FLIR F-Series User manual

427-0033-00-12 Version 110 February 2019
This document does not contain any export-controlled information.
Installation
Manual
F-Series ID

427-0033-00-12 Version 110
This document does not contain any export-controlled information.
© 2019 FLIR Systems, Inc. All rights reserved worldwide. No parts of this manual, in whole or in part, may be
copied, photocopied, translated, or transmitted to any electronic medium or machine readable form without the
prior written permission of FLIR Systems, Inc.
Names and marks appearing on the products herein are either registered trademarks or trademarks of FLIR
Systems, Inc. and/or its subsidiaries. All other trademarks, trade names, or company names referenced herein are
used for identification only and are the property of their respective owners.
This product is protected by patents, design patents, patents pending, or design patents pending.
Photographs and images appearing in this manual may have been modified for illustrative purposes using
commercial image editing software and may not always reflect an actual product configuration.
The contents of this document are subject to change without notice.
For additional information visit www.flir.com or write to FLIR Systems, Inc.
FLIR Systems, Inc.
6769 Hollister Avenue
Goleta, CA 93117
Support: https://www.flir.com/support-center/support-hq/
Important Instructions and Notices to the User:
Modification of this device without the express authorization of FLIR Systems, Inc., may void the user’s authority
under the FCC Rules to operate this device.
Note 1: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense. Shielded cables
must be used to connect this device to other devices.
Note 2: If ferrites are supplied with this equipment, the equipment was tested for compliance with the FCC limits for
a Class A digital device using power cables with the ferrites installed. When connecting one or two power cables to
the equipment, the supplied ferrites must be used with this equipment.
Industry Canada Notice:
This Class A digital apparatus complies with Canadian ICES-003.
Avis d’Industrie Canada:
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Proper Disposal of Electrical and Electronic Equipment (EEE)
The European Union (EU) has enacted Waste Electrical and Electronic Equipment
Directive 2002/96/EC (WEEE), which aims to prevent EEE waste from arising; to encourage
reuse, recycling, and recovery of EEE waste; and to promote environmental responsibility.
In accordance with these regulations, all EEE products labeled with the crossed out
wheeled bin either on the product itself or in the product literature must not be disposed of in
regular rubbish bins, mixed with regular household or other commercial waste, or by other
regular municipal waste collection means. Instead, and in order to prevent possible harm to
the environment or human health, all EEE products (including any cables that came with the
product) should be responsibly discarded or recycled.
To identify a responsible disposal method nearby, please contact a local waste collection or recycling service, the
original place of purchase or product supplier, or the responsible government authority in the area. Business users
should contact their supplier or refer to their purchase contract.
Document History
Version Date Comment
100 December 2018 V1.3.0
110 February 2019 Updated video encoding defaults and firmware update information; added 802.1x
support, TLS configuration, and Nexus CGI interface

Table of Contents
427-0033-00-12 Version 110 February 2019 3
This document does not contain any export-controlled information.
Table of Contents
F-Series ID Camera Installation
1.1 Camera Overview ...................................................................................................... 5
1.2 Warnings and Cautions .............................................................................................. 5
1.3 Installation Overview .................................................................................................. 6
1.3.1 Camera Connection Options ............................................................................. 6
1.3.2 Camera Mounting Accessories ......................................................................... 7
1.3.3 Supplied Components ....................................................................................... 7
1.3.4 Additional Supplies ........................................................................................... 7
1.3.5 Camera Placement ........................................................................................... 8
1.3.6 Bench Testing ................................................................................................... 8
1.3.7 Prior to Cutting/Drilling Holes ............................................................................ 8
1.3.8 Camera Mounting ............................................................................................. 8
1.3.9 Removing the Back Cover ................................................................................ 9
1.3.10 Cable Gland Sealing ....................................................................................... 9
1.3.11 Cable Glands and Spare Parts Kit ................................................................ 10
1.3.12 Cable Gland Seal Inserts .............................................................................. 10
1.4 Camera Connections ............................................................................................... 11
1.4.1 Connecting power ........................................................................................... 11
1.4.2 Video Connection ............................................................................................ 12
1.4.3 GPIO Alarm Connections ................................................................................ 12
1.4.4 Ethernet Connection ....................................................................................... 12
1.5 F-Series ID Camera Specifications .......................................................................... 13
Basic Operation and Configuration
2.1 IP Camera, ONVIF Profile S Compliant ................................................................... 15
2.1.1 Server Configuration ....................................................................................... 15
2.2 Camera Bench Test ................................................................................................. 15
2.2.1 Set IP Address using the FLIR Discovery Network Assistant (DNA) .............. 15
2.2.2 Log into the Camera Web Page ...................................................................... 16
2.2.3 Live Video Page .............................................................................................. 17
2.3 Basic Camera Configuration .................................................................................... 20
2.3.1 Expert and Admin Accounts ............................................................................ 20
2.3.2 Setup Menu ..................................................................................................... 20
2.3.3 Maintenance Menu > Server Page ................................................................. 21
2.4 Thermal Imaging Overview ...................................................................................... 29
2.5 Troubleshooting Tips ............................................................................................... 30

Table of Contents
427-0033-00-12 Version 110 February 2019 4
This document does not contain any export-controlled information.
Advanced Configuration
3.1 Setup Menu ..............................................................................................................33
3.1.1 Temperature Page ...........................................................................................33
3.1.2 Input/Output (IO) Page ....................................................................................34
3.1.3 Video Setup .....................................................................................................34
3.1.4 Thermal Image Setup - IR Page ......................................................................36
3.1.5 Video Analytics Setup ......................................................................................38
3.2 Maintenance Menu ...................................................................................................43
3.2.1 Sensor Menu ...................................................................................................44
3.2.2 Files Menu .......................................................................................................57
3.2.3 Product Info Menu ...........................................................................................60

1
427-0033-00-12 Version 110 February 2019 5
This document does not contain any export-controlled information.
F-Series ID Camera Installation
This manual describes the installation and initial configuration of the F-Series ID thermal camera. The
F-Series ID camera has software providing for on-board video analytics: setting of detection regions,
trip lines, and classification of detected objects. Refer to Video Analytics Setup, pg. 38.
1.1 Camera Overview
The F-Series ID cameras are components within the FLIR Thermal Fence. The video from the camera
can be viewed over a traditional analog video network or it can be viewed by streaming it over an IP
network using M-JPEG and H.264 encoding. The Ethernet connection also provides for camera
configuration and control using either a web browser or a video management system (VMS) such as
FLIR LatitudeTM.
The FLIR Thermal Fence combines FLIR thermal security cameras and the FLIR Latitude control and
management software in a fully integrated perimeter security solution. The FLIR Thermal Fence
provides automated perimeter surveillance, intrusion detection, and alert capabilities for perimeter
security applications including critical infrastructure, petrochemical facilities, nuclear facilities,
commercial campuses, and residential neighborhoods. The FLIR Thermal Fence gives you instant,
automated threat detection and visual threat assessment capability around the clock in one easy-to-
use package.
If help is needed during the installation process, contact the local FLIR service representative or
contact support at: https://www.flir.com/support-center/support-hq/. All installers and integrators are
encouraged to take advantage of the training offered by FLIR; visit
https://www.flir.com/support-center/training/ for more information.
1.2 Warnings and Cautions
For safety, and to achieve the highest levels of performance from the F-Series ID camera system,
always follow the warnings and cautions in this manual when handling and operating the camera.
Warning!
Caution!
If mounting the F-Series ID camera on a pole, tower or any elevated location, use industry standard
safe practices to avoid injuries.
Except as described in this manual, do not open the F-Series ID camera for any reason.
Disassembly of the camera can cause permanent damage and will void the warranty.
Be careful not to leave fingerprints on the F-Series ID camera’s infrared optics.
The F-Series ID camera requires a power supply of 24 V. Operating the camera outside the specified
input voltage range or the specified operating temperature range can cause permanent damage.

427-0033-00-12 Version 110 February 2019 6
This document does not contain any export-controlled information.
F-Series ID Camera Installation
1.3 Installation Overview
The F-Series ID Camera is an infrared thermal imaging camera intended for outdoor applications,
and can be installed in a fixed location or on a pan/tilt mechanism.
The F-Series ID camera is intended to be mounted on a medium-duty fixed pedestal mount or wall
mount commonly used in the CCTV industry. Cables exit from the back of the camera housing. The
mount must support up to 30 lbs. (15 KG).
1.3.1 Camera Connection Options
Camera connections are made through water-tight cable gland seals on the rear of the camera.
Refer to Cable Gland Sealing, pg. 9 to ensure the glands are used correctly and the connections are
properly sealed.
The camera is powered with a conventional power supply using 21 - 30 Vac or 21 - 30 Vdc.
The F-Series ID camera produces both analog video and digital (IP) video output. Analog video will
require a connection to a video monitor or an analog video matrix switch.
An Ethernet connection is required for IP video streaming and for command and control
communications.
Several third-party video management systems are supported by FLIR IP cameras. Because these
systems tend to evolve and change over time, contact the local FLIR representative or FLIR
Technical Support for information.
General Purpose Input/Output (GPIO)
The camera can receive a single input signal and can provide a single output signal. Refer to GPIO
Alarm Connections, pg. 12.
Input Signal—When an external alarm device closes a switch to complete the circuit for the
camera, an input alarm is generated by the GPIO for the Alarm Manager.
Output Signal—When an output alarm is generated by the Alarm Manager for the GPIO, the
camera closes its internal switch to complete the circuit for the receiving device.
Figure 1-1: F-Series ID Camera
Shipping plugs only -
Remove before installing

427-0033-00-12 Version 110 February 2019 7
This document does not contain any export-controlled information.
F-Series ID Camera Installation
1.3.2 Camera Mounting Accessories
The following accessories are available for purchase from FLIR Systems, Inc.
• Wall Mount Kit (500-0462-00) – The wall mount is designed to safely support loads up to 40
pounds (18 kg). The mount features a fully adjustable swivel head allowing 360 degree
horizontal and 75 degree vertical adjustment. The mount is constructed of aluminum with a gray
polyester powder coat finish.
• Pole Mount Adapter (4119507) – The pole mount adapter is designed for use with the wall
mount kit (500-0462-00) when installation is required on a pole. The adapter attaches on poles
having 1.5-inch (3.81 cm) to 8-inch (20.32 cm) diameters. The mount is constructed of aluminum
with a gray polyester powder coat finish and stainless steel straps.
• Pedestal Mount Kit (500-0463-00) – The pedestal mount is designed to support loads up to 40
pounds (18 kg). The mount features a fully adjustable swivel head allowing 360 degree
horizontal and 75 degree vertical adjustment. The mount is constructed of aluminum and has a
gray polyester powder coat finish.
1.3.3 Supplied Components
The F-Series ID camera includes these standard components:
• Fixed Camera Unit
• Cable Glands and Spare Parts kit
1.3.4 Additional Supplies
The installer will need to supply the following items, which are specific to the installation.
Refer to Camera Connections, pg. 11.
• 24 V Power supply
• Electrical wire: system power, 3-conductor, shielded, gauge determined by cable length;
GPIO alarm cable (optional), 5-conductor, 20 AWG maximum
• Camera grounding strap
• Coaxial RG59U video cables (BNC connector at the camera end) for analog video (optional)
• Shielded Category 6 Ethernet cable for control, streaming video, and for software updates.
• Hardware/software for viewing the video (streaming IP video or analog video)
• Miscellaneous electrical hardware, camera mount, connectors, and tools

427-0033-00-12 Version 110 February 2019 8
This document does not contain any export-controlled information.
F-Series ID Camera Installation
1.3.5 Camera Placement
The F-Series ID camera should be mounted upright on top of the mounting surface. Adhere to all
local and industry standards, codes, and best practices.
For installations with multiple cameras with on-board video analytics, the fields of view of cameras
should overlap in order to remove all dead zones in which a camera cannot see a target “head to
toe”. The camera’s on-board analytics must be calibrated to detect targets. Refer to Video Analytics
Setup, pg. 38.
• Install the camera at a height of approximately 4 m (13 ft) or more.
• Typically direct the camera towards the ground with the maximum possible tilt angle (α) to
ensure that the field of view includes as little of the skyline as possible.
• Ensure that cameras are mounted on stable mounts with minimal vibrations and maximal
resistance to wind.
• The tilt angle (α) is the angle between vertical and the center of the camera field of view.
1.3.6 Bench Testing
Connect the power, analog video, and Ethernet connections and confirm that the video is shown on
a monitor when the power is turned on. The IP address of the camera web server is shown on the
analog video for approximately 90 seconds after power is applied. For configuration and basic setup
information using the onboard web server, refer to Camera Bench Test, pg. 15.
1.3.7 Prior to Cutting/Drilling Holes
When selecting a mounting location for the F-Series ID camera, consider cable lengths and cable
routing. Ensure the cables are long enough, given the proposed mounting locations and cable
routing requirements, and route the cables before you install the components.
Use cables that have sufficient dimensions to ensure safety (for power cables) and adequate signal
strength (for video and communications).
1.3.8 Camera Mounting
F-Series ID cameras must be mounted upright on top of the mounting surface, with the base below
the camera. The unit should not be hung upside down.
Verify both sides of the mounting surface are accessible.
α

427-0033-00-12 Version 110 February 2019 9
This document does not contain any export-controlled information.
F-Series ID Camera Installation
Use a thread locking compound such as Loctite 242 or equivalent with all metal to metal threaded
connections.
Once the holes are drilled in the mounting surface, install three (3) to five (5) 1/4-20 threaded
fasteners into the base of the camera with thread-locking compound.
Secure the camera to the mount with three (3) to five (5) 1/4-20 threaded fasteners as shown below.
1.3.9 Removing the Back Cover
Use a 3 mm hex key to loosen the four captive screws,
exposing the connections at the back of the camera
enclosure. There is a grounding wire connected
between the case and the back cover as shown. If the
grounding wire is temporarily disconnected during the
installation, it must be reconnected to ensure proper
grounding of the camera.
1.3.10 Cable Gland Sealing
Proper installation of cable sealing glands and use of
appropriate elastomer inserts is critical to long term
reliability. Cables enter the camera mount enclosure
through liquid-tight compression glands. Leave the
gland nuts loosened until all cable installation has been
completed. Inspect and install gland fittings in the back cover with leak sealant and tighten to ensure
water tight fittings. Teflon tape or pipe sealant (i.e. DuPont RectorSeal T™) are suitable sealants.
Figure 1-2: F-Series ID Camera Mounting Holes
5.0
(NOMINAL
BASE SURFACE
DIAMETER)
F.O.V.
DIRECTION
±.0201.00
1.00±.020
1.00±.020
1.00±.020
5X 1/4 - 20 THREAD, 0.75 DEEP
Not to scale
All dimension are in inches

427-0033-00-12 Version 110 February 2019 10
This document does not contain any export-controlled information.
F-Series ID Camera Installation
1.3.11 Cable Glands and Spare Parts Kit
The kit contains the two 3/4” cable glands and gland
seal plugs required for non-conduit installations.
The remaining parts included in the kit are:
• a spare ground wire
• a spare ground nut and lock washer
• two spare power terminal block plugs
• two spare terminal block plugs
• four spare F-Series back cover screws
1.3.12 Cable Gland Seal Inserts
The camera comes with two 3/4” NPT cable
glands, each with a three hole gland seal
insert. Cables may be between 0.23" to 0.29"
OD. Up to five cables may be needed. Plugs
are required for any insert hole(s) not used.
If non-standard cable diameters are used, you
may need to locate or fabricate the
appropriate insert to fit the desired cable. FLIR
Systems, Inc. does not provide cable gland
inserts other than the inserts supplied with the
system.
Note
Insert the cables through the gland seal before terminating and connecting them. The terminated
connectors will generally not fit through the cable gland. If a terminated cable is required, make a
clean, singular cut in the gland seal to install the cable into the gland seal.
Camera Power
GPIO Alarm Ethernet
Heater Power
Seal plugs
Ground
Lug
Other manuals for F-Series
3
This manual suits for next models
2
Table of contents
Other FLIR Thermal Camera manuals

FLIR
FLIR SCION User manual

FLIR
FLIR E54-24 User manual

FLIR
FLIR Voyager II Installation and operating instructions

FLIR
FLIR HM-Series User manual

FLIR
FLIR T43 User manual

FLIR
FLIR ThermoVision PathFindIR LE User manual

FLIR
FLIR Vue User manual

FLIR
FLIR A310 ex Series User manual

FLIR
FLIR ThermaCAM BX320 User manual

FLIR
FLIR FLIR E95 User manual