Note: All power connections to be installed to
local/national codes by a Certified Electrician.
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com
1
Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732
HP-4 Wall Mo nt Indirect
Joiner/Ender Installation Instructions
© 2017 FI ELITE, I C. ALL RIGHTS RESERVED. Form 98197 V2. 04/17
Step 1
Remove joiner Top Glow™ diffuser and set aside to
prevent it from getting dirty or damaged. NOTE: If part
of a longer run, diffuser will be reinstalled back into
original luminaire se ction as lengths vary.
Starter
Joiner/Ender
#8-18 x 1/2" Combo
Hex Screws (provided)
Step 6
Remove trap door #8-18 x 1/4" screws (provided) to open
trap door. Install #8-18 x 1/2" combo hex screws
(provided) into end brackets. CAUTION: Do not
over-tighten.
6"6"
Luminaire Length
Minus 6"
Luminaire Length
Minus 6"
Luminaire Length
Starter Joiner Ender
Wall Rail
Point A Wall Rail
Center of the Rail
Step 2
Position wall rails as indicated above. Center of mounting rail for starter is 6" from Point A as indicated on the Starter/Independent installation instructions (step 3A and 3B).
Make sure wall rail has proper backing (by others).
Level wall rail to ensure proper mounting. Install
#10 screws (by others) through rail and into
backing.
Step 3
Aligner Sleeve
Plug Together Wiring
Starter
Joiner/Ender
Step 4
Connect plug-together wiring. Slide starter and joiner/ender luminaires together.
0 - 10V
Dimming
Scan QR code for
helpf l video(s)
Wall Bracket (Top Hook)
Wall Bracket (Bottom Hook)
Wall Rail
Luminaire
Wall
Step 5
Position the luminaire in place and slide the wall bracket
straight down to engage top top and bottom hooks of the
wall bracket into the wall rail. Be careful not to damage
any wiring.