA batteries (installed)
•Instruction sheet
•Warranty registration card
Registration
Registering your product with Fluke Networks gives you access to
valuable information on product updates, troubleshooting tips, and
other support services. To register, fill out and return the postage-paid
card provided, or fill out the online registration
Networkswebsiteatwww.flukenetworks.com/registration.
form on the Fluke

Simplifiber English Instruction Sheet
10/23/02
Dimensions: 4.75” x 8.25”
Page
2
Contacting Fluke Networks
VisittheFluke Networkswebsiteatwww.flukenetworks.com. Send
email to support@flukenetworks.com.
For operating assistance in the USA, call 1-800-283-5853.
To order accessories or get the location of the nearest Fluke Networks
distributor or service center, call:
•USA: 1-888-99-FLUKE (1-888-993-5853)
•Canada: 1-800-363-5853
•Europe: 00800 632 632 00 or +44 1923 281 300
•Beijing: 86 (10) 6512-3435
•Japan: +81-3-3434-0181
•Singapore: +65-6738-5655
•Anywhere in the world: +1-425-446-4519
Visit our website for the latest list of phone numbers.
Precautions and Safety Information
•Always clean the fiber optic connectors before use.
•Before testing, let the source stabilize for 5 minutes after you turn
it on.
W*Warning: Class 1 Laser Product
To avoid possible eye damage caused by hazardous radiation:
•Never look directly into optical output connectors. Some
sources produce invisible radiation that can permanently
damage your eyes.
•Do not open the case, except to change the batteries. No
user-serviceable parts are inside.
•Do not modify the source.
•Do not magnify or otherwise modify the source output.
Use only approved connectors and adapters.
•Do not use controls, adjustments, or procedures not
documented or approved by Fluke Networks.

Simplifiber English Instruction Sheet
10/23/02
Dimensions: 4.75” x 8.25”
Page
3
850/1300 Source Features
B
F
A
C
D
G
H
E
alq01.eps
Warning
Read “Precautions and Safety Information” before using the source.
A850 nm port with SC or ST connector. The LED lights when the
port is active.
B1300 nm port with SC or ST connector. The LED lights when the
port is active.
CThe LED lights when the output is in continuous wave (CW) mode
or blinks when the output is modulated at 2 kHz. Press Cto
switch modes. Use continuous wave mode (LED on steady) for
making loss or power measurements with a meter other than a
SimpliFiber meter. Use the 2 kHz modulated mode for identifying
fibers with a fiber identifier.
DLow battery LED. Replace the batteries when the LED lights.
ESwitches the output between 850 nm and 1300 nm.
FSwitches the output between continuous wave (CW) and 2 kHz
modulated modes. See C.
GOn/off key.
HSwitches the output to Auto mode, which is used only with the
SimpliFiber meter. In Auto mode the output is encoded to tell the
SimpliFiber meter which wavelength is being transmitted. Press
Cto exit Auto mode.
See the documentation for your fiber optic meter for details on
setting a reference and making measurements.

Simplifiber English Instruction Sheet
10/23/02
Dimensions: 4.75” x 8.25”
Page
4
1310 and 1550 Source Features
A
D
B
C
E
F
alq02.eps
W* Warning: Class 1 Laser Product
Read “Precautions and Safety Information” before using the source.
A1310 nm or 1550 nm port with SC or ST connector. The LED lights
when the port is active.
BThe LED lights when the output is in continuous wave (CW) mode
or blinks when the output is modulated at 2 kHz. Press Cto
switch modes. Use continuous wave mode (LED on steady) for
loss or power measurements when using a meter other than the
SimpliFiber meter. Use the 2 kHz modulated mode for identifying
fiber cables with a fiber identifier.
CLow battery LED. Replace the batteries when the LED lights.
DSwitches the output between continuous wave (CW) and 2 kHz
modulated modes. See C.
EOn/off key.
FSwitches the output to Auto mode, which is used only with the
SimpliFiber meter. In Auto mode the output is encoded to tell the
SimpliFiber meter which wavelength is being transmitted. Press
Cto exit Auto mode.
See the documentation for your fiber optic meter for details on
setting a reference and making measurements.

Simplifiber English Instruction Sheet
10/23/02
Dimensions: 4.75” x 8.25”
Page
5
Maintenance
Clean the case with a soft cloth and mild detergent. Do not use
abrasives or solvents.
Clean the connectors with lint-free swabs, wipes moistened with
isopropyl alcohol, or pre-moistened swabs or wipes approved for use on
fiber connectors. Always dry the connectors immediately after cleaning.
Periodically inspect the connector endfaces with a fiber microscope,
such as a Fluke Networks FiberInspectorVideo Microscope. If an
endface is damaged, contact Fluke Networks for service information.
Replace the batteries when the Low Battery LED lights. The source uses
2 AA alkaline batteries. To access the batteries, remove the battery
compartment cover on the back of the source.
Replacement Parts
The following replacement parts for the SimpliFiber source are
available from Fluke Networks. Visit the Fluke Networks website for a
complete list of fiber test accessories.
Description Fluke Networks
Part Number
Yellow holster with connector cover 1705523
Battery door 1704450
Instruction sheet 2031600
Specifications
Emitter type 850/1300 source: infrared LED
1310 and 1550 sources: laser
Laser classification for 1310 and
1550 sources
Class 1
Safety for 1310 and 1550 sources Complies with ANSI/ISA S82.01-
1994, CSA C22.2 No. 1010.1-92,
EN61010.1:1993
Output power 850/1300 source: >-20 dBm
1310 source: >-10 dBm
1550 source: >-10 dBm
Power output stability (8 hours) ±0.25 dB at 73 °F (23 °C)

Simplifiber English Instruction Sheet
10/23/02
Dimensions: 4.75” x 8.25”
Page
6
Specifications (cont.)
Connector SC or ST, depending on model
Battery type and life Two AA alkaline batteries
(NEDA 15A or IEC LR6)
850/1300 source: 10 to 50 hours,
depending on mode
1310 and 1550 sources: 20 to 100 hours,
depending on mode
Temperature range Operating: 32 °F to 113 °F (0 °C to 45 °C)
Storage: -4 °F to +120 °F (-20 °C to +60 °C)
Humidity Operating: 10 % to 90 % non-condensing
Storage: 5 % to 95 % non-condensing
Certifications
Dimensions (in holster) 6.25 in x 3.50 in x 1.13 in
(15.88 cm x 8.89 cm x 2.87 cm)
Weight (in holster) 200 g (7 oz)
LIMITED WARRANTY & LIMITATION OF LIABILITY
Fluke Networks products will be free from defects in material and workmanship for
one year from the date of purchase. Parts, accessories, product repairs, and services
are warranted for 90 days. This warranty does not cover disposable batteries, cable
connector tabs, cable insulation-displacement connectors, or damage from accident,
neglect, misuse, alteration, contamination, or abnormal conditions of operation or
handling. Resellers are not authorized to extend any other warranty on Fluke
Networks’ behalf. To obtain service during the warranty period, contact your nearest
Fluke Networks authorized service center to obtain return authorization information,
then send your defective product to that Service Center with a description of the
problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS
FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE
NETWORKS IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY.
Since some states or countries do not allow the exclusion or limitation of an implied
warranty or of incidental or consequential damages, this limitation of liability may not
apply to you.
6/01
Fluke Networks, Inc.
PO Box 777
Everett, WA 98206-0777
USA
This manual suits for next models
1
Table of contents
Other Fluke Portable Generator manuals

Fluke
Fluke 291 Parts list manual

Fluke
Fluke PM5418 User manual

Fluke
Fluke DDS Function Generator 271 Parts list manual

Fluke
Fluke 281 Parts list manual

Fluke
Fluke 6080A User manual

Fluke
Fluke 6070A User manual

Fluke
Fluke 281 User manual

Fluke
Fluke PM5414V User manual

Fluke
Fluke 291 User manual

Fluke
Fluke Wavetek-Datron 395 Instruction Manual