Fivemere SBU14C User manual

SBU Systems
User Manual
Fivemere Ltd.
Unit 1, Heron Industrial Estate
Basingstoke Road
Spencers Wood
Reading, Berks, RG7 1PJ
United Kingdom
Telephone: [44] (0) 118 988 0082
Fax: [44] (0) 118 988 0081

SBU SystemsUser Manual
80-30200000-03ii
Publication — 80-30200000-03
Publication Notice:
This manual has been compiled and checked for accuracy. However the
information contained in this manual does not constitute a warranty of
performance. Fivemere Limited reserves the right to revise this
publication from time to time without notice. Fivemere Limited assumes
no liability for losses incurred as a result of out-of-date or incorrect
information contained in this manual.
Proprietary Notice:
©1996-1999, Fivemere Ltd, all rights reserved.
This document may not in whole or part be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-
readable form without prior consent from Fivemere Limited.
EMC Directive:
This product has been designed for use in Commercial and Light
Industrial environments and tested to relevant EMC Standards as listed
in the European O.J. All testing was carried out using screened
interconnection cables. Should the equipment be used in a different
environment the user may need to take additional EMC precautions.
Fivemere Ltd. is a subsidiary of Cabletron Systems Inc., USA.

SBU SystemsUser Manual
80-30200000-03 iii
History Sheet
80-30200000-01 First Edition March 1996
80-30200000-02 Cabletron Systems Ltd 29 April 1997
80-30200000-03 Fivemere Ltd version,
SBULSM section added 19 October 1999

SBU SystemsUser Manual
80-30200000-03iv
TABLE OF CONTENTS
1. SCOPE AND INTRODUCTION 1-1
1.1 SCOPE 1-1
1.2 INTRODUCTION 1-1
1.3 THE SBU14C 1-2
1.4 THE SBU6C 1-3
2. INSTALLATION AND CABLING 2-1
2.1 MAINS INPUT AND WIRING 2-1
2.2 SUPPLY RATINGS AND FUSING 2-3
2.2.1 SBU14C 2-3
2.2.2 SBU6C 2-4
2.3 POWER SUPPLY CAPACITIES/REDUNDANCY 2-5
2.3.1 SBU14C 2-5
2.3.2 SBU6C 2-6
3. OVERVIEW OF SHELF MODULES 3-1
3.1 POWER SUPPLIES 3-1
3.1.1 SBU14C 3-1
3.1.2 SBU6C 3-1
3.2 COOLING 3-2
3.2.1 SBU14C 3-2
3.2.2 SBU6C 3-2
3.3 GENERIC SHELF MANAGER MODULE (SBUGSM) 3-2
3.4 LAN SHELF MANAGER MODULE (SBULSM) 3-2
3.5 GENERIC PORT SHARER MODULE (SBUGPS) 3-2
4. GENERIC SHELF MANAGER MODULE 4-1
4.1 OVERVIEW 4-1
4.2 SHELF POWER LOADING 4-2
4.3 COMMAND ACCESS TO THE SBUGSM 4-3
4.3.1 POLL ADDRESSES AND ALERT FORMAT 4-3
4.3.2 FACTORY DEFAULT 4-5
4.3.3 PASSWORD ENTRY 4-5
4.4 INTERFACES 4-5
4.5 OPERATION MENU (A) 4-6
4.6 CONFIGURATION MENU (B) 4-6
4.6.1 SYSTEM MENU 4-6

SBU SystemsUser Manual
80-30200000-03 v
4.6.2 COMMAND PORT MENU 4-7
4.6.3 ALARM PORT MENU 4-8
4.6.4 ALARMS MENU 4-9
4.7 LOGOUT (C) 4-9
5. LAN SHELF MANAGER MODULE 5-1
5.1OVERVIEW 5-1
5.2 SHELF POWER LOADING 5-3
5.3 COMMAND ACCESS TO THE SBULSM 5-3
5.3.1 POLL ADDRESSES AND ALERT FORMAT 5-3
5.3.2 IP ADDRESS 5-5
5.3.3 FACTORY DEFAULT 5-5
5.3.4 PASSWORD ENTRY 5-5
5.4 INTERFACES 5-5
5.5 OPERATION MENU (A) 5-6
5.6 CONFIGURATION MENU (B) 5-6
5.6.1 SYSTEM MENU 5-7
5.6.2 COMMAND PORT MENU 5-7
5.6.3 ALARM PORT MENU 5-9
5.6.4 ALARMS MENU 5-10
5.6.5 REMOTE PORT MENU 5-11
5.6.6 NUMBER STORE MENU 5-11
5.6.7 LAN MENU 5-11
5.7 LOGOUT (C) 5-14
6. GENERIC PORT SHARER 6-1
6.1 PHYSICAL REQUIREMENTS 6-1
6.2 PANEL LAYOUTS 6-1
6.3 SHELF POWER LOADING 6-3
6.4 FUNCTIONAL DESCRIPTION 6-3
6.5 PHYSICAL INTERFACE 6-3
6.6 CARD JUMPERS 6-4
7. SHELF SPECIFICATIONS 7-1
7.1 SBU14C 7-1
7.2 SBU6C 7-2
8. CABLING DIAGRAMS 8-1
8.1 PC 9 WAY TO SBUGSM/SBULSM 8-1
8.2PC 25 WAY TO SBUGSM/SBULSM 8-2

SBU SystemsUser Manual
80-30200000-03vi
8.3 PC 25 WAY TO SBUGPS MASTER PORT 8-2
8.4 SBUGPS CHANNEL TO SBUGSM/SBULSM 8-3
8.5PC 9 WAY TO SBUGPS MASTER 8-3
9. GLOSSARY OF TERMS 9-1

Scope and Introduction
80-30200000-03 1-1
1. Scope and Introduction
1.1 Scope
This manual provides user information for both the Fivemere SBU14C
and the SBU6C. Although there is indeed no actual ‘operation’ of these
shelves, it is necessary to understand their functionality both from the
point of view of the services they provide as a host to shelf-mounted
products.
These products were previously known as CBU/14 and CBU/6.
1.2 Introduction
Both shelves allow for dense concentration of Fivemere communications
products together with centralised management, alarm reporting, and
resilient Power Supplies. They are designed to accept present and
future Fivemere Shelf mounting products. These products are designed
to be on line compatible with the earlier Fivemere ISDN products.

SBU SystemsUser Manual
80-30200000-031-2
1.3 The SBU14C
The SBU14C fits into a standard 19” cabinet system. There are
positions for 14 cards in all, including the SBUGSM or SBULSM.
Cooling is provided for the shelf by fans in the PSUs. If only one or two
PSUs are fitted, then PSU blank panels must be fitted to the empty slots.
An illustration of the layout of the SBU14C and the flow of cooling air
through it, is shown in Figure 1:-
A
A
Fans Air flow
Front
(Application)
Card
Rear
(Interface)
Card
IEC
Connector
Section through ‘AA’
PSU
FIVEMERE FIVEMERE FIVEMERE
Figure 1 SBU14C
Each power inlet individually feeds each power supply module.

Scope and Introduction
80-30200000-03 1-3
1.4 The SBU6C
The SBU6C is designed to be either a ‘Desk Top’ unit, a ‘Tower’ unit
under a desk, or a shelf mounted unit In a standard 19” cabinet (by the
addition of mounting ‘ears’).
There are positions for 6 cards in all, including the SBUGSM or
SBULSM.
When operating in ‘Desk Top’ or ‘Tower’ modes, plastic feet are supplied
on the relevant face of the enclosure.
Cooling is provided by a permanently installed fan (
i.e.
not in the PSUs).
An illustration of the layout of the SBU6C is shown in Figure 2:-
A
AFan
Air
Front
(Application)
Cards
Rear
(Interface)
Cards
Section
through
‘AA’
PSUs
Acrylic
Cover
IEC
Mains
Inlet
Air
Figure 2 SBU6C
Each power inlet individually feeds each power supply module.

Installation and Cabling
80-30200000-03 2-1
2. Installation and Cabling
The SBU14C is a high density rack mounted unit designed to sit in a 19"
communications cabinet. It has eight fixing points, four down each side
of the front of the frame. All eight fixing points must be securely fixed to
the frame.
The SBU6C can be rack mounted by the addition of rack mounting ears.
The ears must be securely fixed to the frame.
2.1 Mains Input and Wiring
On the rear of the unit there are three IEC mains sockets (for SBU14C)
or two IEC mains sockets (for SBU6C) for connection to independent
mains supplies. The primary earth connection is made via these
sockets.
WARNING - these appliances must be earthed.
VORSICHT - Nur eine vorschriftsmäßig geerdete Steckdose
anschließen.
Mains cables, 2 metres in length are supplied with both units. These
should be connected to a suitable mains supply. The mains plug is the
primary disconnect device for the unit. Ensure that the unit is installed
near to socket outlets and that the outlets are easily accessible.
The mains cables supplied with the unit are fitted with moulded 13 amp
plugs for connection to standard socket outlets. Should the plugs not be
of the correct type for the outlets that they are connected to, the plugs
This manual suits for next models
1
Table of contents
Popular Computer Hardware manuals by other brands

EMC2
EMC2 VNX Series Hardware Information Guide

Panasonic
Panasonic DV0PM20105 Operation manual

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 user manual

Gigabyte
Gigabyte B660M DS3H AX DDR4 user manual

Raidon
Raidon iT2300 Quick installation guide

National Instruments
National Instruments PXI-8186 user manual